nJoin 2.0 Power Module with Class A GFCI (USG5-4000)
This support page provides publications, manuals, specifications, videos, support articles, and common support questions
Support Questions
Showing all 3 questions
A GFCI/GFEP (Ground Fault Circuit Interrupter / Ground Fault Equipment Protection) works differently than a circuit breaker by specifically detecting a small imbalance in electrical current between the hot and neutral wires, which indicates a potential ground fault (like a person touching a live wire), and instantly shutting off the power to prevent shock, while a circuit breaker only trips when there's a significant overload in current flow on the circuit, like a short circuit or too many appliances plugged in.
Relays can fail due to excessive current or voltage. When a relay is exposed to too much current, the contacts can burn out. High voltage can also damage the coil. Other reasons include mechanical wear and tear, dust or dirt buildup, and moisture. These factors can cause the relay to malfunction or stop working entirely. Regular maintenance and using the relay within its specified limits can help prevent failures.
GFCI can fail for various reasons, such as wear and tear, moisture, corrosion, power surges, faulty wiring, or improper installation. Some of these causes can be prevented by regular inspection and maintenance, while others may require professional assistance. It is important to note that GFCI devices (ex. thermostat, breakers, outlets) should be tested regularly as these do wear out over time.
Documents
Wiring Diagrams
- nJoin (USG-4000), nJoin 2.0 (USG5-4000) Power Module Wiring Diagram (English)
- Wiring Diagram for 120V & 240V Floor Heating Products with Relay with Thermostat (English)
Technical Specifications
Technical Information
Operation Manuals
Sell Sheets
Specifications
Warranty / Certifications
| Approvals | cULus listed |
| Ingress Protection (IPxx) Rating | IP20 |
| UL Listing Number | E157297 |
| Warranty | Limited 3-year warranty and lifetime technical support |
Appearance
| Color | White Acrylic |
Electrical
| Connection | 4 wires, double pole, screw terminals |
| Connection Method | Hardwired |
| Ground Fault Protection | GFCI, Class A, 5 mA |
| Maximum Current | 15 A |
| Maximum Power | 1800 W @ 120 V, 3120 W @ 208 V, 3600 W @ 240 V |
| Supply | 120 VAC, 208 VAC, 240 VAC (50/60Hz) |
Product Dimensions
| Depth | 1.73″ |
| Installed Depth | 0.46″ |
| Length | 4.98″ |
| Weight | 0.6 lbs |
| Width | 3.09″ |
Identifiers
| SKU | USG5-4000 |
| UPC (GTIN-12) | 881308080433 |
Videos
Articles
- Companies that allow EFH under LVT
- Different types of wood and Electric Floor Heating
- EMF, Floor Heat and Pacemakers
- ETI Floor Heating Control FWT-3 Thermostat
- FLOR Carpet Squares and EFH
- Heating LVT, Vinyl, and VCT
- How to Extend Leads For Floor Heating Products
- How To Prevent Wood Floor Gaps
- Only Some Floor-Heating Zones Heat After Replacing a Thermostat with nJoin Power Modules