TempZone™ Floor Heating Cable 120V, (3.7W/ft.), 30 ft., 1.0A
How Much Cable Will I Need?
| Coverage (sq. ft.) Based on Cable Spacing | ||||||
|---|---|---|---|---|---|---|
| Length | Voltage | 3" | 3.5" | 3.75" | 4" | 5" |
| 30′ | 120 | 7.5 | 8.8 | 9.4 | 10 | 12.5 |
| 40′ | 120 | 10 | 11.7 | 12.5 | 13.3 | 16.7 |
| 50′ | 120 | 12.5 | 14.6 | 15.6 | 16.7 | 20.8 |
| 55′ | 240 | 13.8 | 16 | 17.2 | 18.3 | 22.9 |
| 65′ | 240 | 16.3 | 19 | 20.3 | 21.7 | 27.1 |
| 70′ | 120 | 17.5 | 20.4 | 21.9 | 23.3 | 29.2 |
| 75′ | 240 | 18.8 | 21.9 | 23.4 | 25 | 31.3 |
| 90′ | 120 | 22.5 | 26.3 | 28.1 | 30 | 37.5 |
| 95′ | 240 | 23.8 | 27.7 | 29.7 | 31.7 | 39.6 |
| 115′ | 240 | 28.8 | 33.5 | 35.9 | 38.3 | 47.9 |
| 120′ | 120 | 30 | 35 | 37.5 | 40 | 50 |
| 150′ | 120 | 37.5 | 43.8 | 46.9 | 50 | 62.5 |
| 155′ | 240 | 38.8 | 45.2 | 48.4 | 51.7 | 64.6 |
| 180′ | 120 | 45 | 52.5 | 56.3 | 60 | 75 |
| 195′ | 240 | 48.8 | 56.9 | 60.9 | 65 | 81.3 |
| 220′ | 120 | 55 | 64.2 | 68.8 | 73.3 | 91.7 |
| 235′ | 240 | 58.8 | 68.5 | 73.4 | 78.3 | 97.9 |
| 260′ | 120 | 65 | 75.8 | 81.3 | 86.7 | 108.3 |
| 275′ | 240 | 68.8 | 80.2 | 85.9 | 91.7 | 114.6 |
| 300′ | 120 | 75 | 87.5 | 93.8 | 100 | 125 |
| 315′ | 240 | 78.8 | 91.9 | 98.4 | 105 | 131.3 |
| 340′ | 120 | 85 | 99.2 | 106.3 | 113.3 | 141.7 |
| 355′ | 240 | 88.8 | 103.5 | 110.9 | 118.3 | 147.9 |
| 375′ | 120 | 93.8 | 109.4 | 117.2 | 125 | 156.3 |
| 395′ | 240 | 98.8 | 115.2 | 123.4 | 131.7 | 164.6 |
| 432′ | 120 | 108 | 126 | 135 | 144 | 180 |
| 435′ | 240 | 108.8 | 126.9 | 135.9 | 145 | 181.3 |
| 515′ | 240 | 128.8 | 150.2 | 160.9 | 171.7 | 214.6 |
| 595′ | 240 | 148.8 | 173.5 | 185.9 | 198.3 | 247.9 |
| 675′ | 240 | 168.8 | 196.9 | 210.9 | 225 | 281.3 |
| 749′ | 240 | 187.3 | 218.5 | 234.1 | 249.7 | 312.1 |
| 864′ | 240 | 216 | 252 | 270 | 288 | 360 |
The amount of cable you'll need depends on the heat output and amount of heating coverage you want, both of which are impacted by the spacing of the heating cable. The spacing of the heating elements is dictated by how the cable is installed and WarmlyYours offers two different installation methods: with Fixing Strips or with our Prodeso Membrane.
Fixing Strips
An economical option, requires more work than the membrane.
Ideal spacing for installing TempZone 3.7-watt Cable:
- 3" (14.8-watts per sq. ft.)
Other spacing options:
- 4" (11.1-watts per sq. ft.)
- 5" (8.88-watts per sq. ft.)
Prodeso Membrane
Costlier than strips, speeds up installation and provides uncoupling benefits
Ideal spacing for installing TempZone 3.7-watt Cable:
- 3.75" (11.84-watts per sq. ft.)
Other spacing options:
- 5" (8.88-watts per sq. ft.)
You can use our quote tool to get a rough estimate of the amount of cable you'll need for a project.
Or contact us for help:
You can also submit a drawing of your project (with dimensions) and we'll provide you with a free installation plan with the exact amount of cable you'll need. Get started
Features
-
25 Year Warranty
-
9-15 Watts Per Sq. Ft
-
Loose cable offers the freedom and flexibility to fit any room shape
TempZone™ Cable Description
WarmlyYours TempZone™ Floor Heating Cable (Twin) brings radiant warmth and comfort to any room. This free-form cable provides the ultimate in flexibility, making it easy to customize installation for rooms of any size and shape.
While ideally suited to provide complete floor heating coverage of rooms with unusual dimensions, the TempZone™ Floor Heating Cable (Twin) can be used in any room, providing an alternative for installers who prefer the flexibility and freedom of working with loose cable.
Specifications
Electrical
| Amps | 1.08 A |
| Cold Lead Wire Gauge | 17 AWG |
| Floor Load | 0.13 kW |
| Ohms | 111 Ω |
| Ohms Per Ft | 3.7 Ohm/ft |
| Thermal Power | 0.13 kW |
| Voltage | 120 V |
| Watts | 130 W |
| Watts Per Sq. Ft at 3.75 Inch Spacing | Up to 12 |
| Watts Per Sq. Ft. | 9 to 15 |
| Watts Per Sq. Ft. at 3 Inch Spacing | Up to 15 |
| Watts Per Sq. Ft. at 4 Inch Spacing | Up to 11 |
| Watts Per Sq. Ft. at 5 Inch Spacing | Up to 9 |
Warranty / Certifications
| Approvals | cULus listed |
| Warranty | 25 Year Warranty |
| Wet Location Listed | US, Canada |
Performance
| BTU Per Hour | 444 Btu |
Product Dimensions
| Cold Lead Length | 15′ |
| Coverage | 10 ft² |
| Coverage at 3 Inch Spacing | 7.5 ft² |
| Coverage at 3.5 Inch Spacing | 8.8 ft² |
| Coverage at 3.75 Inch Spacing | 9.4 ft² |
| Coverage at 4 Inch Spacing | 10 ft² |
| Coverage at 5 Inch Spacing | 12.5 ft² |
| Heating Element Thickness | 3/16″ |
| Length | 30′ |
| Weight | 1.8 lbs |
Appearance
| Color | Red |
Installation
Logistics
| Package Contents | (1) TempZone Floor Heating Cable 120V 3.7W/ft 30 ft 1.0A (TCT120-3.7W-030); 1x Floor Heating Sensor (FH-BACKUP-SENSOR) |
| UNSPSC Code | 40101830 |
Identifiers
| SKU | TCT120-3.7W-030 |
| UPC (GTIN-12) | 881308048969 |