Waterproof Outdoor Thermostat Frequently Asked Questions

Don't see the answer you're looking for? Ask a question

Frequently Asked Questions

Showing 10 of 11 questions

At a minimum: a PRO-Tect Pipe Freeze Protection Self-Regulating Cable, an End Seal kit, and a Power Connection Kit. However, we also strongly recommend a control. All of these components are directly available from WarmlyYours (along with other accessories).

Use of another manufacturer’s components will void the warranty.

Was this helpful?

WarmlyYours offers four thermostat and controller options for PRO-Tect pipe freeze protection heating systems:

  • Air Sensing Thermostat (AIR-STAT) — A simple automatic thermostat with a capillary bulb sensor. Activates when air temperature drops to 40°F and shuts off when it warms back up. Lowest-cost automatic option. Rated for 22A at 240V. NEMA 4X outdoor enclosure.
  • Economy Pipe Thermostat (PT-ECONOMY) — Four fixed temperature setpoints (30°F, 38°F, 45°F, 50°F), built-in GFEP, LED status indicators, and a 20-foot sensor lead. Rated for 30A. Good for standard residential and light commercial installations.
  • Single-Zone Digital Thermostat (PT-SINGLE) — Fully adjustable setpoint (-99.9°F to 999°F) with a 2.7" display, adjustable GFEP (1–300mA), and a 100k ohm NTC sensor with 20-foot lead. Rated for 30A. Best for precise temperature control.
  • Dual-Zone Digital Thermostat (PT-DUAL) — Same digital control as the PT-SINGLE but manages two independent heating circuits from a single enclosure. Includes two sensors. Best for large installations or multi-zone pipe protection.

All controls include the sensor, feature NEMA 4X weatherproof enclosures, and are rated for non-hazardous locations. Contact our radiant experts for help selecting the right control for your project.

Was this helpful?

GFEP stands for Ground Fault Equipment Protection. It is a safety circuit that continuously monitors the current flowing through your heating cable. If a ground fault is detected (current leaking to ground, which can indicate damaged cable insulation), the GFEP trips the circuit and shuts the system off.

GFEP is important for pipe freeze protection systems because:

  • Heating cables are often installed in damp or wet environments (under pipes, in crawl spaces) where insulation damage is more likely.
  • A ground fault in a high-current heating circuit can cause fire, shock hazard, or cable failure.
  • GFEP trips before the fault escalates, protecting your property and your heating system.

The PT-ECONOMY includes a fixed 30mA GFEP. The PT-SINGLE and PT-DUAL have adjustable GFEP (1–300mA) so you can set a sensitivity level appropriate for your installation. The AIR-STAT does not include GFEP.

If your installation is in a wet or damp location, WarmlyYours recommends choosing a control with built-in GFEP for maximum protection.

Was this helpful?

The correct temperature setpoint depends on which control you have and where the sensor is installed:

Air Sensing Thermostat (AIR-STAT) — Fixed setpoint of 40°F. The system activates when air temperature drops to this level and shuts off when it warms up. No adjustment needed.

Economy Thermostat (PT-ECONOMY) — Four preset options: 30°F, 38°F, 45°F, or 50°F. For most pipe freeze protection applications, 38°F or 40°F is a good starting point—it activates the cable before pipes reach freezing temperatures.

Digital Thermostats (PT-SINGLE / PT-DUAL) — Fully adjustable. A common recommendation is to set the activation point between 35°F and 40°F if measuring air temperature near the pipes, or slightly higher (45°F–50°F) if the sensor is measuring pipe surface temperature directly.

For specific guidance on setpoint and sensor placement for your installation, contact our radiant experts—we can help you set up the system correctly for your climate and pipe location.

Was this helpful?

You need the PT-DUAL dual-zone thermostat when your pipe freeze protection installation has two independent heating circuits that you want to control from a single enclosure.

Common scenarios that require dual-zone control:

  • Two separate pipe runs in different areas (e.g. crawl space and exposed exterior plumbing)
  • A large installation that was split across two circuits to stay within the 30A per-circuit load limit
  • Two different pipe materials or exposure levels that benefit from independent temperature setpoints

The PT-DUAL includes two sensors and two independent sets of controls in one NEMA 4X enclosure. Each zone can have its own temperature setpoint and operates independently.

If you only have one heating circuit, the PT-SINGLE is sufficient. If you are unsure how many circuits your installation requires, our free system design service will tell you exactly what you need.

Was this helpful?

Turn on heat tape when temperatures drop to 20°F (-6°C) or below and are expected to stay there for 6+ hours. For optimal protection, use automatic controls that activate cables based on temperature conditions.Manual operation:

  • Turn on: When temps forecast to reach 20°F or below for extended periods
  • Turn off: When temps rise above 40°F and stay there for 24+ hours
  • Monitor: Check daily during cold snaps

Automatic operation (recommended):

  • Thermostat control: Activates at preset temperature (typically 32–40°F)
  • Smart control: Remote monitoring and weather-based activation
  • Timer control: Set schedule for coldest overnight hours

Optimal operating temperatures:

  • Below 20°F: Peak freezing risk (heat tape should run continuously)
  • 20–32°F: Moderate risk (run heat tape, especially overnight)
  • Above 32°F: Lower risk, but vulnerable pipes may still need protection

Operating tips:

  • Start early: Turn on heat tape before temperatures drop for best results
  • Run overnight: Pipes freeze most often during coldest overnight hours
  • Extend runtime: Keep heat tape on until temps stay above 40°F for 24+ hours
  • Don't turn off too early: Pipes can freeze during brief cold snaps

When to activate by region:

  • Northern climates: October–April (extended winter season)
  • Moderate climates: November–March (core winter months)
  • Southern climates: December–February (occasional freezes)

Energy-saving tip: Smart controls can reduce operating costs by 30–50% by running cables only when needed. They monitor weather forecasts and activate automatically. Shop control options.

Emergency activation: If you forgot to turn on heat tape and temps drop suddenly, activate immediately and let water drip from faucets until pipes warm up.

Was this helpful?

Yes. The SCW-120-15A WiFi switch includes built-in WiFi and connects to the WarmlyYours SmartControl app. From your smartphone you can turn the deicing system on or off remotely, create manual schedules, and monitor system status from anywhere with an internet connection.

For automatic operation combined with remote monitoring, you can pair an automatic control (SCP-120, SCE-120, or SCA-DUAL) with the aerial sensor—the system runs itself based on real weather conditions while you can still check in remotely using the SCW-120-15A if needed for manual override.

The other controls (SCP-120, SCE-120, SCA-DUAL, SCM-DUAL, AIR-STAT) are standard hardwired controls without built-in WiFi connectivity.

Was this helpful?

Each WarmlyYours roof deicing control has a maximum rated load:

  • SCV-DUAL — 16A (built-in sensor, outdoor-rated enclosure)
  • SCP-120 — 24A at 120V
  • SCA-DUAL — 30A at 240V
  • SCE-120 — 3 × 16A (three-zone control)
  • SCM-DUAL — 20A at 120V; 10A at 240V or 277V
  • SCW-120-15A — 15A at 120V only (larger loads or other voltages need a relay panel)
  • AIR-STAT — 22A resistive (rated at 125, 250 and 480 VAC); one circuit per control

If your roof deicing installation exceeds the capacity of a single control—common for large commercial rooflines, multiple gutters, or multi-zone systems—you will need a relay panel. A relay panel uses the low-current signal from your control to switch heavy-duty contactors, allowing a single control to manage a system far larger than it could handle directly.

Our free system design service will confirm whether a relay panel is required for your installation and which model is correct.

Was this helpful?

The Aerial Sensor (AIR-SS-2) is a standalone sensor that mounts above the heated area—typically on a fascia board, eave, or exterior wall post. It continuously monitors two conditions:

  • Air temperature — Checks whether outdoor temperature is below freezing (or close to it).
  • Precipitation — Detects the presence of snow, rain, or ice above the sensor.

When both conditions are met (cold enough + moisture present), the sensor signals the automatic control to activate the roof deicing system. When conditions improve—the temperature rises or precipitation stops—the system shuts off.

The aerial sensor is compatible with the following automatic controls: SCP-120, SCE-120, and SCA-DUAL. It mounts externally and does not require embedding in the roof structure, making it suitable for both new and retrofit installations.

Was this helpful?

Automatic controls use an aerial sensor to monitor outdoor conditions and activate your roof deicing system only when temperatures are cold enough and moisture is present. The system turns on when it is needed and shuts off automatically—you never have to think about it. This is the recommended approach for most installations because it prevents ice dams before they form and avoids running the system unnecessarily.

Manual controls give you direct on/off control of the system:

  • The SCM-DUAL contactor switch includes a 24-hour programmable timer so you can schedule fixed operating windows during known storm hours.
  • The SCW-120-15A WiFi switch lets you turn the system on or off remotely from a smartphone app, and also supports manual scheduling.

Automatic controls are strongly recommended for roofs and gutters in climates with frequent freeze-thaw cycles or unpredictable weather. Manual controls are a lower-cost option for small installations or properties where someone can monitor conditions closely.

Was this helpful?

Turn on roof heating cables before snow falls when temperatures drop to 32°F (0°C) or below and freezing precipitation is forecast.

For optimal protection, automatic controls are recommended to activate cables only when both freezing temperatures and moisture are detected.

  • Automatic operation: Aerial or gutter sensors detect moisture and cold temperatures, turning the system on before snow accumulates and off when dry.
  • Manual operation: Turn cables on when freezing precipitation is expected, and turn them off once snow and ice have melted and drained.
  • Critical range: Maintain operation between 10°F and 34°F, the peak range for ice dam formation.
  • Post-storm drainage: Keep cables on for 2 to 4 hours after precipitation stops to ensure meltwater drains fully.

Using automatic controls prevents unneeded run time compared to continuous manual operation. Shop roof and gutter controls.