Can TempZone or Environ non-heating leads be shortened?


Distinguish a trimmable non-heating power lead from the heating cable.

Yes. The non-heating cold leads may be shortened as permitted by the instructions for the exact TempZone or Environ product. The heating cable itself must not be cut or shortened.

  • The TempZone Flex Roll manual permits shortening its cold lead.
  • The TempZone Cable manual permits trimming excess cold lead and recommends leaving 12 inches extending from the thermostat box for the connection.
  • The Environ sell sheet explicitly permits shortening only the non-heating cold leads, not the warming roll or heating wire.

Have a qualified electrician make electrical connections in accordance with the product instructions and applicable codes. Keep the heating cable and factory connection intact.

Sources: TempZone Flex Roll manual (PDF page 5), TempZone Cable manual (section 2.1.10), and Environ sell sheet (page 2).