PRO-Tect Plug-In Heat Tape for Pipes — 3 ft, 7 W/ft, 120V




Support Page

Features

  • This 3' cable is great for 3/8“ – 3/4“ diameter pipes up to 5’ long and 1” – 1 1/2” diameter pipes up to 3’ long

  • Easy plug-in operation with indicator light and integrated thermostat

  • Stops pipes from freezing at temps as low as -40°F/-40°C

  • 7 watts per linear foot (constant wattage)

  • Safe: cUL Listed, CSA Listed, and cETLus Listed

PRO-Tect Plug-In Heat Tape for Pipes Description

A burst water pipe in the dead of winter can be a huge inconvenience and completely replacing the insulation needed to prevent pipes in perimeter walls and crawlspaces from freezing can be cost-prohibitive.

To keep your most vulnerable pipes from freezing, the simple and DIY-friendly solution is to install a PRO-Tect heating cable for pipes. This 3' long 120 V plug-in heating cable generates heat (7 watts per linear foot) which will keep your pipes from freezing in low temperatures. The integrated thermostat control, located between the non-heating lead cable and the heating wire itself, will ensure a consistent temperature while minimizing energy use. The thermostat turns the heating cable on when exposed to temperatures below 37.4°F (3°C). It will shut the heating cable off when the pipe has been heated to a temperature of approximately 50°F (10°C).

Features: 

  • This 3' cable is great for 3/8” – 3/4" diameter pipes up to 5’ long and 1” – 1 1/2” diameter pipes up to 3’ long
  • DIY-friendly with plug-in operation (no additional controls required)
  • 7 watts per linear foot (constant wattage)
  • Safe: cUL Listed, CSA Listed, and cETLus Listed
  • Covered by a 2-year warranty

Specifications

Electrical

Amps 0.18 A
Cable Construction Twin conductor
Cable Type Constant Wattage
Conductor Insulation XLPE
Connection Method Plug-in
Ohms 685.7 Ω
Outer Insulation PVC
Plug-Type NEMA 5-15 (Type B)
Plug-in Cable Diameter 0.31″ / 8mm
Plug-in Cord Length 2′
Voltage 120 V
Watts 21 W
Watts Per Linear Ft. 7 W

Warranty / Certifications

Approvals cUL Listed, CSA Listed, and cETLus Listed
Warranty 2-year warranty

Product Dimensions

Cable Cross Section 0.31″ x 0.23″ / 8mm x 6mm
Heating Cable Length 3′
Splice Dimensions 0.56″ x 6.69″ x 0.94″ / 1.4cm x 17.5cm x 2.4cm
Weight 0.2 lbs

Installation

Maximum Pipe Diameter 1 ½″ (3.81cm)
Minimum Bend Radius 1″ (2.54cm)
Minimum Installation Temperature 15°F (-10°C)

Identifiers

SKU PTC120-7W-003
UPC (GTIN-12) 881308062330

Controls

Thermostat Built-in: ON setpoint 37.4°F (3°C), OFF setpoint 50°F (10°C)

Frequently Asked Questions

Showing all 5 questions

Simply put, yes--the right type of heat tape will really keep your pipes from freezing. By applying gentle heat, heat tape can prevent the water in your pipes from turning to ice and blocking the flow of water--or worse. Combined with proper insulation, heat tape regulates the overall temperature of your water pipes.

8 people found this helpful Was this helpful? Yes No

Heat tape is electrical equipment: improper installation, damaged cable, or misuse can cause fire or electric shock. Select cable approved for your pipe and location, follow its layout and insulation requirements, provide the specified electrical protection, and inspect it before each cold season. Do not use damaged equipment or overlap cable unless the exact product instructions permit it.

6 people found this helpful Was this helpful? Yes No

Yes, it can be used for both application types to prevent pipes from freezing and bursting during cold weather.

6 people found this helpful Was this helpful? Yes No

Heat trace, heat tape, or heating cable for pipes is typically an electric heating cable that can be attached to the pipe which helps keep non-flowing water pipes in poorly insulated perimeter walls flowing despite harsh winter temperatures.

4 people found this helpful Was this helpful? Yes No

Pipe heat tape is intended for freeze prevention, not as a guaranteed way to thaw an already frozen pipe. A frozen pipe may be damaged. Have the plumbing assessed and thawed safely by a qualified professional; never use an open flame. Before future cold weather, verify cable selection, thermostat placement, insulation, and electrical protection.

3 people found this helpful Was this helpful? Yes No

Customer Reviews