Contact Us Open

Loading...

Loading contact options...

Sign In

Loading...

Loading...

Roof & Gutter Deicing for Roofers

Roof & Gutter Deicing for Roofers

Stop Ice Dams Before They Start

Ice dams cause billions in property damage every year. Offer roof and gutter deicing as a premium add-on during re-roofing jobs—and open a recurring revenue stream.

WarmlyYours provides self-regulating deicing cables for metal, asphalt shingle, and slate roofs, backed by trade pricing, free SmartPlan™ layouts, and 24/7 technical support.

Request a Quote Deicing Products

Request a Roof & Gutter Heat Tape Quote

Tell us about the roof and our engineers will prepare a no-obligation quote, SmartPlan™ and electrical plan.

Have these ready

  • Total eave length and overhang depth
  • Total gutter length
  • Number and height of downspouts
  • Available voltage: 120V, 208V, 240V or 277V
  • A sketch of the roofline, gutters, downspouts, valleys and power source

Prefer paper? Download the quotation form (PDF) | Or call (800) 875-5285

What Roofers Are Saying

We take pride in providing both exceptional service and great products. But don't just take our word for it, check out what some of our customers have had to say.

Self-Regulating vs. Constant Wattage Cable

Two cable systems: ICE Shield kits for simple residential jobs, and ICE Shield self-regulating cable for complex professional installs. Here's when to quote each.

ICE Shield constant wattage cable compared with ICE Shield self-regulating cable
Feature ICE Shield
Constant Wattage
ICE Shield
Self-Regulating
Heating technology Fixed-resistance constant wattage Conductive polymer core that adjusts to temperature
Heat output Fixed at 5 W/ft 5–10 W/ft, rising as the temperature drops
Voltage 120V only 120V, 208V, 240V or 277V
Format Pre-assembled kits, 20–240 ft Spools from 50' to 1,000', cut to length on-site
Cutting & overlapping Never cut or overlap it — it overheats and burns out Cut to exact length and safe to overlap
Max run per circuit 240 ft 540 ft at 240V, 589 ft at 277V
Installation DIY plug-in with a 6 ft cold lead and 3-prong plug Professional hardwired, or a plug-in kit up to 140 ft at 120V
Controls Manual, timer or outlet Automatic panels with ambient and moisture sensors
Operating cost Runs at 100% whenever it is on Cuts power as the temperature rises
Upfront cost Lower Higher
Best for Small-to-medium residential eaves, gutters and downspouts Complex rooflines, valleys, commercial and large residential

Choose ICE Shield Plug-In Heat Tape Kit when

  • The roof is asphalt shingle with simple eaves, standard gutters and straight downspouts
  • The homeowner wants the lowest upfront cost
  • Power is an existing 120V outdoor GFCI outlet
  • Every run fits a pre-assembled 20–240 ft kit without cutting or overlapping

Quote ICE Shield (Self-Regulating) when

  • The roof is metal, standing seam or rubber/EPDM — constant wattage is prohibited there
  • Valleys, dormers, multi-level gutters or narrow downspouts mean the cable has to overlap
  • The job is commercial or large residential, on 208V, 240V or 277V circuits
  • You need to cut cable to exact field lengths
  • The client wants automatic sensor control that cuts power as it warms up

Cable Type by Roof Material

The roof material decides which cable you can install. Check it before you quote.

Metal, standing seam, steel and rubber/EPDM roofs require self-regulating cable (ICE Shield). Constant wattage cable is prohibited on them. On conductive metal it creates localized heat traps and a fire risk, and the UL-listed installation method requires self-regulating cable — installed any other way, there is no listing and no warranty.
Which deicing cable each roof material allows, how to fasten it, and what to watch for
Roof material ICE Shield
Constant Wattage
ICE Shield
Self-Regulating
Fastening Installation note
Metal / Standing Seam / Steel Prohibited Required Standing-seam clamps or adhesive clips Never penetrate the seams. Constant wattage creates localized heat traps on conductive metal.
Rubber / EPDM / Flat Membrane Prohibited Required Adhesive clips on double-sided tape pads over primer Zero roof penetrations. Clean the membrane with solvent and prime it before mounting clips.
Asphalt / Fiberglass Shingle Permitted Permitted Aluminum 3-prong clips under the shingle tabs Seal nails and screws with outdoor-grade roofing sealant. Keep constant wattage loops at least 3" apart.
Slate / Concrete or Clay Tile Not recommended Recommended Tile adhesive or bracket hangers under the tile overlap Never nail or screw through tile or slate. Cushion the cable where it crosses sharp edges.
Cedar Shake / Wood Shingle Not recommended Recommended Adhesive pads or stainless steel clips under the shakes Self-regulating cable avoids hot spots on combustible wood.
Gutters & Downspouts Permitted Permitted Clips inside the gutter every 10 ft, plus one before and after each downspout Where the cable must overlap, as in narrow downspouts, only self-regulating cable is safe.

Fastening details, tracing patterns, circuit sizing and code requirements for every material are in the field guide.

Download the Technical PRO Guide: Installation by Material (PDF)

The Pro Newsletter

Monthly field guide to radiant profit, tech, and trends — straight from the WarmlyYours team.

Ready to Offer Roof Deicing?

Register as a trade professional to unlock exclusive deicing benefits:

Trade pricing on all deicing products
Free SmartPlan deicing layouts
24/7 technical support
Same-day shipping, no minimums
Progressive discounts up to 35%
50 sq ft free showroom display
Questions? Contact Us

We respond within 1 business day | (800) 875-5285

Roofer FAQ

Showing all 9 questions

Yes! WarmlyYours offers certification courses for trade professionals who want to enhance their expertise in radiant heating installation.

Our certification program covers:

  • Product knowledge for all WarmlyYours product lines
  • Installation best practices and techniques
  • Testing procedures and troubleshooting
  • Thermostat programming and controls

Benefits of certification:

  • Official certification credential for your business
  • Listed in our installer referral network
  • Increased customer confidence
  • Access to advanced technical resources

Courses are available online and can be completed at your own pace. Visit the Courses page to get started.

Was this helpful? Yes No

WarmlyYours products are installed by various trades depending on the product line:

Floor Heating (TempZone™, Environ™)

  • Tile contractors – install heating elements during tile installation
  • Flooring installers – Environ system for floating floors
  • Electricians – handle electrical connections and thermostat wiring

Snow Melting Systems

  • Concrete/paving contractors – embed cables during pour
  • Electricians – controls and power connections
  • Landscapers – for paver installations

Roof & Gutter Deicing

  • Roofers – cable routing and attachment
  • Electricians – power connections and controls

Towel Warmers & Infrared Heating Panels

  • Electricians – hardwired installations
  • General contractors – plug-in models require no electrical work

Pipe Freeze Protection

  • Plumbers – cable installation on pipes
  • Electricians – power connections
Was this helpful? Yes No

Yes. Self-regulating de-icing cable can be installed on asphalt shingle, metal, membrane, tile, and wood roofs, and inside metal or vinyl gutters and downspouts. Mounting clips and attachment methods vary by surface, so tell us the roof type when you request your layout and we will specify the right hardware.

Was this helpful? Yes No

Yes. Roof and gutter de-icing cable must run on a dedicated GFCI-protected circuit sized for the total cable wattage, installed by a licensed electrician. Long roof edges and gutter runs often require more than one circuit, which is why we size circuits for you on every SmartPlan™ layout.

Was this helpful? Yes No

Yes. Send us your roof dimensions, gutter and downspout lengths, and eave overhang and our team prepares a free SmartPlan™ layout showing cable runs, footage, circuit sizing, and controls. Trade partners get the plan plus a quote at trade pricing, usually within one business day.

Was this helpful? Yes No

Register free at our For Professionals page to unlock trade pricing on all roof and gutter de-icing cable, panels, and controls. There are no fees, no purchase minimums, and no annual volume requirement — pricing applies from your first order.

Was this helpful? Yes No

De-icing cable is not meant to clear the whole roof. It creates drainage channels through ice at the eaves, in valleys, and inside gutters and downspouts, so meltwater escapes instead of backing up under shingles. That is what prevents ice dams and the leaks and gutter damage they cause.

Was this helpful? Yes No

Trade partners get 24/7 technical support from radiant heating experts, free SmartPlan™ layouts, same-day shipping with no order minimums, and certification courses. Call our support line from the roof if you hit a question mid-install — there is no charge and no ticket queue.

Was this helpful? Yes No

WarmlyYours offers self-regulating and constant-wattage heating cable for roof edges, valleys, gutters, and downspouts, plus low-voltage heated roof panels for problem ice-dam areas. Cables are paired with automatic aerial ice sensors or manual controls. See our roof and gutter de-icing systems.

Was this helpful? Yes No