SC-MZ-TOUCH Frequently Asked Questions

Don't see the answer you're looking for? Post your question

Frequently Asked Questions

Showing 10 of 18 questions

The AIR-SS-2 can be mounted at a distance up to 500 feet away from the controller using 22-gauge wires and up to 1000 feet using 18-gauge wires.

Was this helpful? Yes No

Each zone may be activated for any length of time. No two applications are the same. You can start with 10 minutes and adjust up to 59 minutes per zone, and through trial and error, find the optimum zone durations for the best operation of your system.

5 people found this helpful Was this helpful? Yes No

Pavement Snow and Ice Sensor Kit (SIT–6E Sensor + Housing) and Snow Melt Aerial Sensor (AIR-SS-2).

3 people found this helpful Was this helpful? Yes No

The system may be shut off by pressing the OFF/CONFIG tab on the screen.

2 people found this helpful Was this helpful? Yes No

Yes. When more than one sensor is used, any positive activation by either of the sensors will activate the controller.

For example, the AIR-SS-2 aerial sensor and the SC-SS-PAV-6E-KIT slab sensor can be connected simultaneously for increased reliability.

2 people found this helpful Was this helpful? Yes No

If the “SNOW SENSOR OVERRIDE” button is pressed, the system will run for the set amount of time which was programmed in to the user defined “AFTER RUN” field.  To cancel the “SNOW SENSOR OVERRIDE” you must turn the system “OFF”.

Page 4 of https://www.warmlyyours.com/en-US/publications/ZONEBRAKER-TOUCHSCREEN-MULTI-ZONE-SNOW-MELTING-CONTROLLER-MANUAL-A.pdf

2 people found this helpful Was this helpful? Yes No

This control is capable of controlling up to 4 separate zones.

2 people found this helpful Was this helpful? Yes No

No, you may vary the times for each zone as necessary.

2 people found this helpful Was this helpful? Yes No

The "Max Slab Temp" sensor value should be set to 50 degrees F, and adjusted as necessary to optimize operation.

1 person found this helpful Was this helpful? Yes No

This control does not incorporate a built in GFEP protection. GFEP protection must be supplied by GFEP breakers.

1 person found this helpful Was this helpful? Yes No

No, the RCO can only be used with the SCA-DUAL or the SCP-120 snow-melting controllers.

1 person found this helpful Was this helpful? Yes No

No. multiple sensors can be used, but when they activate, the entire installation activates and the control will start controlling the entire installation (all zones attached to the control).

1 person found this helpful Was this helpful? Yes No

Ensure that all the zones have a time value set for run-time operation. If a time value is not set for a particular zone, it will not activate.

1 person found this helpful Was this helpful? Yes No

GFEP is the National Electric Code (NEC) required protection for fixed outdoor deicing and snow-melting equipment, which may be accomplished by using circuit breakers equipped with ground-fault equipment protection (GFEP) of 30 mA. It is important to understand that this required equipment protection is NOT the same as a 5 mA GFCI used for personal protection.

11 people found this helpful Was this helpful? Yes No

When the design requirement's amp draw exceeds the selected controller's capacity.

5 people found this helpful Was this helpful? Yes No

It depends on how the system is intended to operate. If the expectation is manual operation (ex. WiFi or Timer Control), then no sensors are required. If the expectation is automatic operation, then the system will require at least one snow sensor.

2 people found this helpful Was this helpful? Yes No

Ground fault equipment protection (GFEP) is intended to provide protection for equipment against damaging line-to-ground currents by disconnecting all ungrounded conductors of the faulted circuit.

2 people found this helpful Was this helpful? Yes No

No, a sensor is not required with the snow melt system. However, certain automatic controllers require a temperature/moisture sensor to sense atmospheric conditions and may also require an in-slab, high temperature limit sensor to be installed (notably, asphalt installations).

1 person found this helpful Was this helpful? Yes No