TempZone Flex Roll Kit 1.5 x 52 ft (78 sqft) with nTrust 2.0 Touch Nonprogrammable Thermostat, 120V, 9.75A




Request a Free Product Sample
Support Page

TempZone Flex Roll Kits with nTrust 2.0 LED Touch Thermostat Description

Specifications

Electrical (TRT120-1.5x52)

Amps 9.75 A
Cold Lead Wire Gauge 14 AWG
Floor Load 1.17 kW
Ohms 12.31 Ω
Ohms Per Ft 0.041 Ohm/ft
Thermal Power 1.17 kW
VOP 61
Voltage 120 V
Watts 1170 W
Watts Per Sq. Ft. 15 Watts Per Sq. Ft.

Warranty / Certifications (TRT120-1.5x52)

Approvals cULus listed
Warranty 25 Year Warranty
Wet Location Listed US, Canada

Warranty / Certifications (UTN5-4999)

Approvals cULus listed
Ingress Protection (IPxx) Rating IP20
Warranty Limited 3-year warranty and lifetime technical support

Performance (TRT120-1.5x52)

BTU Per Hour 3992 Btu

Electrical (UTN5-4999)

Battery 5 year battery backup of clock and calendar
Connection 4 wires, double pole
Connection Method Hardwired
Ground Fault Protection GFCI, Class A, 5 mA
Maximum Current 15 A
Maximum Power 1800 W @ 120 V, 3120 W @ 208 V, 3600 W @ 240 V
Supply 120 VAC, 208 VAC, 240 VAC (50/60Hz)

Product Dimensions (TRT120-1.5x52)

Cold Lead Length 15′
Coverage 78 ft²
Heating Cable Length 303.34′
Heating Element Thickness 1/8″
Length 52′
Weight 8.6 lbs
Width 1′ 6″

Appearance (TRT120-1.5x52)

Color Green

Appearance (UTN5-4999)

Color White Acrylic
Display LED Light Through

Product Dimensions (UTN5-4999)

Depth 1.73″
Installed Depth 0.46″
Length 4.98″
Weight 0.6 lbs
Width 3.09″

Thermostat (UTN5-4999)

Floor Sensor Compatibility 10k ohms or 12k ohms
Includes Floor Sensor 10k ohms, 15′ lead
Maximum Ambient Temperature Setting 77 °F
Maximum Floor Temperature Setting 104 °F
Minimum Ambient Temperature Setting 32 °F
Minimum Floor Temperature Setting 41 °F

Installation (TRT120-1.5x52)

Floor Types Tile, Marble, Stone, Vinyl, LVT, LVP, Wood, Bamboo, Carpet, and more

Logistics (TRT120-1.5x52)

Package Contents (1) TempZone Flex Roll 120V 1.5′ x 52′ 78 sq ft 9.8A (TRT120-1.5x52); 1x Floor Heating Sensor (FH-BACKUP-SENSOR)
UNSPSC Code 40101830

Identifiers (TRT120-1.5x52)

SKU TRT120-1.5x52
UPC (GTIN-12) 881308021429

Identifiers (UTN5-4999)

SKU UTN5-4999
UPC (GTIN-12) 881308080426

Frequently Asked Questions

Showing all 5 questions

Our electric radiant floor heating systems have withstood rigorous safety testing and earned the UL listing. They produce much less EMF than common household appliances like your TV or vacuum cleaner. The EPRI (Electric Power Research Institute) tests all electrical devices and publishes the data. Many common household appliances are tested at a distance of 6 inches. The test results indicate that on average, the EMF emitted for the following appliances, measured in Milligauss (mG) units, is:

Vacuum Cleaner: 300 mG

Microwave: 200 mG

Portable Heater: 100 mG

Dishwasher: 20 mG

Washing Machine: 20 mG

WarmlyYours TempZone™ (Twin): 1.8 mG

32 people found this helpful Was this helpful? Yes No

Yes. Unlike the heating cable for electric floor heating, the cold lead wires can be trimmed.

22 people found this helpful Was this helpful? Yes No

Since most Luxury Vinyl Tile (LVT) manufacturer's set a maximum temperature for radiant floor heating, the system should have little to no effect on the rubber/cork backing.

Pre-attached backing can act as an insulating layer though, meaning it can prevent the radiant heating from efficiently directing heat up through the floor. Please check with the manufacturer for the r-value of the product. Look for an assembled plank with an r-value of less than 1. The lower the r-value, the better!

8 people found this helpful Was this helpful? Yes No

The breaker and wire sizes are selected based on the total amperage of the WarmlyYours heating system connected to a single thermostat. This information is on the WarmlyYours heating system's installation plan, electrical plan, or UL label. Based on guidelines from the National Electrical Code: loads up to 16 Amps may utilize 12 gauge wire with a 20-Amp breaker, and loads up to 12 Amps - 14 gauge wire with a 15-Amp breaker. Local code and/or other factors may change these guidelines.

6 people found this helpful Was this helpful? Yes No

Yes, using a square-notch trowel (1/4” x 1/4” or larger), apply a layer of thinset to the subfloor area which will later be covered by the WarmlyYours TempZone™ Flex Roll, Easy Mat or Custom Mat.

5 people found this helpful Was this helpful? Yes No

Customer Reviews