No, as long as it's properly installed. However, improper installation, use, and/or maintenance of electrical heating cable can cause fires, electric shock, and/ or frozen pipes.
Need more help? View support options
Heat trace, heat tape, or heating cable for pipes is typically an electric heating cable that can be attached to the pipe which helps keep non-flowing water pipes in poorly insulated perimeter walls flowing despite harsh winter temperatures.
Need more help? View support options
Unfortunately there's no set answer for this because it depends on many factors such as the diameter of the pipes, the installation density of the heating cables, the outdoor temperature, the installation of thermal insulation sleeves, etc.
There are too many variables to provide an accurate answer. Even though this product is designed to keep pipes from freezing, it is not designed to thaw pipes. If your pipe has frozen with the heat tape installed and energized, please check the placement of the built-in thermostat and verify that the insulation has been properly installed and waterproofed.
Need more help? View support options
Yes, it can be used for both application types to prevent pipes from freezing and bursting during cold weather.
Need more help? View support options
By attaching a heating cable to the exterior of a pipe, it will transfer the heat to the pipe to prevent frozen pipes. And with the use of pipe insulation the heat will be evenly spread and won't dissipate as quickly.
Need more help? View support options
The highest surface temperature of the heating cable for pipes can be between 70°F and 80°F.
Need more help? View support options
No, heating cable for pipes will use a relatively low amount of power—anywhere from 21W to 210W (depending on length).
Need more help? View support options
While the entire product is warrantied for 2 years, it is equipped with a built-in thermostat that has a service life of approximately 100,000 activations. The service life of the constant wattage heating cable itself is 20 years.
Need more help? View support options
No. Do not run constant wattage heating cable through walls, ceilings, or floors. The constant wattage cable must be installed 1/2“ away from combustible material.
Need more help? View support options
Only use on water pipes with a length greater than 3‘. Maximum pipe diameter of 1.5“. Never use a cable that is longer than the pipe. Never install constant wattage pipe heat on plastic/PVC/PEX piping unless it is filled with water at all times. Never install on pipes heated above 149°F/65°C such as steam lines.
Need more help? View support options
Never spiral heating cable on pipes. Apply the constant wattage cable straight along the bottom of horizontal pipe, or the "weather side" of verticle pipe. For pipes 1“-1.5“ in diameter, apply two separate cables on opposite sides of the pipe. Please refer to the installation manual for further information.
Need more help? View support options
Heating cable may remain on the pipe year round, but WarmlyYours recommends turning off or disconnecting the power when air temperatures remain above 50°F/10°C. Always inspect the heating cable and its power connection at the beginning of the heating season.
Need more help? View support options
Constant wattage cable cannot be used on plastic pipe unless it is filled with water at all times. Never spiral or wrap heating cable around pipes. Keep the heating cable straight along the pipe. In order to obtain even heat distribution, WarmlyYours recommends wrapping plastic pipe with aluminum foil before applying the heating cable. Never use more than ½“ of fiberglass or other non-flammable pipe insulation because this can cause the cable to overheat and cause a serious fire hazard or electrical shock.
Need more help? View support options
Use good quality electrical tape with a minimum 176°F/80°C temperature rating at 5.9“ (15cm) intervals. Never use metal binding to secure heating cable to pipe.
Need more help? View support options
As the names imply, constant wattage cable uses fixed wattage output per linear foot and does not automatically adjust in response to temperature changes. Self-regulating cable is manufactured with a resistance matrix placed between its 2 buss wires that varies the ohms resistance per linear foot to automatically adjust in response to temperature changes. Learn more about this in our blog Self-Regulating vs. Constant Wattage Heating Cables.
Need more help? View support options
Ice Shield is 120V and outputs 5W/ft, and is designed for roof and gutter deicing applications.
PRO-Tect is 120V and outputs 7W/ft, and is designed for pipe freeze protection applications.
Need more help? View support options
Amps | 0.88 A |
Cable Construction | Twin conductor |
Cable Type | Constant Wattage |
Conductor Insulation | XLPE |
Connection Method | Plug-in |
Ohms | 137.1 Ω |
Outer Insulation | PVC |
Plug-Type | NEMA 5-15 (Type B) |
Plug-in Cable Diameter | 0.31″ / 8mm |
Plug-in Cord Length | 2′ |
Voltage | 120 V |
Watts | 105 W |
Watts Per Linear Ft. | 7 W |
Approvals | cUL Listed, CSA Listed, and cETLus Listed |
Warranty | 2-year warranty |
Cable Cross Section | 0.31″ x 0.23″ / 8mm x 6mm |
Heating Cable Length | 15′ |
Splice Dimensions | 0.56″ x 6.69″ x 0.94″ / 1.4cm x 17.5cm x 2.4cm |
Country of Origin (COO) | China |
Maximum Pipe Diameter | 1 ½″ (3.81cm) |
Minimum Bend Radius | 1″ (2.54cm) |
Minimum Installation Temperature | 15°F (-10°C) |
SKU | PTC120-7W-015 |
UPC (GTIN-12) | 881308072063 |
Thermostat | Built-in: ON setpoint 37.4°F (3°C), OFF setpoint 50°F (10°C) |
Do you need support or specifications for a specific model? Identify your model below.