PT-END-KIT-H Frequently Asked Questions
Frequently Asked Questions
Showing 10 of 20 questions
Simply put, yes--the right type of heat tape will really keep your pipes from freezing. By applying gentle heat, heat tape can prevent the water in your pipes from turning to ice and blocking the flow of water--or worse. Combined with proper insulation, heat tape regulates the overall temperature of your water pipes.
Heat tape is electrical equipment: improper installation, damaged cable, or misuse can cause fire or electric shock. Select cable approved for your pipe and location, follow its layout and insulation requirements, provide the specified electrical protection, and inspect it before each cold season. Do not use damaged equipment or overlap cable unless the exact product instructions permit it.
Pipe heat tape is intended for freeze prevention, not as a guaranteed way to thaw an already frozen pipe. A frozen pipe may be damaged. Have the plumbing assessed and thawed safely by a qualified professional; never use an open flame. Before future cold weather, verify cable selection, thermostat placement, insulation, and electrical protection.
Self-regulating heating cables, like PRO-Tect: Pipe Freeze Protection cables, use a conductive polymer core, which continually adjusts its heat output.
This is why this type of cable, unlike some heat tapes, won’t burn out if it is wrapped closely together, overlapped, or over-insulated. This also means lower operating costs and increased energy efficiency.
No, the FPT 130 provides a summary alarm via a dry contact relay. This relay is energized whenever the unit is powered. So, with power off the NC contact is closed, and the NO contact is open. When the unit is powered these are in the opposite state. A fault will de-energize the alarm relay and close the NC contact. This allows for a default, power loss alarm without power.
Yes, insulation is highly recommended for use with a pipe freeze protection system for the following reasons:
· It helps cut down on heat loss from the heated water pipe.
· Properly installed insulation helps keep the cable in good contact with the water pipe so that maximum surface area contact is achieved.
· While the cable is wet location approved, weatherproofed insulation adds an extra layer of protection. Ideally, the insulation will be nonflammable and waterproofed.
At a minimum: a PRO-Tect Pipe Freeze Protection Self-Regulating Cable, an End Seal kit, and a Power Connection Kit. However, we also strongly recommend a control. All of these components are directly available from WarmlyYours (along with other accessories).
Use of another manufacturer’s components will void the warranty.
No. Only install pipe heat (heat trace cable) in accessible locations. Do not install this self regulating cable in walls or any place where the cable is hidden. Do not run it through walls, ceilings, or floors. The cable must be installed 10“ away from combustible surfaces, such as wood, and it should not be embedded in insulation or roofing material.