Snow Melt Aerial Sensor




Support Page

Features

  • Detects falling or blowing snow at temperatures below 38°F (3.3 °C)

  • Provides a more robust sensor at less weight, lower visual profile and lower cost comparing to the previous generation

  • Sleeker profile provides a very aesthetically pleasing appearance

  • For the most versatile and effective snow detection, use with the SCP-120 Premium Snow Melt Control

  • This sensor is compatible with SC-MZ-TOUCH, SCA-DUAL, and SCP-120 snow melt controls

Snow Melting Sensors Description

The AIR-SS-2 Aerial-Mounted Snow Sensor provides versatile and cost-effective automatic snow detection for snow melting and roof and gutter deicing systems. Easy to install, the AIR-SS-2 Aerial-Mounted Snow Sensor is appropriate for use with the SC-MZ-TOUCH, SCP-120, and SCA-DUAL controls. It senses both ambient temperature and precipitation, detecting falling or blowing snow at temperatures below 38°F (3.3°C). The included 16-inch, 3-conductor, 18 AWG lead allows for flexibility of installation, allowing sensors to be located at a distance up to 500 feet away from the controller using 22-gauge wires and up to 1000 feet using 18 gauge wires.

Specifications

Electrical

Accepted Voltage Frequency 24 V
Activation Temperature 38 °F
Lead Length 16″
Sensitivity Temperature and precipitation

Product Dimensions

Depth 1¾″
Diameter 1.75″
Height 3¾″
Weight 0.2 lbs
Width 1¾″

Installation

Installation Area Aerial

Identifiers

SKU AIR-SS-2
UPC (GTIN-12) 881308065485

Warranty / Certifications

Warranty 2 years

Frequently Asked Questions

Showing all 2 questions

After installation the sensor can be tested by cooling the sensor base with either ice (do not immerse the sensor in ice water, it is not water proof) or freeze mist. Locate the internal temperature sensor by first locating the indexing tab (see page 5 of the manual) and apply the mist to the base of the sensor on the opposite side of the indexing tab.

Once the unit is cooled continue by placing a drop of water on the moisture grid. If testing in the winter and the temperature is below 38°F (3.3°C), then simply placing a drop of water or a small amount of snow on the moisture grid will start a heating cycle. To stop the cycles, simply turn off the power for 5 to 10 seconds and then turn it back on.

Was this helpful? Yes No

The AIR-SS-2 can be mounted at a distance up to 500 feet away from the controller using 22-gauge wires and up to 1000 feet using 18-gauge wires.

Was this helpful? Yes No