UDG4-4999 Frequently Asked Questions

Don't see the answer you're looking for? Post your question

Frequently Asked Questions

Showing 10 of 19 questions

While WarmlyYours electric radiant floor heating systems are typically installed by your floor covering contractor, a licensed electrician is recommended for the final thermostat hook-up. With every quote, we provide an Installation Plan layout, together with an electrical plan that has all the info required for the electrician.

40 people found this helpful Was this helpful? Yes No

A floor heating system can work as a supplemental heating source and make the basement warmer. If more heat needs to be added to the room, you can experiment with setting the floor heating thermostat to higher temperatures.

6 people found this helpful Was this helpful? Yes No

The breaker and wire sizes are selected based on the total amperage of the WarmlyYours heating system connected to a single thermostat. This information is on the WarmlyYours heating system's installation plan, electrical plan, or UL label. Based on guidelines from the National Electrical Code: loads up to 16 Amps may utilize 12 gauge wire with a 20-Amp breaker, and loads up to 12 Amps - 14 gauge wire with a 15-Amp breaker. Local code and/or other factors may change these guidelines.

6 people found this helpful Was this helpful? Yes No

No, floor heating thermostats are not compatible with the towel warmers. We would also not recommend using both devices on the same control, as it does not take the same amount of time to reach the ideal temperature for each product, which could lead to one unit to overheat and the other to not function properly.

5 people found this helpful Was this helpful? Yes No

WarmlyYours's floor heating thermostats are typically universal and can be used with the majority of electric floor heating systems as a new or replacement controller. Please review the electrical specs of both the thermostat and the heating system to ensure a proper match for the heating system, sensor, etc. You can also give us a call at (1-800-875-5285) and we can help answer any remaining questions. 

2 people found this helpful Was this helpful? Yes No

The ground wire in the floor mat must be connected directly to the ground wire of the supply or to the house ground wire.

2 people found this helpful Was this helpful? Yes No

Cork flooring can be used with floor heating if the r-value is under 1. You will need to find the r-value of the flooring you choose and let your account manager know during the design stage. Cork flooring should have a low r-value to minimize trapped heat.

2 people found this helpful Was this helpful? Yes No

Yes, radiant floor heating can be a primary heat source if its heat output exceeds the room's heat loss. For best results, we recommend using a 15-watt system, covering at least 80% of the floor, and ensuring the space is well-insulated. Use our Heat Loss Calculator to verify your specific needs.

Was this helpful? Yes No

Yes, radiant floor heating is an excellent primary heat source for tiny houses in mild to moderate climates. Because tiny houses have small footprints, the 15-watt output of TempZone™ can easily maintain comfort while saving valuable wall space. Ensure the structure is well-insulated and use our Heat Loss Calculator to confirm.

Was this helpful? Yes No

We strongly recommend using one thermostat for each room/zone. This will help the system operate more efficiently while making it easier to customize the heating needs of each space. But it is possible to use one thermostat to control floor heating in two separate rooms along with power modules. All installations must comply with local Electrical Codes.

Was this helpful? Yes No

Yes, you can install multiple sensors while installing the floor heating system. Only one of these sensors should be connected to the floor heating thermostat. Any secondary sensors can be run through conduit up to the thermostat area to be connected in the future should anything happen to the original sensor. The sensor is low voltage and may not need conduit. If conduit is required, it will need to be separate from the return power leads.

Was this helpful? Yes No

Yes, we strongly recommend installing insulation like ThermalSheet™ over concrete slabs. Concrete acts as a "heat sink," absorbing warmth that should go to your floor. Insulation directs the heat upward, significantly improving efficiency, reducing warm-up times, and allowing the system to function effectively as a primary heat source.

Was this helpful? Yes No

Underlayment is recommended for floating floors (laminate, LVP, wood) and installations over cold subfloors like concrete. It provides thermal insulation to prevent heat loss and improves system efficiency. For tile and stone, the system is typically embedded in thinset, so a separate underlayment is often unnecessary.

Was this helpful? Yes No

A Warmly Yours indoor floor heating system should not be installed with a GFCI breaker because GFCI protection is built into the thermostat and power module.  And while it's not always required, we strongly recommend a dedicated circuit for each thermostat and power module to limit the occurrence of ground fault nuisance tripping caused by multiple GFCI devices on a circuit. The amperage of a breaker would depend on the amp draw of the heating system. For example, a TempZone Flex Roll (which provides approximately 15 watts of energy output per square foot) that is providing 15 square feet of heating coverage will draw only 225 watts ( 1.9 Amps), so a 15 Amp circuit would suffice.  Always size breakers according to your local Electrical Code requirements. 

Was this helpful? Yes No

WarmlyYours TempZone™ Flex Rolls and Easy Mats deliver 15 watts per square foot, the maximum allowed by the National Electrical Code. This provides 25% more heating power than the 12-watt industry standard. TempZone™ Cable can be spaced to deliver between 8 and 15 watts per square foot depending on your needs.

Was this helpful? Yes No

An area where large furniture will cover the floor should have enough clearance underneath to allow air to circulate. Any areas where floor heat may be trapped (rugs, box bottom furniture), let your sales rep know so we can design an installation plan around these areas.

Was this helpful? Yes No

Yes, electric radiant floor heating is ideal for basements because it warms the cold concrete slab and provides consistent heat from the ground up. In well-insulated finished basements, it can serve as the primary heat source, turning a typically chilly space into a comfortable, year-round living area.

Was this helpful? Yes No

Radiant floor heating can heat a sunroom if the space has high-quality insulation and double-pane glass. Since sunrooms have high heat loss, a 15-watt system is essential. In extremely cold climates or poorly insulated sunrooms, it is best used as a supplemental source to keep the floor comfortable.

Was this helpful? Yes No

Most systems provide only 12 watts per square foot, which often lacks the power for primary heating in cold climates. WarmlyYours TempZone™ delivers 15 watts—a 25% increase. This higher output allows the system to overcome heat loss more effectively, providing reliable primary warmth even when outdoor temperatures drop.

Was this helpful? Yes No