Thermostat SmartStat™ Ambient Sensor 120V Non GFCI TH115-A-120S


Part Number: TH115-A-120S
This support page provides publications, manuals, specifications, videos, support articles, and common support questions


question-mark
Common Support Questions (8)

publication
Publications and Manuals (2)

specifications
Specifications (15)

Videos (3)

Articles (7)

Related Items (2)

Similar Items (2)

Create a new Support Request

Common Support Questions


Radiant heat travels through air, and typically heats up objects closer to the panel first and then the rest of the room later. Infrared heating from the panel can be easily detected from about 3-4 feet. Ideally, the radiant panel should be aimed onto the area with more use, since that will be the surface that will warm up first.

Need more help? View support options

If you have a room with "average" insulation levels, take the square footage and multiply it by 7 or 8 watts per square foot. That will provide a good estimate of the watts needed to heat that space.

Need more help? View support options

We do not have a Radiant Panels Running Cost Calculator.  However, this can be determined easily by taking the panel’s wattage, dividing it by 1000, and then multiplying the result by the local kW/hr cost – then take this hourly cost and multiple by 730 hours to get a monthly estimate.

Need more help? View support options

The startup heating time for this infrared heating system is approximately 5 to 10 minutes. However, your room will not feel warmer immediately because the cold objects in the room (furniture, walls, ceilings, floors, etc.) need to warm up first. Once these surfaces are heated via infrared heating, the warmth will spread throughout the room.

Need more help? View support options

We recommend an open 1.5" (3.5cm) space around the edge of the LAVA radiant panel for air circulation and easier installation. UL requires that the On/Off switch must be operable and visible, and no flammable materials may be used around the LAVA radiant panel.

Need more help? View support options

Please abide by local electrical code guidelines. Lava radiant panels may not be installed in "wet locations" such as showers or saunas. The top, bottom, and sides must not be closer than 12 inches from any other object or surface in order to effectively radiate heat. The Lava radiant panels may not be placed behind doors. We do not recommend installing Lava radiant panels on ceilings.

Need more help? View support options


Publications and Manuals



Specifications


Electrical

Amps 1 amps
Connection 4 wires, double pole
Connection Method Hardwired
Ground Fault Protection (GFCI) Class A, 5 mA
Maximum Load (Resistive Only) 1800 W - 120 V, 15 A / 3600 W - 240 V, 15 A
Supply 120 VAC, 50/60Hz / 240 VAC, 50/60Hz
Voltage 120 VAC
Watts 1 watts

Logistics

Country of Origin (COO) China

Product Dimensions

Depth 2 in
Installed Depth 0.75 in
Length 4″
Width 3″

Identifiers

SKU TH115-A-120S
UPC (GTIN-12) 881308024710

Videos



Articles



Similar Items


Do you need support or specifications for a specific model? Identify your model below.



Speak to a radiant heating expert


Can’t find what you’re looking for? Create a Support Request