nJoin 2.0 Power Module with Class A GFCI


nJoin 2.0 Power Module with Class A GFCI
Part Number: USG5-4000
This support page provides publications, manuals, specifications, videos, and common support questions

Common Support Questions (6)
Publications and Manuals (5)
Specifications (18)
Videos (1)
Create a new Support Request
Shop Now

Common Support Questions


The breaker and wire sizes are selected based on the total amperage of the WarmlyYours heating system connected to a single thermostat. This information is on the WarmlyYours heating system's installation plan, electrical plan, or UL label. Based on guidelines from the National Electrical Code: loads up to 16 Amps may utilize 12 gauge wire with a 20-Amp breaker, and loads up to 12 Amps - 14 gauge wire with a 15-Amp breaker. Local code and/or other factors may change these guidelines.

6 people found this helpful.  Did you find this helpful? Yes No

In theory, it is possible, if no other options are available. We do not recommend it, but If the thermostat is controlling the floor temperature with a floor sensor, then it can go on an exterior wall. It is important that the floor sensor gets located in an area of the floor not hit by sunshine.

If the thermostat will be controlling the air temperature with the built-in ambient sensor, then it should go on an interior wall.

3 people found this helpful.  Did you find this helpful? Yes No

A GFCI/GFEP (Ground Fault Circuit Interrupter / Ground Fault Equipment Protection) works differently than a circuit breaker by specifically detecting a small imbalance in electrical current between the hot and neutral wires, which indicates a potential ground fault (like a person touching a live wire), and instantly shutting off the power to prevent shock, while a circuit breaker only trips when there's a significant overload in current flow on the circuit, like a short circuit or too many appliances plugged in.

1 person found this helpful.  Did you find this helpful? Yes No

Relays can fail due to excessive current or voltage. When a relay is exposed to too much current, the contacts can burn out. High voltage can also damage the coil. Other reasons include mechanical wear and tear, dust or dirt buildup, and moisture. These factors can cause the relay to malfunction or stop working entirely. Regular maintenance and using the relay within its specified limits can help prevent failures.

1 person found this helpful.  Did you find this helpful? Yes No

No, a circuit breaker will NOT protect against a power surge; a circuit breakers primary function is to protect against excessive current flow (overload), while a surge protector is specifically designed to handle voltage spikes, which are what power surges are considered to be.

1 person found this helpful.  Did you find this helpful? Yes No

GFCI can fail for various reasons, such as wear and tear, moisture, corrosion, power surges, faulty wiring, or improper installation. Some of these causes can be prevented by regular inspection and maintenance, while others may require professional assistance. It is important to note that GFCI devices (ex. thermostat, breakers, outlets) should be tested regularly as these do wear out over time.

Did you find this helpful? Yes No

Publications and Manuals



Specifications


Warranty / Certifications

Approvals cULus listed
Ingress Protection (IPxx) Rating IP20
UL Listing Number E157297
Warranty Limited 3-year warranty and lifetime technical support

Appearance

Color White Acrylic

Electrical

Connection 4 wires, double pole
Connection Method Hardwired
Ground Fault Protection GFCI, Class A, 5 mA
Maximum Current 15 A
Maximum Power 1800 W @ 120 V, 3120 W @ 208 V, 3600 W @ 240 V
Supply 120 VAC, 208 VAC, 240 VAC (50/60Hz)

Product Dimensions

Depth 1.73″
Installed Depth 0.46″
Length 4.98″
Weight 0.4 lbs
Width 3.09″

Identifiers

SKU USG5-4000
UPC (GTIN-12) 881308080433