TempZone™ Floor Heating Ruler Cable 120V, (3.7W/ft.), 375 ft., 11.6A

5.00
Based on 4 reviews



How Much Cable Will I Need?
Coverage (sq. ft.) Based on Cable Spacing
Length Voltage 3" 3.5" 3.75" 4" 5"
30′ 120 7.5 8.8 9.4 10 12.5
40′ 120 10 11.7 12.5 13.3 16.7
50′ 120 12.5 14.6 15.6 16.7 20.8
55′ 240 13.8 16 17.2 18.3 22.9
65′ 240 16.3 19 20.3 21.7 27.1
70′ 120 17.5 20.4 21.9 23.3 29.2
75′ 240 18.8 21.9 23.4 25 31.3
90′ 120 22.5 26.3 28.1 30 37.5
95′ 240 23.8 27.7 29.7 31.7 39.6
115′ 240 28.8 33.5 35.9 38.3 47.9
120′ 120 30 35 37.5 40 50
150′ 120 37.5 43.8 46.9 50 62.5
155′ 240 38.8 45.2 48.4 51.7 64.6
180′ 120 45 52.5 56.3 60 75
195′ 240 48.8 56.9 60.9 65 81.3
220′ 120 55 64.2 68.8 73.3 91.7
235′ 240 58.8 68.5 73.4 78.3 97.9
260′ 120 65 75.8 81.3 86.7 108.3
275′ 240 68.8 80.2 85.9 91.7 114.6
300′ 120 75 87.5 93.8 100 125
315′ 240 78.8 91.9 98.4 105 131.3
340′ 120 85 99.2 106.3 113.3 141.7
355′ 240 88.8 103.5 110.9 118.3 147.9
375′ 120 93.8 109.4 117.2 125 156.3
395′ 240 98.8 115.2 123.4 131.7 164.6
432′ 120 108 126 135 144 180
435′ 240 108.8 126.9 135.9 145 181.3
515′ 240 128.8 150.2 160.9 171.7 214.6
595′ 240 148.8 173.5 185.9 198.3 247.9
675′ 240 168.8 196.9 210.9 225 281.3
749′ 240 187.3 218.5 234.1 249.7 312.1
864′ 240 216 252 270 288 360

The amount of cable you'll need depends on the heat output and amount of heating coverage you want, both of which are impacted by the spacing of the heating cable. The spacing of the heating elements is dictated by how the cable is installed and WarmlyYours offers two different installation methods: with Fixing Strips or with our Prodeso Membrane.

Fixing Strips

An economical option, requires more work than the membrane.


Ideal spacing for installing TempZone 3.7-watt Cable:

  • 3" (14.8-watts per sq. ft.)

Other spacing options:

  • 4" (11.1-watts per sq. ft.)
  • 5" (8.88-watts per sq. ft.)
Prodeso Membrane

Costlier than strips, speeds up installation and provides uncoupling benefits


Ideal spacing for installing TempZone 3.7-watt Cable:

  • 3.75" (11.84-watts per sq. ft.)

Other spacing options:

  • 5" (8.88-watts per sq. ft.)

You can use our quote tool to get a rough estimate of the amount of cable you'll need for a project.

Get Started


Or contact us for help:

You can also submit a drawing of your project (with dimensions) and we'll provide you with a free installation plan with the exact amount of cable you'll need. Get started

Support Page

Features

  • This 120V cable is 375 ft. long

  • Comes with easy-to-read hash marks at every half-inch, inch, and foot increment on the cable

  • Can be used to heat some of the most popular floor coverings like tile, stone, marble, luxury vinyl tile, and more

  • Provides 3.7 watts of heat output per linear foot which translates to 9-15 watts per sq. ft. (depending on spacing)

  • Covered by our industry leading 25-year No Nonsense™ Warranty

Description

The TempZone Floor Heating Ruler Cable is the first electric radiant heating cable to feature easy-to-read hash marks at every half-inch, inch, and foot increment. This innovative design, along with a free SmartPlan installation plan from WarmlyYours, ensures the installer is using the proper amount of cable while they’re laying it out along with making sure the heating elements are in the proper location. This will help guarantee a smooth installation of the floor heating system and even heating coverage for the end user.

The TempZone Floor Heating Ruler Cable is meant to be embedded in thinset or self-leveling compound beneath a wide range of floor coverings like tile, marble, stone, LVT, and more. The cable provides 3.7 watts per linear foot (9-15 watts per sq. ft. depending on spacing).

This cable is also very safe with a UL listing for use in both the US and Canada and ultra-low EMF levels due to a 100% Mylar shield around the ground wire in the cable. The TempZone Floor Heating Ruler Cable is also more durable than many other comparable cables due to its crush resistant ETFE (fluoropolymer) core insulation and high-temperature PVC jacket. Additionally, the elements of the cable are constructed in such a way that the cable has exceptional flexibility in nearly all directions.

The TempZone Floor Heating Ruler Cable can be installed in two different ways: with fixing strips or with an uncoupling membrane. The fixing strips are complimentary and are the most economical but also labor intensive option for installation. Using an uncoupling membrane is more costly but also provides other benefits like speed of installation, crack isolation, and the possibility of waterproofing the installation with accessories.

The TempZone Floor Heating Ruler Cable is covered by our industry-leading 25-year No Nonsense™ Warranty.

Features:

  • This is a 375 ft. long 120V cable
  • High-visibility hash marks at every half-inch, inch, and foot increments
  • 3.7 watts per linear foot of heat output (9-15 watts per sq. ft. depending on spacing)
  • Can be used to heat a range of floor coverings like tile, stone, marble, LVT, and more
  • More durable and flexible than most most comparable electric floor heating cables
  • Safe: cULus listed
  • Warranty: 25-year No Nonsense™ Warranty

Specifications

Electrical

Amps 11.57 A
Cold Lead Wire Gauge 16 AWG
Floor Load 1.39 kW
Ohms 10.37 Ω
Ohms Per Ft 0.028 Ohm/ft
Thermal Power 1.39 kW
Voltage 120 V
Watts 1389 W
Watts Per Sq. Ft at 3.75 Inch Spacing Up to 12
Watts Per Sq. Ft. 9-15
Watts Per Sq. Ft. at 3 Inch Spacing Up to 15
Watts Per Sq. Ft. at 4 Inch Spacing Up to 11
Watts Per Sq. Ft. at 5 Inch Spacing Up to 9

Warranty / Certifications

Approvals cULus
Warranty 25 Year Warranty
Wet Location Listed US, Canada

Performance

BTU Per Hour 4739 Btu

Product Dimensions

Cold Lead Length 12′
Cold Lead Thickness 0.22″
Coverage at 3 Inch Spacing 93.8 ft²
Coverage at 3.5 Inch Spacing 109.4 ft²
Coverage at 3.75 Inch Spacing 117.2 ft²
Coverage at 4 Inch Spacing 125 ft²
Coverage at 5 Inch Spacing 156.3 ft²
Factory Splice Thickness 0.41″
Heating Element Thickness 3/16″
Length 375′
Weight 11.4 lbs

Appearance

Color Yellow

Installation

Fixing Strips at 3 inch spacing 80
Fixing Strips at 4 inch spacing 100
Fixing Strips at 5 inch spacing 130
Floor Types Tile, Marble, Stone, Vinyl, LVT, LVP, Wood, Bamboo, Carpet, and more
Ideal Cable Spacing with Fixing Strips 4″
Ideal Cable Spacing with Prodeso Membrane 3.75″

Logistics

Package Contents (1) TempZone Floor Heating Ruler Cable 120V 3.7W/ft 375 ft 11.6A (RCT-120-0375); 1x Floor Heating Sensor (FH-BACKUP-SENSOR)
UNSPSC Code 40101830

Identifiers

SKU RCT-120-0375
UPC (GTIN-12) 881308076276

Installation Plans

Loading Installation Plans...

Loading installation plans...

Documents

Loading Documents...

Loading documents...

Frequently Asked Questions

Loading Frequently Asked Questions...

Loading frequently asked questions...

Customer Reviews

Loading Customer Reviews...

Loading customer reviews...