TC-MEM-BL-BND-0624 Frequently Asked Questions

Don't see the answer you're looking for? Post your question

Frequently Asked Questions

Showing all 6 questions

The height of the membrane itself is just about 1/4" (7/32").

3 people found this helpful Was this helpful? Yes No

This membrane provides many benefits including speedy installation, uncoupling, crack isolation, vapor management, and load distribution.

1 person found this helpful Was this helpful? Yes No

1.25"

1 person found this helpful Was this helpful? Yes No

No, the tile floor should be installed at the same time as the embedding of the heating cable. 

Was this helpful? Yes No

No, the Prodeso Cable Installation Membrane does NOT eliminate the need for movement joints, including perimeter joints, within the tiled surface.

Was this helpful? Yes No

The most common spacing is 3.75" (3 membrane nodules) between runs of heating cable. Occasionally, systems will be designed with 5" spacing (4 membrane nodules). 

Was this helpful? Yes No