WarmlyYours Ice Shield Roof and Gutter Deicing Cable Kit, Plug-in, 120V (80')

5.00
Based on 11 reviews



Support Page

Features

  • This 80' cable is recommended for use in medium projects like a 17’ gutter with 12" of roof overhang coverage and a 10’ downspout

  • Includes: heating cable, clips, and spacers

  • DIY-friendly with plug-in operation (no additional controls required)

  • 5 watts per linear foot (constant wattage)

  • Safe: cUL Listed, CSA Listed, and cETLus Listed

Ice Shield: DIY Roof and Gutter Deicing Kit: Constant Wattage Description

Product Details:

One of the leading causes of roof and gutter damage is degradation caused by the formation of ice dams during winter. These harmful accumulations can wreak havoc on your roof or gutters, leading to leaks, loss of property value, and even costly replacements.

Save yourself the headache by installing a DIY-friendly Ice Shield: Roof and Gutter Deicing Kit from WarmlyYours. The 120 V constant-wattage (5 watts per linear foot) heating cables will prevent damage to your roof and gutters all winter long. These kits include everything you’ll need for an easy and safe installation.

Features: 

  • Recommended for medium projects like a 17’ gutter with 12" of roof overhang coverage and a 10’ downspout
  • Includes: heating cable, clips, and spacers
  • DIY-friendly with plug-in operation (no additional controls required)
  • 5 watts per linear foot (constant wattage)
  • Safe: cUL Listed, CSA Listed, and cETLus Listed
  • Covered by a 2-year warranty

Specifications

Electrical

Amps 3.33 A
Cable Construction Twin conductor
Cable Type Constant Wattage
Conductor Insulation XLPE
Connection Method Plug-in
Ohms 36.04 Ω
Outer Insulation PVC
Plug-Type NEMA 5-15 (Type B)
Plug-in Cord Length 6′
Voltage 120 V
Watts 400 W
Watts Per Ft. 5 W

Warranty / Certifications

Approvals cUL Listed, CSA Listed, and cETLus Listed
Warranty 2 Year Warranty

Product Dimensions

Cable Cross Section 1/4" x 3/16"
Cold Lead Length 6′
Heating Cable Length 80′
Height 0.1875″
Length 960″
Weight 3.6 lbs
Width 0.25″

Installation

Minimum Bend Radius 1″
Minimum Installation Temperature 15°F (-10°C)

Identifiers

SKU ETC120-5W-080-WY
UPC (GTIN-12) 881308053901

Frequently Asked Questions

Electric-resistance heating cables and systems have no polarity. This includes all current WarmlyYours heating elements.

14 people found this helpful.  Did you find this helpful? Yes No

Our self-regulating heating product is designed to be cut to length at the jobsite by an installer where it can then be end-capped with accessories (sold separately).
However, our constant wattage kits contain heating elements that cannot be shortened or altered in any way.

12 people found this helpful.  Did you find this helpful? Yes No

GFEP is the National Electric Code (NEC) required protection for fixed outdoor deicing and snow-melting equipment, which may be accomplished by using circuit breakers equipped with ground-fault equipment protection (GFEP) of 30 mA. It is important to understand that this required equipment protection is NOT the same as a 5 mA GFCI used for personal protection.

10 people found this helpful.  Did you find this helpful? Yes No

We do not recommend leaving the cable on all year long. It's an unnecessary use of energy to run the cable during warm weather and it could actually cause the heating cables to overheat if they're left on during very warm weather. 

7 people found this helpful.  Did you find this helpful? Yes No

 Cable length needed depends on the sizes and areas of the roof that need to be deiced (roof with gutter, downspouts, valleys, and/or dormers). Our best recommendation is for you to give us a call (1-800-875-5285) and we can help you identify what measurements will need to be taken. Alternatively, you can
measure the dimensions of the aforementioned areas and refer to the installation manual to get an idea of how much cable you'll need. 

6 people found this helpful.  Did you find this helpful? Yes No