CeraZorb® Insulating Synthetic Cork Underlayment (4′ x 4′) - 25 Sheets / 400 sq.ft


Part Number: CZRG-SH5MM-48X48-P25
This support page provides publications, manuals, specifications, videos, support articles, and common support questions


question-mark
Common Support Questions (8)

publication
Publications and Manuals (3)

specifications
Specifications (12)

Videos (4)

Articles (3)

Related Items (1)

Similar Items (9)

Create a new Support Request

Common Support Questions


While WarmlyYours electric radiant floor heating systems are typically installed by your floor covering contractor, a licensed electrician is recommended for the final thermostat hook-up. With every quote, we provide an Installation Plan layout, together with an electrical plan that has all the info required for the electrician.

Need more help? View support options

Please keep in mind that you must check your electric floor heating system with a digital ohmmeter in conjunction with a Circuit Check™. Take an initial reading as soon as you take the product out of the box to verify that it is within -5% / +10% of the values stated on the product’s label. This will give you a basis of comparison for future readings. Take a second reading once you have positioned the system to match your custom installation plan. It is also advisable to take an additional reading in the middle of the tile installation, just to make sure that the Circuit Check™ is doing its job. Then, take a final reading when you are finished with the floor installation and are ready to hook up the thermostat.

The Circuit Check™ is a tool developed by WarmlyYours to give you peace of mind and ensure trouble-free installations. Simply hook up the cold leads to the tool while you position the system to match your custom installation plan.

The Circuit Check™ will continuously monitor the continuity of the circuit during the installation of your system and during the installation of your flooring. The Circuit Check™ beeps immediately when a short in the system is detected, alerting you to a potentially damaged cable in the area you are working, before you lay the tile over the electric floor heating system.
 The WarmlyYours technical support team is available 24/7 to provide assistance if the alarm sounds, or if you would have any questions during your installation.

Need more help? View support options

Yes. Unlike the heating cable for electric floor heating, the cold lead wires can be trimmed or lengthened with additional lead wire which can be purchased from WarmlyYours.

Need more help? View support options

When installing electric floor heating over a concrete slab, an insulating underlayment like CeraZorb is highly recommended to ensure efficient operation, faster heating times and warmer floor temperatures.

Need more help? View support options

Yes, in most cases, an electric floor heating system can be effective as a primary heat source. However, our TempZone™ and Environ™ systems are most commonly used as a secondary heat source, providing floor-to-ceiling radiant heat to any room in your home where you desire more warmth and comfort.

If you are considering electric floor heating for an addition to your home, such as a sunroom where you have no other source of heat, WarmlyYours offers an innovative online tool which calculates approximate heat loss. This tool can help you to determine if a WarmlyYours’ electric radiant floor heating system will provide your desired comfort temperature throughout the year. You can access the Heat Loss Calculator or you can call us at (800) 875-5285 and a Customer Service Representative will make the calculation for you.

Need more help? View support options

The temperature of your floor can range anywhere between 75°F to 95°F. The floor's actual temperature will depend on a number of factors including the amount of heat loss that the room experiences as well as the room’s configuration. For instance, the warmth contained in a two story entry way would likely be less than that of a smaller, more enclosed area such as a bathroom. In a bathroom that is located on the second floor of your home or over another floor in your home that is typically heated, the temperature of your heated floor should easily reach a comfortable temperature of 85 degrees Fahrenheit, if the electric floor heating system is installed correctly. For the heat loss calculation for your specific room, you can access the Heat Loss Calculator or you can call us at (800) 875-5285 and a Customer Service Representative will make the calculation for you.

Need more help? View support options

Electric floor heating works by having an electric heating cable installed underneath the flooring (embedded or floating, depending on the system and floor type), which is then wired to a special thermostat (either one specifically designed for electric radiant floor heating, like a WarmlyYours’ nSpiration Series control, or a third-party thermostat). When turned on, the heating cable emits heat upward through the flooring which is then radiated throughout the room, heating all solid surfaces. 

Need more help? View support options

No, CeraZorb underlayment floats over the subfloor, adjacent sheets are staggered and taped together to prevent any overlapping.

Need more help? View support options


Publications and Manuals



Specifications


Insulation Specification

Acoustic testing on 6" slab, no ceiling IIC 52 wood construction. FIIC 59 - 7.5" concrete slab. ΔIIC 20 - 6" concrete slab
Compressive Strength 34 psi @ 10% Deformation
Thermal Insulation 1.5 R-Value

Product Dimensions

Coverage 400 sqft
Depth 0.1969 in
Length 48 in
Weight 27.5 lbs
Width 48 in

Identifiers

SKU CZRG-SH5MM-48X48-P25
UPC (GTIN-12) 881308056308

Warranty / Certifications

TCNA Robinson test Light Commercial
Warranty 5 years