Contact Us After Hours

Loading...

Loading contact options...

Sign In

Loading...

Loading...

Roof and gutter deicing power connection kit components: cable gland, locknut, O-ring, mounting bracket, wire nuts, end cap, braided sleeve, heat shrink tubes and grounding wire

Roof and Gutter Heat Tape Accessories

A roof and gutter deicing installation needs four things beyond the cable: a power connection kit, aluminum roof clips, double-sided gutter pads to bond those clips down, and a control with a moisture sensor to switch the system on.

Ordering them with the system is the simplest part of preparing for winter.

Essential Roof Heat Tape Accessories Checklist

Everything a self-regulating deicing run needs beyond the cable itself.

Power Connection Kit One per cable run. The SR-PWR-KIT hardwires the run; the SR-PLUG-KIT gives you a ground-fault-protected plug-in instead. Both include the ET-END-KIT end seal.
Aluminum Roof Clips Gutter heating cable clips hold the cable to shingle and metal roofs — roughly 1 clip per 10 feet of gutter, plus 2 for each downspout.
Gutter Pads & Primer 3" x 2" VHB pads bond the clips to the roof above 50°F. Add ET-94-PRIMER on rubber, EPDM and other surfaces that resist adhesion.

Roof Heat Tape Power Connection Kits

Ground-fault-protected plug-in and hardwired power kits for ET-SR cables. One kit is required per cable run, and each includes an ET-END-KIT end seal.

Plug-in GFCI power connection kit for self-regulating heating cable, including power cord, inline GFCI module, and installation hardware.

The SR-PLUG-KIT Ground‑Fault‑Protected Plug‑In Kit (part #JSR08) includes materials for plug‑in installation of roof and gutter deicing systems. The kit provides ground‑fault protection and is cULus Listed for 120V ET‑SR series cables. The SR‑PLUG‑KIT supports 15A and is designed for use with cables up to 107 feet. An ET‑END‑KIT (part #JSR12) is included.


  • Plug-in conversion kit with GFCI protection for compatible 120 V ET-SR or PT-SR self-regulating heating cable.
  • Includes an end-termination kit; one kit is required for each independent cable run.
  • cULus Listed for the specified 120 V cable systems.
Power connection kit and end seal components for roof and gutter de-icing systems, including conduit connectors, wire nuts, and grounding braid.

The SR‑PWR‑KIT Power Connection Kit (part #JSR00) includes materials needed for hardwired installations of roof and gutter deicing systems. The SR‑PWR‑KIT is cULus Listed and is suitable for use with ET‑SR series cables. An ET‑END‑KIT (part #JSR12) is included. One required for each individual run of cable.


  • Hardwired power connection kit for self-regulating Ice Shield roof/gutter or PRO-Tect pipe protection cable.
  • Includes a JSR12 end-seal termination kit.
  • One kit is required for each independent section of self-regulating heating cable.

Gutter Pads, Clips & Adhesives

Gutter heating cable clips, double-sided gutter pads and primer for mounting self-regulating cable to roofs and gutters.

Double-sided VHB tape pads for securing roof and gutter heating cables.

These double‑sided tape pads are used to affix aluminum clips to roof and gutters.


  • 3" x 2" pads
  • 25 pads per package
  • ET‑94‑PRIMER may be needed for sufficient adhesion on some surfaces (refer to primer description for details)
  • Install when temperature is above 50° F for best results
A 1-quart metal can of 3M 94 Primer used as an adhesive promoter for VHB tape applications.

Required for use on rubber, EPDM, and some other surfaces to promote adhesion of VHB tape pads. 1‑quart container.


  • Primer for VHB tape pads used to install roof and gutter deicing cable.
  • For VHB-pad adhesion on rubber, EPDM and other specified surfaces.
  • Supplied in a one-quart container.
Three aluminum 3-prong roof clips for securing self-regulating heating cables to a roof surface.

Ideal for attaching self‑regulating deicing cable to typical roof and gutter surfaces, such as metal and asphalt shingle.


  • 25 clips per package
  • Use ET‑VHB‑PAD‑P25 double‑sided tape pads to affix clips to roof
  • Typical installation recommendations: Gutters — 1 clip per 10 feet of gutter, plus 2 for each downspout; Roofs — 5 clips per triangle in zigzag installation pattern

Frequently Asked Questions

Showing all 6 questions

No.  Aluminum 3-prong clips can cause rapid galvanic corrosion if they come in direct contact with copper.  WarmlyYours recommends using our Self-Regulating roof & gutter cable fastened with 3-prong Copper clips (ET-CL-CU-P25) and double-sided adhesive pads (ET-VHB-PAD-P25) for this application.

Was this helpful?

Aluminum 3-prong clips ship 25 to a package. For gutters, allow one clip per 10 feet of gutter, plus two for each downspout. For roofs, allow five clips per triangle in the zigzag layout. Each clip is affixed to the surface with an ET-VHB-PAD-P25 double-sided pad.

Was this helpful?

Yes. Both the SR-PWR-KIT and the SR-PLUG-KIT include an ET-END-KIT end seal. Self-regulating cable is cut to length on site, so the cut end has to be sealed against moisture. You need one connection kit, and therefore one end seal, for each individual run of cable.

Was this helpful?

Both connect an ET-SR self-regulating cable to power, and both include an ET-END-KIT end seal. The SR-PWR-KIT is for a hardwired connection. The SR-PLUG-KIT converts the run to a ground-fault-protected 120V plug-in instead, rated for 15A. You need one kit for each individual run of cable.

Was this helpful?

Install when the temperature is above 50°F for best results. The 3” x 2” double-sided pads bond the aluminum clips to the roof or gutter and ship 25 to a package. Below that temperature the adhesive will not reach full strength, so fit the pads before the first hard freeze.

Was this helpful?

Use it wherever the VHB tape pads will not bond reliably on their own: rubber, EPDM, and certain other surfaces. The primer is applied before the pad and is sold in a 1-quart container. On typical asphalt shingle and metal roofs the pads bond without it.

Was this helpful?