Relay Contactor (RC-40AMP)

Relay Contactor (RC-40AMP)

Part Number: RC-40AMPPast Model
This support page provides publications, manuals, specifications, videos, support articles, and common support questions

Support Questions

Showing all 5 questions

A GFCI/GFEP (Ground Fault Circuit Interrupter / Ground Fault Equipment Protection) works differently than a circuit breaker by specifically detecting a small imbalance in electrical current between the hot and neutral wires, which indicates a potential ground fault (like a person touching a live wire), and instantly shutting off the power to prevent shock, while a circuit breaker only trips when there's a significant overload in current flow on the circuit, like a short circuit or too many appliances plugged in.

3 people found this helpful Was this helpful? Yes No

Relays can fail due to excessive current or voltage. When a relay is exposed to too much current, the contacts can burn out. High voltage can also damage the coil. Other reasons include mechanical wear and tear, dust or dirt buildup, and moisture. These factors can cause the relay to malfunction or stop working entirely. Regular maintenance and using the relay within its specified limits can help prevent failures.

2 people found this helpful Was this helpful? Yes No

Yes, but the tear-out is the real risk. Scan the floor with thermal imaging before demo to map the existing hydronic tubing, and never fasten or drill into it. Keep the two systems on fully independent controls so they cannot fight each other, and do not place the electric floor sensor directly above a hydronic loop — the false-high reading will short-cycle the electric system. Call PRO technical support at 800-875-5285 to review the assembly before ordering.

Was this helpful? Yes No

No, the RC-40AMP is controlled by a line voltage (120V/240V) thermostat.

Was this helpful? Yes No

GFCI can fail for various reasons, such as wear and tear, moisture, corrosion, power surges, faulty wiring, or improper installation. Some of these causes can be prevented by regular inspection and maintenance, while others may require professional assistance. It is important to note that GFCI devices (ex. thermostat, breakers, outlets) should be tested regularly as these do wear out over time.

Was this helpful? Yes No


Specifications

Electrical

Connection 2 single pole relays , 2 wires, line 1 & line 2
Connection Method Hardwired
Maximum Current 40 A
Maximum Load (Resistive Only) 120/240 V, 40 A
Voltage 120 V

Product Dimensions

Length 6″
Weight 7.3 lbs
Width 6″

Identifiers

SKU RC-40AMP
UPC (GTIN-12) 881308020392

Warranty / Certifications

Warranty Limited 3-year warranty and lifetime technical support