TCT120-3.7W-300 Frequently Asked Questions

Don't see the answer you're looking for? Post your question

How do I work with my electrician to install WarmlyYours electric floor heating?

While WarmlyYours electric radiant floor heating systems are typically installed by your floor covering contractor, a licensed electrician is recommended for the final thermostat hook-up. With every quote, we provide an Installation Plan layout, together with an electrical plan that has all the info required for the electrician.

35 people found this helpful.  Did you find this helpful? Yes No

How can I determine what I need for my floor heating project and how can I find out what my floor heating system will cost?

You can use the Instant Quote Tool, which gives you many options for your floor heating coverage. Use this interactive tool to design your room online and receive an instant quotation with product recommendations, rough-in and installation kits, cost of your control, etc. Planning your floor heating project is made easy when using our Instant Quote Tool.

Send us your floor plan or fax it to (800) 408-1100 and we will send you a quote, product recommendation and a free custom installation plan for your project.

29 people found this helpful.  Did you find this helpful? Yes No

What voltage does WarmlyYours floor heating systems utilize?

The floor heating systems are offered in both 120 volt and 240 volt for the North American market. A 208 volt breaker panel can also accommodate our 240 volt floor heating system. It is important to note that the energy consumption will be the same: a 240 volt system will not cost more to operate than a 120 volt system. You are billed in kilowatts, and the 120 volt and 240 volt systems use the same amount of kilowatts. WarmlyYours often specifies a 120 volt system in smaller projects while a 240 volt system is typically recommended for larger projects (120 square feet of electric floor heating coverage or more). The benefit of switching to a 240 volt system is the reduction in amperage. Our programmable thermostat can control a radiant floor system up to 15 amps. The 120 volt system will reach 15 amps at 120 square feet of electric floor heating coverage. However, the 240 volt system will reach 15 amps at 240 square feet of electric floor heating coverage, allowing a much larger system to be connected to the thermostat. For installations over 240 square feet, a relay contactor or power modules are needed.

22 people found this helpful.  Did you find this helpful? Yes No

Is electric floor heating safe and what about EMF?

Our electric radiant floor heating systems have withstood rigorous safety testing and earned the UL listing. They produce much less EMF than common household appliances like your TV or vacuum cleaner. The EPRI (Electric Power Research Institute) tests all electrical devices and publishes the data. Many common household appliances are tested at a distance of 6 inches. The test results indicate that on average, the EMF emitted for the following appliances, measured in Milligauss (mG) units, is:

Vacuum Cleaner: 300 mG

Microwave: 200 mG

Portable Heater: 100 mG

Dishwasher: 20 mG

Washing Machine: 20 mG

WarmlyYours TempZone™ (Twin): 1.8 mG

26 people found this helpful.  Did you find this helpful? Yes No

What type of flooring can I install along with an electric floor heating system?

WarmlyYours’ TempZone™ product is most commonly installed under tile, stone, and marble flooring, but can also be installed under many other popular floor covering options such as hardwood, vinyl and linoleum. We also have our Environ system, which is an electric floor heating product as well and is specially designed for installation under carpet (in the U.S. only), laminate and floating wood. WarmlyYours can accommodate any flooring type with either of the electric radiant floor heating products that we offer. If your flooring type isn't listed here, just give us a call at (800) 875-5285 and we will be happy to discuss it with you.

24 people found this helpful.  Did you find this helpful? Yes No

If I have extra cold lead wire, can I trim off what I don't need for my installation?

Yes. Unlike the heating cable for electric floor heating, the cold lead wires can be trimmed.

18 people found this helpful.  Did you find this helpful? Yes No

How do you keep a sunroom warm in the winter?

Sunrooms can be very cold during the winter months. While a furnace may push some warm air into the room, the large number of windows, exterior walls, and other causes of heat loss in a sunroom will typically keep it from having a comfortable temperature level. Floor heating and radiant panels will add radiant heat, which the human body absorbs faster than other forms of heat, to the room so that it feels warm even at lower temperatures.

17 people found this helpful.  Did you find this helpful? Yes No

Should I be concerned about electric floor heating melting the toilet connection's wax ring?

To prevent any melting, ensure that the heating wire is at least 4” from the toilet wax ring.

13 people found this helpful.  Did you find this helpful? Yes No

Can electric floor heating be installed under a vanity?

Electric radiant floor heating should not be installed under permanent fixtures that may trap heat. However, if the vanity or cabinets are "floating" or are on legs, then a floor heating system may be installed under it.

13 people found this helpful.  Did you find this helpful? Yes No

Can I put furniture on top of underfloor heating?

Yes, but any furniture that may trap heat, such as pieces with an enclosed bottom, should be avoided. Furniture on legs with a clearance of at least 3" is permissible.

13 people found this helpful.  Did you find this helpful? Yes No

How do I know if I am installing my electric floor heating system properly?

Please keep in mind that you must check your electric floor heating system with a digital ohmmeter in conjunction with a Circuit Check™. Take an initial reading as soon as you take the product out of the box to verify that it is within -5% / +10% of the values stated on the product’s label. This will give you a basis of comparison for future readings. Take a second reading once you have positioned the system to match your custom installation plan. It is also advisable to take an additional reading in the middle of the tile installation, just to make sure that the Circuit Check™ is doing its job. Then, take a final reading when you are finished with the floor installation and are ready to hook up the thermostat.

The Circuit Check™ is a tool developed by WarmlyYours to give you peace of mind and ensure trouble-free installations. Simply hook up the cold leads to the tool while you position the system to match your custom installation plan.

The Circuit Check™ will continuously monitor the continuity of the circuit during the installation of your system and during the installation of your flooring. The Circuit Check™ beeps immediately when a short in the system is detected, alerting you to a potentially damaged cable in the area you are working, before you lay the tile over the electric floor heating system.
 The WarmlyYours technical support team is available 24/7 to provide assistance if the alarm sounds, or if you would have any questions during your installation.

12 people found this helpful.  Did you find this helpful? Yes No

Should I add insulation before installing electric floor heating and how will that affect the system's performance?

When installing electric floor heating over a concrete slab, an insulating underlayment like ThermalSheet is highly recommended to ensure efficient operation, faster heating times and warmer floor temperatures.

12 people found this helpful.  Did you find this helpful? Yes No

What temperature should I set my heated floor to?

The perfect room or floor temperature is always going to be a personal preference. However, we do see that our customers will usually set their floor temperature to somewhere in the 80°F to 84°F range.

12 people found this helpful.  Did you find this helpful? Yes No

How much does it cost to run an electric floor heating system?

The answer to this question will depend on a whole host of variables related to electric floor heating, including, but not limited to, the run time (for supplemental heating, we usually recommend between 4-8 hours per day), the electric radiant floor heating system you're using, the total square footage, and your local electrical cost. Typically, the cost is just a few cents a day. 

To figure out how much electric floor heating might cost to run for you, make sure to use our interactive Operating Cost Calculator. 

11 people found this helpful.  Did you find this helpful? Yes No

Do I need insulation when installing an electric floor heating system over a concrete slab?

When WarmlyYours electric floor heating systems are being installed on a concrete slab, we strongly recommend adding a layer of insulation over the slab prior to installing the system. While our electric floor heating provides up to 25% more heating power per square foot than many of our competitors, the slab will always act as a "heat sink." Some of the heat that would otherwise be transferred to the flooring surface will remain in the slab, causing the floor’s surface temperature to be considerably lower. This is true with any electric radiant floor heating system.

When installed on top of a concrete slab without insulation, it is generally accepted that electric floor heating will take the chill away from the floor and provide a small amount of warmth. Adding insulation on top of the slab and beneath any electric radiant floor heating system will allow a greater percentage of the heat generated to transfer to the flooring surface. This results in greater efficiency and therefore faster warm up times, higher expected surface temperatures and lower energy usage. The floor will have the capacity to warm to a comfortable temperature, and in some cases can be employed as the primary heat source for that room.

The recommended types of insulation are natural cork, insulated tile backer boards and insulated underlayment, such as ThermalSheet™ synthetic cork.

10 people found this helpful.  Did you find this helpful? Yes No

Will electric floor heating help with moisture issues like mold and mildew?

Yes, the drying effects of electric radiant floor heating will reduce the humidity coming from the slab, which is the largest source of moisture.

9 people found this helpful.  Did you find this helpful? Yes No

Can you heat under the appliances, fixtures, or furniture in a laundry room, mudroom, or utility room?

No, it is recommended that floor heating only be installed in the areas that you will walk on. Heat can become trapped if installed under objects that do not offer enough clearance for air to circulate (such as a washer or dryer).

9 people found this helpful.  Did you find this helpful? Yes No

Do radiant heating products have polarity?

Electric-resistance heating cables and systems have no polarity. This includes all current WarmlyYours heating elements.

9 people found this helpful.  Did you find this helpful? Yes No

What type of floor preparation is required for Luxury Vinyl Tile (LVT) and radiant heating?

The subfloor will need to be prepared as per the instructions of the self-leveling cement (SLC) used. Please note that most self-leveling products require the use of a primer as specified by the SLC company.

9 people found this helpful.  Did you find this helpful? Yes No

Can I use electric floor heating as a primary heat source?

Yes, in most cases, an electric floor heating system can be effective as a primary heat source. However, our TempZone™ and Environ™ systems are most commonly used as a secondary heat source, providing floor-to-ceiling radiant heat to any room in your home where you desire more warmth and comfort.

If you are considering electric floor heating for an addition to your home, such as a sunroom where you have no other source of heat, WarmlyYours offers an innovative online tool which calculates approximate heat loss. This tool can help you to determine if a WarmlyYours’ electric radiant floor heating system will provide your desired comfort temperature throughout the year. You can access the Heat Loss Calculator or you can call us at (800) 875-5285 and a Customer Service Representative will make the calculation for you.

8 people found this helpful.  Did you find this helpful? Yes No

Will the radiant heat affect the attached rubber or cork backing on Luxury Vinyl Tile? Does the attached backing have any effect on the floor heating system?

Since most Luxury Vinyl Tile (LVT) manufacturer's set a maximum temperature for radiant floor heating, the system should have little to no effect on the rubber/cork backing.

Pre-attached backing can act as an insulating layer though, meaning it can prevent the radiant heating from efficiently directing heat up through the floor. Please check with the manufacturer for the r-value of the product. Look for an assembled plank with an r-value of less than 1. The lower the r-value, the better!

8 people found this helpful.  Did you find this helpful? Yes No

Do I have to replace my floor to install electric floor heating?

Yes. While there are some floor heating systems that can be installed beneath floor joists, most electric radiant floor heating systems will need to be installed beneath the floor itself. This is why the best time to install electric floor heating is during a remodel or as a part of a new construction, when a floor is being installed anyways. 

If you're interested in alternative radiant heating methods, check out our Radiant Panels, which are wall-mounted and use infrared technology to provide supplemental heating. 

7 people found this helpful.  Did you find this helpful? Yes No

How are hydronic and electric floor heating systems different?

While both hydronic (heated water) and electric floor heating systems perform a similar function by providing radiant heat from beneath your floor, they do differ in some pretty crucial ways. Typically, using hot water instead of electricity will result in lower operational costs but significantly higher investment and maintenance costs. This usually means that hydronic heating systems are reserved for new construction projects (where it is easier to incorporate the boilers and pumps needed to operate the system) and electric floor heating is often used for remodeling projects in bathrooms, kitchens, etc. To learn more about the differences between these systems, check out this post

7 people found this helpful.  Did you find this helpful? Yes No

How much does it cost to heat a bathroom floor with electric floor heating?

A typical bathroom floor can be heated for about a quarter a day with electric radiant floor heating.

7 people found this helpful.  Did you find this helpful? Yes No

What is a good choice, or watt density, for supplemental heat?

Supplemental heat can be addressed by changing the spacing on cable installs. Floor location in the house is very important when considering adding supplemental heating to a floor. For example: If heating a second story floor, over a heated space, cable at 4" spacing can be used. The same type of heating over an unheated space would probably be done with TempZone Flex Rolls or TempZone Cable at 3" spacing. All heating is considered supplemental unless a heat loss calculation is done.

7 people found this helpful.  Did you find this helpful? Yes No

How can I make my basement warmer?

A floor heating system can work as a supplemental heating source and make the basement warmer. If more heat needs to be added to the room, you can experiment with setting the floor heating thermostat to higher temperatures.

6 people found this helpful.  Did you find this helpful? Yes No

Can I heat luxury vinyl tile/planks in the kitchen?

Yes, our TempZone Heating Products can be used for heating luxury vinyl tile or luxury vinyl planks in any indoor application.

6 people found this helpful.  Did you find this helpful? Yes No

What breaker and wire size do I need to use for a floor heating system?

The breaker and wire sizes are selected based on the total amperage of the WarmlyYours heating system connected to a single thermostat. This information is on the WarmlyYours heating system's installation plan, electrical plan, or UL label. Based on guidelines from the National Electrical Code: loads up to 16 Amps may utilize 12 gauge wire with a 20-Amp breaker, and loads up to 12 Amps - 14 gauge wire with a 15-Amp breaker. Local code and/or other factors may change these guidelines.

6 people found this helpful.  Did you find this helpful? Yes No

Will the flooring manufacturer still warrant with electric floor heating underneath?

Always check with the flooring manufacturer to see what they will cover when it comes to floor heating. In most cases there will be a floor temperature limit - this can be programmed into a programmable or smart thermostat. Check for installation instructions and requirements before adding floor heating.

6 people found this helpful.  Did you find this helpful? Yes No

Do I need to apply a layer of thinset over the subfloor first?

Yes, using a square-notch trowel (1/4” x 1/4” or larger), apply a layer of thinset to the subfloor area which will later be covered by the WarmlyYours TempZone™ Flex Roll, Easy Mat or Custom Mat.

5 people found this helpful.  Did you find this helpful? Yes No

How does electric floor heating work?

Electric floor heating works by having an electric heating cable installed underneath the flooring (embedded or floating, depending on the system and floor type), which is then wired to a special thermostat (either one specifically designed for electric radiant floor heating, like a WarmlyYours’ nSpiration Series control, or a third-party thermostat). When turned on, the heating cable emits heat upward through the flooring which is then radiated throughout the room, heating all solid surfaces. 

5 people found this helpful.  Did you find this helpful? Yes No

Is the TempZone™ floor heating system safe?

Yes. The WarmlyYours TempZone™ floor heating system has withstood rigorous safety testing by the Underwriter's Laboratory and has received UL listing for the U.S. as well cUL certification for Canada. WarmlyYours offers thermostats that carry the CSA Mark and the UL listing, which certifies that the product has been tested under extreme conditions and meets applicable standards for safety and/or performance in the U.S. and Canada. All WarmlyYours thermostats contain a Ground Fault Circuit Interrupter (GFCI) which provides fail-safe protection against an electrical shock.

5 people found this helpful.  Did you find this helpful? Yes No

What temperature will my heated floor reach?

The temperature of your floor can range anywhere between 75°F to 95°F. The floor's actual temperature will depend on a number of factors including the amount of heat loss that the room experiences as well as the room’s configuration. For instance, the warmth contained in a two story entry way would likely be less than that of a smaller, more enclosed area such as a bathroom. In a bathroom that is located on the second floor of your home or over another floor in your home that is typically heated, the temperature of your heated floor should easily reach a comfortable temperature of 85 degrees Fahrenheit, if the electric floor heating system is installed correctly. For the heat loss calculation for your specific room, you can access the Heat Loss Calculator or you can call us at (800) 875-5285 and a Customer Service Representative will make the calculation for you.

4 people found this helpful.  Did you find this helpful? Yes No

How will electric floor heating affect my wood floor?

WarmlyYours nSpiration controls are equipped with an in-floor sensor to precisely control the floor's temperature to comply with the wood manufacturer's temperature recommendation.

4 people found this helpful.  Did you find this helpful? Yes No

What is the maximum temperature for Luxury Vinyl Tile (LVT) when it comes to in-floor heating?

This is stated in the Installation Manual of the LVT product when purchased. On average, this maximum temperature will fall between 80°F and 83°F. This number can then be used to program the thermostat during setup to set the floor's maximum temperature.

4 people found this helpful.  Did you find this helpful? Yes No

What is the warranty for the TempZone™ floor heating system? Do you warrant the cost of replacing the flooring installed on top of the system? What if there was a surge that damaged the system?

WarmlyYours’ 25-Year No Nonsense™ Warranty is the most comprehensive warranty in the industry. In the event of a defect, we cover not only the repair or replacement of the TempZone™ system, but ALSO any labor costs AND flooring materials required to perform the repair. We do not cover the cost of flooring that needs to be replaced in the event of a repair necessitated due to damage. If a product is damaged by a power surge, that would not be covered by our warranty

4 people found this helpful.  Did you find this helpful? Yes No

How many square feet of floor heating can be connected to one thermostat?

One thermostat can control multiple heating mats/cables as long as all the heating elements are using less than 15 amps:

TempZone™ will cover aprx. 120 sq. ft. for 120V systems and 240 sq. ft. for 240V systems on one thermostat.

Environ™ will cover aprx. 150 sq. ft. for 120V systems and 300 sq. ft. for 240V systems on one thermostat.

Slab Heat will cover aprx. 90 sq. ft. for 120V systems and 180 sq. ft. for 240V systems on one thermostat.

4 people found this helpful.  Did you find this helpful? Yes No

I have too much / too little of the TempZone™ product for the space I want to heat. Can I trim or add more heating cable?

No. Never cut the heating cable. The floor heating cable is designed with a very specific resistance in order to consistently maintain heating at the chosen wattage per square foot. Trimming the heating cable would lower the resistance of the cable causing the system to overheat. Adding heating cable to the system would raise the resistance and the system would not heat properly.

3 people found this helpful.  Did you find this helpful? Yes No

How can I make my room warmer without a heater?

Floor heating will typically add the most heat to supplement an existing heating source and it will not take any extra space since it is embedded in the floor. If you are not remodeling your floors but have some open wall space, you should mount a radiant panel. For the most effective results, install the panel so that it points toward the area where you will spend most of the time.

3 people found this helpful.  Did you find this helpful? Yes No

How does electric floor heating compare to central or forced air heating?

Typically, electric floor heating is used as a supplemental heat source but in some cases, it can be used as a primary heat source. Electric floor heating is more energy efficient, less prone to spreading dust and allergens, and easier to control from room to room. Air-based heating systems can be used for both heating and cooling and can be a good way to control air quality in the home with regular maintenance. 

For a more in-depth answer to this question, check out Your ‘Cheat Sheet’ for Radiant Heat vs. Forced Air

3 people found this helpful.  Did you find this helpful? Yes No

What is the typical operating cost of a TempZone™ floor heating system?

The actual cost of operating your floor heating system will vary depending upon a number of factors including the cost of electricity in your area and the length of time you run your system. The WarmlyYours TempZone™ Flex Roll electric floor heating system, for example, uses 15 watts per square foot. Based on a national average electricity rate of $.10/kW/hr, the approximate operating cost of an average bathroom using this system, measuring 8' x 10' would be between $.16 - $.21 cents a day. This cost is based on running your system a full 8 hours per day. Try our Operating Cost Calculator for a quick estimate.

3 people found this helpful.  Did you find this helpful? Yes No

Does the heat cause any shrinkage, expansion, or warping of the vinyl flooring?

If the flooring manufacturer has a warranty for electric floor heating, it should not be adversely affected by shrinkage, expansion, or warping. Again, it will depend on the brand and construction of the product. Some manufacturers may place limitations on the maximum floor heating temperature. To minimize expansion and contraction, some Luxury Vinyl Tile companies require heating the flooring to a continuous heating level with "setback" temperatures (lower temperature settings during the day and overnight) kept to a minimum.

While radiant heating can affect the expansion and contraction of the floor, the most overlooked and important factor is the relative humidity in the space, so a humidifier or dehumidifier may be needed.

3 people found this helpful.  Did you find this helpful? Yes No

How effective are radiant electric floor under 3/4" wood flooring?

For best results, we recommend a 1”- 1.5” maximum distance between the heating cable and the top of the floor. Nailed down hardwood will require sleepers to run the cable safely between board nails. Be sure to use 3/8" to 3/4" of self-leveling cement to embed the heating element.

3 people found this helpful.  Did you find this helpful? Yes No

Would the TempZone installation process be different if Luxury Vinyl Tile was installed in a bathroom?

No. A bathroom floor would be installed in the same way. Our TempZone floor heating systems are wet-location listed and ideal for bathroom floors.

3 people found this helpful.  Did you find this helpful? Yes No

Do you have a separate thermostat for the shower?

Bathrooms designed with shower and floor heating will include only one thermostat by default. But it is possible to design with a thermostat for each zone if desired. Installing a separate thermostat for the shower area can help reduce cost and energy usage. This also allows you to heat the bathroom floor alone for everyday use and only heat the shower area when needed.

3 people found this helpful.  Did you find this helpful? Yes No

Is a filler needed on the rest of the floor to space the flooring up to the same level?

The TempZone™ twin conductor cable present in our TempZone™ products is comprised of a double-insulated, coaxial heating cable. The total thickness of the system can be between ⅛” and 5/32” thick and will not noticeably affect the height of your installed flooring. The heating system is encased in 3/8" of modified thinset or Self leveling underlayment. You simply use that 3/8" layer throughout the space, eliminating any need for fillers.

3 people found this helpful.  Did you find this helpful? Yes No

Can this floor heating be used under an existing hardwood floor?

No, most in-floor heating is designed to be added to new flooring. If you do have existing wood floors you would like to add radiant heating to - it is possible to do so with an under-joist heating system. 

3 people found this helpful.  Did you find this helpful? Yes No

Is installing a floor heating system for LVT the same as for ceramic or porcelain tile?

Yes, Luxury Vinyl Tile (LVT) is typically installed over the embedded heating element using self-leveling cement (SLC). Many people choose to use SLC when installing tile over floor heating.

We do not suggest using thinset to encase the heating wires with LVT, as it is very difficult to get thinset completely flat.

3 people found this helpful.  Did you find this helpful? Yes No

Can the floor heating be set to turn on at certain times when we know we will use those areas and need heating?

Yes, with our programmable thermostats, you can choose which days and times the floor heating turns on for your comfort. With a Smart thermostat, you can also control these options from your phone while away from home.

2 people found this helpful.  Did you find this helpful? Yes No

Is the heating element waterproof?

Our TempZone electric floor heating products are waterproof and wet location listed.

2 people found this helpful.  Did you find this helpful? Yes No

What if I have cracks in my concrete slab? Will that affect the floor heating installation?

Make sure any cracks or raised edges are sanded down before installation. Seal and patch cracks where possible. If needed, pour a layer of self-leveling cement to make sure surface is level and flat. Then proceed with instructions to install desired floor heating system and flooring.


It is strongly recommended that an insulating underlayment be installed between the slab and heating element to prevent heat loss.

2 people found this helpful.  Did you find this helpful? Yes No

What is the WarmlyYours TempZone™ floor heating system?

TempZone™ is an electric floor heating system that operates like an electric blanket for your floors. TempZone™ is covered in thin-set or Self-Leveling Underlayment, and is installed over the top of your subfloor and beneath your flooring. The system provides a warm, even temperature across your floor, generating floor-to-ceiling radiant warmth to transform these naturally cold surfaces into warm floors. Ideal for kitchens, bathrooms or any room in your home where you would enjoy radiant warmth and comfort, the TempZone™ floor heating system is easy to install, operate and maintain.

2 people found this helpful.  Did you find this helpful? Yes No

What thickness is required for self-leveling cement when installing floor heating for Luxury Vinyl Tile?

We suggest the heating product be embedded in a minimum of 3/8" of self-leveling cement (SLC). Always check with the manufacturer for specific recommendations.

2 people found this helpful.  Did you find this helpful? Yes No

Which LVT, WPC or Solid Core product can be paired with electric radiant floor heating? Is there a list of manufacturers who still provide a warranty when pairing with radiant floor heating?

LVT (Luxury Vinyl Tile), WPC (Wood Plastic Composite), and Solid Core all fall into the category of "vinyl flooring." These vinyl flooring types can be rated for floor heating, but the application will completely depend on the manufacturer's guidelines.
Please look in the installation manual and warranty documents of the LVT, WPC, and Solid Core flooring product that you are interested in to see if and what types of heating are allowed.

As for a list of manufacturers of LVT, WPC, and Solid Core products providing a warranty for their products with radiant heat -- many do provide a warranty for their products when properly installed with floor heating. The list of these is ever-changing, so please be sure to check with the flooring manufacturer for current recommendations.

2 people found this helpful.  Did you find this helpful? Yes No

Can I put electric floor heating in the shower?

Yes. In addition to TempZone™ and Slab Heat, we also have specially sized Shower and Bench mats designed specifically for shower installation. They are all wet location listed for radiant floor heating in a shower.

2 people found this helpful.  Did you find this helpful? Yes No

Can this heating system be installed over Solid Polymer Core (SPC) floor or a Wood Plastic Composite (WPC) Luxury Vinyl Tile (LVT) floor?

We suggest removing SPC or WPC flooring before installing the floor heating system over it if possible. If that is not practical, use an underlayment designed specifically for covering these types of floors. Radiant heating can be used with many types of these floors, but check with the flooring manufacturer to confirm that it can be paired with these types of systems.

2 people found this helpful.  Did you find this helpful? Yes No

Is the waterproofing above or below the heating wire?

Waterproofing for the room is in the layer above the floor heating system. The layers for waterproofing this type of floor are:

  • subfloor
  • thinset
  • uncoupling membrane
  • tempzone heating cable
  • waterproofing tape for seams and corners
  • thinset or self leveling cement
  • tile floor
2 people found this helpful.  Did you find this helpful? Yes No

What wood species are recommended or not for floor heating? Is Engineered or solid better? Nailed down or floating?

The most important factor for the wood floor chosen is structural stability.

According to the USDA Forest Service, this list shows most dimensionally stable to least: 

  • Mesquite 
  • Australian Cypress 
  • Teak 
  • Santos Mahogany
  • American Cherry
  • South Yellow Pine 
  • Douglas Fir 
  • American Walnut 
  • Brazilian Cherry 
  • Hard Maple 
  • Red Oak 
  • True Hickory
  • American Beech

Engineered is the most structurally stable compared to natural hardwood, so it will work the best with floor heating.
If you do want to go with Hardwood, quartersawn or riftsawn narrow planks are the most structurally stable and would work best for this application.

Overall the most important factor for the room is relative humidity. Keeping a consistent humidity and temperature in the home will help wood floors last for many years to come.

    2 people found this helpful.  Did you find this helpful? Yes No

    What should I do with the floor sensor that was included with my floor heating element?

    WarmlyYours has recently begun including floor sensors with our heating elements to help ensure customers will have everything they need for optimal operation of their radiant heating systems.

    The sensor included with your floor heating element can be installed with the heating system (the sensor is equally spaced between runs of the heating wire--see your install manual for more info). Installing this sensor with your floor heating control will enable energy efficient operation of the floor warming system based on the floor temperature instead of the ambient room temperature.

    We generally recommend that you install a second, unconnected backup floor sensor alongside the primary one. In the very unlikely event that your first floor sensor is damaged, this install method will save you from having to pry up flooring to replace a floor sensor. You simply disconnect the damaged sensor from the thermostat and connect the backup sensor.

    In addition to the floor sensor that was included with your heating element, our nSpiration Series thermostats also come with a floor sensor. If you purchase both a heating element and an nSpiration Series thermostat from WarmlyYours, you'll have a primary and a backup floor sensor for your system.

    2 people found this helpful.  Did you find this helpful? Yes No

    Does this system work with Cork Flooring?

    Cork flooring can be used with floor heating if the r-value is under 1. You will need to find the r-value of the flooring you choose and let your account manager know during the design stage. Cork flooring should have a low r-value to minimize trapped heat.

    2 people found this helpful.  Did you find this helpful? Yes No

    How many watts per square foot does TempZone™ deliver?

    The TempZone™ Flex Rolls, Easy Mats and Shower Mats are designed to deliver 15 watts per square foot (maximum allowed by the National Electrical Code), with the heating element positioned 3” apart on a serpentine loop attached to a fiber mesh. The TempZone™ Cable yields between 8-12 watts per square foot, variable, based on the cable spacing. TempZone™ Custom Mats are made to order, so the spacing of the heating element throughout the mat varies according to each specific design. The TempZone™ Custom Mats can yield from 12 to 15 watts per square foot.

    1 person found this helpful.  Did you find this helpful? Yes No

    Can you use a sunroom in the winter?

    Yes, sunrooms can be used in the winter, just activate your floor heating or radiant panel and turn your sunroom into a 4-season room. You will notice a tremendous difference in the room comfort, especially with the thermostat set to maintain a desired ambient temperature. WarmlyYours thermostats will do the work for you by energizing the floor for longer cycles.

    1 person found this helpful.  Did you find this helpful? Yes No

    Can you use glue-down Luxury Vinyl Tile products with this floor heating system?

    Yes, if the flooring manufacturer recommends this installation method. In most cases, the heating element will still need to be embedded in self-leveling cement before the flooring is installed.

    1 person found this helpful.  Did you find this helpful? Yes No

    Is there a way to heat vinyl flooring without embedding the heating system, such as a floating floor heating system?

    There are heating systems designed for floating floors, such as our Environ system. However, the flooring must be rigid enough so it does not mold itself to the heating cables over time.

    Check the flooring manufacturer's floor heating recommendations. In most cases, the heating system will need to be embedded beneath the flooring. Check for all "flatness" requirements for the flooring you choose. The flattest floors utilize self-leveling cement when installed correctly.

    1 person found this helpful.  Did you find this helpful? Yes No

    Will the installation of a TempZone™ floor heating system affect the height of my floor?

    The TempZone™ twin conductor cable present in our TempZone™ products is comprised of a double-insulated, coaxial heating cable. The total thickness of the system can be between ⅛” and 5/32” thick and will not noticeably affect the height of your installed flooring.

    1 person found this helpful.  Did you find this helpful? Yes No

    What is the recommended temperature for a heated kitchen floor?

    Everyone has their own comfortable temperature setting, but we typically find that our customers use their thermostats to set the "floor temperature" of the system in the 78°F - 84°F range.

    1 person found this helpful.  Did you find this helpful? Yes No

    Should you leave underfloor heating on all the time?

    An electric underfloor heating system doesn't need to be left on all the time. The system can be completely turned off or set back to a lower temperature when not in use. If you have a programmable floor heating thermostat, then the system can also be set to operate only during specific times.

    1 person found this helpful.  Did you find this helpful? Yes No

    Can I have one thermostat for my open floor kitchen, dining room and living room?

    We usually recommend that you have an individual thermostat for each room. However, if it's an open floor plan and your local electrical code allows you to have one controller for the whole area, then it's definitely possible to have it all controlled from one thermostat.

    1 person found this helpful.  Did you find this helpful? Yes No

    What should I consider if I want to heat a vinyl or composite material floor?

    We recommend verifying 3 things with the manufacturer of the flooring product to be heated;

    1.) Is the flooring product compatible with electric floor heating?

    2.) What is the maximum temperature the flooring product can withstand?

    3.) What is the temperature set back recommendation of the flooring product?

    1 person found this helpful.  Did you find this helpful? Yes No

    Can the floor be waterproofed and still have floor heating?

    Yes, we offer several options to help make your floor heating system water resistant or waterproof. Our TempZone product line is designed for wet areas - making it completely safe for rooms that will have water on the floor at times or may experience leaks or flooding. We also offer waterproofing bands for our TempZone Cable + Prodeso Uncoupling Membrane system. Allowing you to waterproof all seams and the perimeters of the wall - guaranteeing that your floor heating system stays safe and prevents water from leaking to areas below.

    Did you find this helpful? Yes No

    How do I prepare my living room for extreme cold?

    Having floor heating installed and set to a higher temperature during particularly cold days will help to maintain a comfortable temperature level by providing supplemental heat.

    Did you find this helpful? Yes No

    How can I make my living room feel warmer?

    Simply set your floor heating thermostat to a comfortable temperature to maintain a nice warm floor. Your room will feel warmer and, typically, your furnace will cycle less often.

    Did you find this helpful? Yes No

    What is the BTU output of these systems?

    For Tempzone it is 51 BTU’s per square foot per hour and for Environ, it is 41. Take the wattage of the product (shown on the product’s label) and multiply that by 3.41. That is the BTU value for that product.

    Did you find this helpful? Yes No

    Can I use the floor heat with LVT?

    Yes, we recommend using the Tempzone system encased in ⅜“-½“ of self-leveling cement followed by LVT.

    Did you find this helpful? Yes No

    Can the TempZone™ heating wire be shortened?

    It cannot be shortened, and all TempZone™ heating cable must be used at appropriate spacing.

    Did you find this helpful? Yes No

    Can you install multiple sensors in the floor for one thermostat?

    Yes, you can install multiple sensors while installing the floor heating system. Only one of these sensors should be connected to the floor heating thermostat. Any secondary sensors can be run through conduit up to the thermostat area to be connected in the future should anything happen to the original sensor. The sensor is low voltage and may not need conduit. If conduit is required, it will need to be separate from the return power leads.

    Did you find this helpful? Yes No

    Can you install this over existing ceramic tile floor?

    In some cases it is possible to install embedded electric floor heating over existing tile floor. You will need to check with your flooring manufacturer to see what requirements they have for the subfloor. Once you have that information, we can make a recommendation on whether floor heating will work for your project. A specific type of thinset may be needed for this application. In most cases you will need to repair or replace damaged existing tiles. They should then be scuffed or sanded, and then cleaned. After these steps have been completed, the new tile could be installed using the appropriate thinset.

    Did you find this helpful? Yes No

    Can you walk directly on the matting to pour the self leveling cement (SLC) or should you lay plywood to protect the mats since spiked shows are often used with SLC ?

    Do not wear spiked shoes when installing SLC. When installing, you can walk on the wires, but not the factory splices. Minimize traffic on exposed wires and wear soft-soled shoes when working over the wire.

    Did you find this helpful? Yes No

    Does a floor heating system require a separate GFCI breaker, and if so, what amperage?

    A Warmly Yours indoor floor heating system should not be installed with a GFCI breaker because GFCI protection is built into the thermostat and power module.  And while it's not always required, we strongly recommend a dedicated circuit for each thermostat and power module to limit the occurrence of ground fault nuisance tripping caused by multiple GFCI devices on a circuit. The amperage of a breaker would depend on the amp draw of the heating system. For example, a TempZone Flex Roll (which provides approximately 15 watts of energy output per square foot) that is providing 15 square feet of heating coverage will draw only 225 watts ( 1.9 Amps), so a 15 Amp circuit would suffice.  Always size breakers according to your local Electrical Code requirements. 

    Did you find this helpful? Yes No

    In regard to heavy or large objects on the floor, how should floor heating be planned to accommodate these?

    An area where large furniture will cover the floor should have enough clearance underneath to allow air to circulate. Any areas where floor heat may be trapped (rugs, box bottom furniture), let your sales rep know so we can design an installation plan around these areas.

    Did you find this helpful? Yes No

    What is the cost of TempZone Cable heating elements?

    Pricing for TempZone Cable heating product typically starts at $6 per sq. ft. ($7 CAD) when installed with Fixing Strips and $9 per sq. ft. ($11 CAD) when installed with our Prodeso Cable Installation Membrane. 

    Did you find this helpful? Yes No

    What is the maximum tile thickness for this system?

    For best results, we recommend a 1”- 1.5” maximum distance between the heating cable and the top of the floor. Depending on your thinset or self-leveling cement thickness, this will leave roughly an inch or less for maximum tile thickness.

    Did you find this helpful? Yes No

    What is the spacing of wire for TempZone™ radiant heating mats and cable?

    Spacing is 3“ wire to wire.  Spacing when the wire installed in Prodeso installation membrane is 3.75“

    Did you find this helpful? Yes No

    What is the total power/amperage that the TempZone electric floor heating system draws and does this system need a dedicated circuit?

    The amount of amperage draw depends upon how large the area is that you are heating. For coverage of areas less than 30 square feet, a 120V TempZone system will draw less than 4 amps. If you have a larger area over 240 square feet of heated space, then you will need a larger breaker plus additional controls. No matter what the size of the area you choose to heat, we recommend a dedicated circuit for your electric radiant floor heating system.

    Did you find this helpful? Yes No

    What type of thin set is used to embed the Tempzone in?

    Latex, polymer or acrylic modified.

    Did you find this helpful? Yes No

    What’s the difference between hydronic (heated water tubing) and electric floor heating?

    Hydronic systems operate by using heated water pumped through tubing beneath the floor. Electric underfloor heating works with heated cables beneath the floor. Typically, hydronic systems are a good choice for new construction projects and electric systems are better for remodels or single rooms. This is because the high installation costs of hydronic systems (boilers, pumps, etc.) makes them cost-prohibitive for projects like a bathroom or kitchen. Electric radiant heating systems are also easier to repair than hydronic systems if they're damaged. 

    For a more complete answer to this question, check out this blogpost

    Did you find this helpful? Yes No

    Where to connect the ground wire of floor mats/cables?

    The ground wire in the floor mat must be connected directly to the ground wire of the supply or to the house ground wire.

    Did you find this helpful? Yes No

    Why not develop a heated floor solution for any type of floor rather than specific type of floor?

    There is a way to install floor heating that makes it suitable for any type of floor. By embedding our TempZone systems in self-leveling cement (SLC), you have created a heated subfloor. Almost any low r-value flooring can be installed directly over this for heated floors.

    Did you find this helpful? Yes No