PHONE (800) 875-5285

step by step

Installation Step 1

Step 1 - Materials and Tools

Assemble for a fault free installation:

* WarmlyYours floor warming roll(s) of mesh backed cable
* Thermostat with sensor
* Digital Ohm meter
* Circuit Checkā„¢ (sold separately)
* Scissors
* Staple gun, hot glue gun or dry wall tape

Installation Step 2

Step 2 - Cuts and Turns

Cut the fiberglass mesh roll with scissors to create "panels". Position the panels around fixtures using cuts and turns to accommodate the system design lay out. Use the custom floor plans where provided. NEVER cut the warming cable; cut the mesh only.

Installation Step 3

Step 3 - System Installation

Staple or glue the panels to the sub floor, install the floor sensor and apply a 1/8" layer of thinset or self leveling cement over top of the mesh.

Installation Step 4

Step 4 - Flooring Installation

For a one step process, install the floor covering directly over the cement embedded system using an additional layer of thinset cement. Alternatively, allow the first layer to cure before installing the tile with a second layer of thinset for a two step process.

Installation Step 5

Step 5 - Electrical Hook Up

The system can then be wired to the home electrical system and the thermostat installed in a standard 4"x 4" wall box by a licensed, certified electrician.