Ice Shield: DIY Roof and Gutter Deicing Kit (240’)


Ice Shield: DIY Roof and Gutter Deicing Kit (240’)




Support Page

Features

  • This 240' cable is recommended for use in large projects like a 36' gutter with 36" of roof overhang coverage and a 10' downspout

  • This kit includes the heating cable, roof clips, and cable spacers

  • DIY-friendly with simple plug-in operation (no additional controls required)

  • Delivers 5 watts per linear foot (constant wattage) for efficient removal of snow and ice

  • Safe: cUL Listed, CSA Listed, and cETLus Listed

Ice Shield: DIY Roof and Gutter Deicing Kit: Constant Wattage Description

One of the leading causes of roof and gutter damage is degradation caused by the formation of ice dams during winter. These harmful accumulations can wreak havoc on your roof or gutters, leading to leaks, loss of property value, and even costly replacements.

Save yourself the headache by installing a DIY-friendly Ice Shield: Roof and Gutter Deicing Kit from WarmlyYours. The 120 V constant-wattage (5 watts per linear foot) heating cables will prevent damage to your roof and gutters all winter long. These kits include everything you’ll need for an easy and safe installation.

Features:

  • Recommended for use in large projects like a 36' gutter with 36" of roof overhang coverage and a 10' downspout
  • Includes: heating cable, clips, and spacers
  • DIY-friendly with plug-in operation (no additional controls required)
  • 5 watts per linear foot (constant wattage)
  • Safe: cUL Listed, CSA Listed, and cETLus Listed
  • Covered by a 2-year warranty

Specifications

Electrical

Amps 10 A
Cable Construction Twin conductor
Cable Type Constant Wattage
Conductor Insulation XLPE
Connection Method Plug-in
Ohms 12 Ω
Outer Insulation PVC
Plug-Type NEMA 5-15 (Type B)
Plug-in Cord Length 6′
Voltage 120 V
Watts 1200 W
Watts Per Ft. 5 watts per linear ft.

Warranty / Certifications

Approvals cUL Listed, CSA Listed, and cETLus Listed
Warranty 2 Year Warranty

Product Dimensions

Cable Cross Section 1/4" x 3/16"
Cold Lead Length 6′
Heating Cable Length 240′
Weight 9 lbs

Logistics

Country of Origin (COO) China

Installation

Minimum Bend Radius 1″
Minimum Installation Temperature 15°F (-10°C)

Identifiers

SKU ETC120-5W-240-WY
UPC (GTIN-12) 881308071998

Customer Questions & Answers

Ice Shield: DIY Roof and Gutter Deicing Kit: Constant Wattage has 18 Questions and Answers.

Don't see the answer you're looking for? Post your question

Can the heating element be cut to length or shortened?

Our self-regulating heating product is designed to be cut to length at the jobsite by an installer where it can then be end-capped with accessories (sold separately).
However, our constant wattage kits contain heating elements that cannot be shortened or altered in any way.

9 people found this helpful.  Did you find this helpful? Yes No

Do radiant heating products have polarity?

Electric-resistance heating cables and systems have no polarity. This includes all current WarmlyYours heating elements.

9 people found this helpful.  Did you find this helpful? Yes No

Can the cable be left on in warm weather or all year long?

We do not recommend leaving the cable on all year long. It's an unnecessary use of energy to run the cable during warm weather and it could actually cause the heating cables to overheat if they're left on during very warm weather. 

6 people found this helpful.  Did you find this helpful? Yes No

How do I estimate the roof and gutter deicing cable length needed?

 Cable length needed depends on the sizes and areas of the roof that need to be deiced (roof with gutter, downspouts, valleys, and/or dormers). Our best recommendation is for you to give us a call (1-800-875-5285) and we can help you identify what measurements will need to be taken. Alternatively, you can
measure the dimensions of the aforementioned areas and refer to the installation manual to get an idea of how much cable you'll need. 

6 people found this helpful.  Did you find this helpful? Yes No

Can the cable be installed to remove already formed ice dams or to clear existing ice or snow from a roof?

It is not recommended to install this product to remove ice dams that have already formed or for the purpose of clearing the roof of existing ice and snow.

5 people found this helpful.  Did you find this helpful? Yes No

View all 18 Questions and Answers

Customer Reviews

Ice Shield: DIY Roof and Gutter Deicing Kit: Constant Wattage achieved an average rating of 5.0 stars with 4 reviews by our customers.

Have you used this product before? Leave a review

Quality Product

J S., Park City, UT on 01/10/2024

This is a quality product and far superior to the crap you can get at the local big box hardware store. It is packaged well, unravels nicely, and does not get tangled. My only complaint was certain lengths I needed were not in stock.

Quality in the details

J S., Park City, UT on 11/13/2023

WarmlyYours constant wattage heat tape is far better than the competition. Compared to the Frost King brand sold at Home Depot, and the Heat It brand sold on Amazon, WarmlyYours has a superior packaging. The heat tape always unravels without getting tangled, unlike the competitor brands. Also, the aluminum clips are nicely separated from one another, which makes it easy to grab what's needed.

Great customer experience

Helen C., Wood Dale, IL on 11/07/2023

The fact that they are willing to look at pictures and measurements to help figure out how much deicing cable that was needed was great in itself. Cable was high quality and there was plenty of roof connector clips and accessories.

Winter bomb cycle

Anonymous, Medina, OH on 12/27/2022

The recent winter bomb cycle was the first real test of the de-icing protection. It withstood the actual cold temperature, the added windchill factor and the high winds. It worked and stayed attached through it all.

View all customer reviews