Support Questions
Showing all 6 questions
Within the Product Dimensions of the WarmlyYours web page for your particular Towel Warmer, it is listed as the general 'Mounting Footprint'. Measure all dimensions of the delivered product prior to rough-in and installation because continuous improvements in the product may affect the finished dimensions.
Test the ohms of the unit to verify that it is within 5-10% of the resistance indicated in specs. Verify that there is at least 110 volts present into and out of the power supply. If the ohms are too high, the warmer will feel cooler. The lower the voltage, the cooler the unit.If these values are within specs, the towel warmer is working as designed.
The dash represents the "on" position because it signifies a closed circuit, allowing power to flow. The O represents the "off" position, indicating an open circuit where power is disconnected. You can further identify the on/off state of the towel warmer by the LED coming on around the switch when powered.
If a warmer towel is desired, try folding the towel over or unfold it to experiment, try a thicker towel (traps more heat, resulting in higher surface temperatures), a different fabric (cotton vs. blends), leave the towel warmer on longer before the shower (thicker towel plus longer heating time), or place a second towel on the warmer to trap more heat. Keep in mind, the towel will at some point reach its maximum temperature on the towel rack. If that time is an hour, leaving the warmer on all day will not raise the maximum temperature of that towel or warmer, but if you would like to experiment, that's OK, too.
Documents
Technical Information
Sell Sheets
- Comparison Chart for Timers and Switches for Towel Warmers or Infrared Heating Panels (English)
- Elements Plug-in Towel Warmer Sell Sheet Canada (English)
Operation Manuals
- Elements Installation Manual (English)
- Elements Installation Manual (French)
- Wemo Plug In Guide (English)
Publications
Wiring Diagrams
Technical Specifications
Specifications
Electrical (TW-E4PCP)
| Amps | 0.5 A |
| Connection Method | Plug-in |
| Cord Length | 5′ |
| Ingress Protection (IPxx) Rating | IP44 |
| Ohms | 240 Ω |
| On/Off Switch | Yes |
| Plug-Type | NEMA 5-15 (Type B) |
| Thermal Power | 0.06 kW |
| Voltage | 120 V |
| Watts | 60 W |
Performance (TW-E4PCP)
| Average Surface Temperature | 131°F / 55°C |
| BTU Per Hour | 205 Btu |
| Heat-up Time | 15-20 minutes |
| TempSmart Safety Limit | N/A |
| Towel Capacity | 1-2 |
Appearance (TW-E4PCP)
Electrical (CO-SW-WFR-WM)
| Connection Method | Plug-in |
| Maximum Current | 15 A |
| Maximum Load (Resistive Only) | 15Amp |
| Voltage | 120 V |
Product Dimensions (TW-E4PCP)
| Depth | 3½″ |
| Height | 28½″ |
| Mounting Footprint | Recommended distance between adjustable brackets is 12″ (305mm) |
| Size Classification | Compact |
| Weight | 7 lbs |
| Width | 16.3″ |
Identifiers (CO-SW-WFR-WM)
| Ground Fault Protection (GFCI) | No |
| SKU | CO-SW-WFR-WM |
| UPC (GTIN-12) | 881308040536 |
Thermostat (CO-SW-WFR-WM)
| Has Floor Sensor | n |
Logistics (TW-E4PCP)
| Package Contents | Towel Warmer, installation manual and hardware kit |
Identifiers (TW-E4PCP)
| SKU | TW-E4PCP |
| Towel Warmer Collection Name | Classic Collection |
| UPC (GTIN-12) | 881308010980 |
Product Dimensions (CO-SW-WFR-WM)
| Weight | 0.6 lbs |