nJoin 2.0 Power Module with Class A GFCI (USG5-4000)

nJoin 2.0 Power Module with Class A GFCI (USG5-4000)

Part Number: USG5-4000
This support page provides publications, manuals, specifications, videos, support articles, and common support questions

Support Questions

Showing all 3 questions

A GFCI/GFEP (Ground Fault Circuit Interrupter / Ground Fault Equipment Protection) works differently than a circuit breaker by specifically detecting a small imbalance in electrical current between the hot and neutral wires, which indicates a potential ground fault (like a person touching a live wire), and instantly shutting off the power to prevent shock, while a circuit breaker only trips when there's a significant overload in current flow on the circuit, like a short circuit or too many appliances plugged in.

3 people found this helpful Was this helpful? Yes No

Relays can fail due to excessive current or voltage. When a relay is exposed to too much current, the contacts can burn out. High voltage can also damage the coil. Other reasons include mechanical wear and tear, dust or dirt buildup, and moisture. These factors can cause the relay to malfunction or stop working entirely. Regular maintenance and using the relay within its specified limits can help prevent failures.

2 people found this helpful Was this helpful? Yes No

GFCI can fail for various reasons, such as wear and tear, moisture, corrosion, power surges, faulty wiring, or improper installation. Some of these causes can be prevented by regular inspection and maintenance, while others may require professional assistance. It is important to note that GFCI devices (ex. thermostat, breakers, outlets) should be tested regularly as these do wear out over time.

Was this helpful? Yes No


Specifications

Warranty / Certifications

Approvals cULus listed
Ingress Protection (IPxx) Rating IP20
UL Listing Number E157297
Warranty Limited 3-year warranty and lifetime technical support

Appearance

Color White Acrylic

Electrical

Connection 4 wires, double pole, screw terminals
Connection Method Hardwired
Ground Fault Protection GFCI, Class A, 5 mA
Maximum Current 15 A
Maximum Power 1800 W @ 120 V, 3120 W @ 208 V, 3600 W @ 240 V
Supply 120 VAC, 208 VAC, 240 VAC (50/60Hz)

Product Dimensions

Depth 1.73″
Installed Depth 0.46″
Length 4.98″
Weight 0.6 lbs
Width 3.09″

Identifiers

SKU USG5-4000
UPC (GTIN-12) 881308080433