Medium Relay Panel, (4x) 2-Pole



Numbers of poles

Support Page

Features

  • Comes with 8 poles (four 2-pole pairs)

  • Each of the 4 relays in the RLY-8PL-CC are rated for up to 30 Amps

  • Designed for use with snow melting, slab heating, and roof and gutter deicing systems

  • Safe: cULus approved and NEMA 1-rated metal enclosure

  • Limited 2-year warranty

Relay Panels Description

These quiet, load-switching panels are ideally suited forsnow melting cables and mats, as well as slab heating and roof deicingapplications. Each of the 4 relays in the medium-sized RLY-8PL-CC are rated for up to 30 amps, and housed in NEMA 1 indoorenclosures, and designed for use with 120, 208, 240 or 277 VAC cables. Allcomponents of the RLY-8PL-CC mediumrelay panels are cULus approved. Comes with 8 poles (four 2-pole pairs) and easy-to-use “push-in” terminals for connecting the leads and power supply.

Specifications

Electrical

Applicable Voltages 120 V, 208 V, 240 V, 277 V
Connection Method Hardwired
Maximum Current 30 A
Numbers of Poles 8

Warranty / Certifications

Approvals cULus listed
Warranty 2 years
Waterproofing NEMA 1

Product Dimensions

Depth 4″
Height 12½″
Weight 10 lbs
Width 10½″

Identifiers

SKU RLY-8PL-CC
UPC (GTIN-12) 881308065386

Frequently Asked Questions

Showing all 5 questions

GFEP is the National Electric Code (NEC) required protection for fixed outdoor deicing and snow-melting equipment, which may be accomplished by using circuit breakers equipped with ground-fault equipment protection (GFEP) of 30 mA. It is important to understand that this required equipment protection is NOT the same as a 5 mA GFCI used for personal protection.

11 people found this helpful Was this helpful? Yes No

The relay panel is not rated for outdoors.  It can be put in a NEMA 4 box outdoors to meet this requirement.

Was this helpful? Yes No

Our systems can handle low temperatures, but many controls come equipped with a Low-Temperature Lockout Feature. This feature prevents the system from running in very low temperatures. At very low temperatures it can become difficult for the system to effectively melt the snow. It is however possible to turn off this feature should you need the system to keep running during such low temperatures.

14 people found this helpful Was this helpful? Yes No

All of our automatic controllers have a Hold-on time feature after the initial warming up of the snow melt system. This feature ensures that all the snow is melted from the surface, and also that the system continues to operate and evaporate the surface water without it refreezing.

9 people found this helpful Was this helpful? Yes No

When the design requirement's amp draw exceeds the selected controller's capacity.

5 people found this helpful Was this helpful? Yes No