Relay Contactor (RC-40AMP)
This support page provides publications, manuals, specifications, videos, support articles, and common support questions
Support Questions
Showing all 5 questions
A GFCI/GFEP (Ground Fault Circuit Interrupter / Ground Fault Equipment Protection) works differently than a circuit breaker by specifically detecting a small imbalance in electrical current between the hot and neutral wires, which indicates a potential ground fault (like a person touching a live wire), and instantly shutting off the power to prevent shock, while a circuit breaker only trips when there's a significant overload in current flow on the circuit, like a short circuit or too many appliances plugged in.
Relays can fail due to excessive current or voltage. When a relay is exposed to too much current, the contacts can burn out. High voltage can also damage the coil. Other reasons include mechanical wear and tear, dust or dirt buildup, and moisture. These factors can cause the relay to malfunction or stop working entirely. Regular maintenance and using the relay within its specified limits can help prevent failures.
Yes, but the tear-out is the real risk. Scan the floor with thermal imaging before demo to map the existing hydronic tubing, and never fasten or drill into it. Keep the two systems on fully independent controls so they cannot fight each other, and do not place the electric floor sensor directly above a hydronic loop — the false-high reading will short-cycle the electric system. Call PRO technical support at 800-875-5285 to review the assembly before ordering.
GFCI can fail for various reasons, such as wear and tear, moisture, corrosion, power surges, faulty wiring, or improper installation. Some of these causes can be prevented by regular inspection and maintenance, while others may require professional assistance. It is important to note that GFCI devices (ex. thermostat, breakers, outlets) should be tested regularly as these do wear out over time.
Documents
Technical Information
Wiring Diagrams
Specifications
Electrical
| Connection | 2 single pole relays , 2 wires, line 1 & line 2 |
| Connection Method | Hardwired |
| Maximum Current | 40 A |
| Maximum Load (Resistive Only) | 120/240 V, 40 A |
| Voltage | 120 V |
Product Dimensions
| Length | 6″ |
| Weight | 7.3 lbs |
| Width | 6″ |
Identifiers
| SKU | RC-40AMP |
| UPC (GTIN-12) | 881308020392 |
Videos
Articles
- Companies that allow EFH under LVT
- Different types of wood and Electric Floor Heating
- EMF, Floor Heat and Pacemakers
- ETI Floor Heating Control FWT-3 Thermostat
- FLOR Carpet Squares and EFH
- Heating LVT, Vinyl, and VCT
- How to Extend Leads For Floor Heating Products
- How To Prevent Wood Floor Gaps
- OJ GFI When Switching a Relay Panel