PRO-Tect: Pipe Freeze Protection Single-Zone Control with GFEP


Part Number: PT-SINGLE
This support page provides publications, manuals, specifications, videos, support articles, and common support questions


question-mark
Common Support Questions (14)

publication
Publications and Manuals (7)

specifications
Specifications (21)

Videos (3)

Articles (2)

Related Items (10)

Create a new Support Request

Shop Now

Common Support Questions


Unfortunately there's no set answer for this because it depends on many factors such as the diameter of the pipes, the installation density of the heating cables, the outdoor temperature, the installation of thermal insulation sleeves, etc.

There are too many variables to provide an accurate answer. Even though this product is designed to keep pipes from freezing, it is not designed to thaw pipes. If your pipe has frozen with the heat tape installed and energized, please check the placement of the built-in thermostat and verify that the insulation has been properly installed and waterproofed.

Need more help? View support options

Yes, it can be used for both application types to prevent pipes from freezing and bursting during cold weather.

Need more help? View support options

Never spiral heating cable around pipes. Attach self regulating cable in straight runs at the 8 o'clock position, or if two runs are required (pipes greater than 12“ diameter) attach the cable at the 8 o'clock and the 4 o'clock positions. Please refer to the installation manual for further information.

Need more help? View support options

Yes, you can extend the sensor up to 2,000 ft. cable for enhanced installation options

Need more help? View support options

WarmlyYours offers a conversion kit (SR-PLUG-KIT) to enable a plug-in requirement. This kit includes ground fault equipment protection (GFEP). The receptacle must be 120V, grounded, and approved for wet locations if located outside. The self regulating cable must not exceed 140‘ in length.

Need more help? View support options

Yes, you can use a 3-wire RTD Sensor: Platinum, Alpha = 0.00385, ITS–90,100 ohms. Once it is installed you will need to configure the controller for it by navigating to the sensor type screen and changing it to RTD.

Need more help? View support options

WarmlyYours does not recommend using an extension cord for permanent installations. Pipe heat should always be plugged directly into a receptacle or hardwired to the circuit that is powering it.

Need more help? View support options

No. Only install pipe heat (heat trace cable) in accessible locations. Do not install this self regulating cable in walls or any place where the cable is hidden. Do not run it through walls, ceilings, or floors. The cable must be installed 10“ away from combustible surfaces, such as wood, and it should not be embedded in insulation or roofing material.

Need more help? View support options

Do not wrap self regulating cable around the pipe in a coiled or spiral fashion, and do not use electric tape to attach it. WarmlyYours recommends attaching the cable in a straight run and to use aluminum or fiberglass tape, pipe straps, or plastic zip ties to attach the cable. Then cover the assembly with fire-resistant insulation and assure it is waterproof. Place electrical heating cable WARNING labels every 10‘, and where the label will be clearly visible.

Need more help? View support options

Use plastic zip ties, aluminum or fiberglass tape, or pipe straps. Do NOT use vinyl electrical tape, masking tape or duct tape. Do NOT use metal wire or metal twist ties to attach the cable.

Need more help? View support options

Ice Shield is 120V or 240V and outputs 5W/ft, and is designed for roof and gutter deicing.
PRO-Tect is 120V or 240V and outputs 5W/ft, 8W/ft, or 10W/ft, and is designed for pipe freeze protection.

Need more help? View support options

The GPT-130 displays a number of alarms, beside the ground fault it will also alarm for low current. If you have disconnected the load to trouble shoot a possible ground fault in the heater cable, then you probably have a Low Current Alarm and a very low default ground fault current reading.

You can tell the difference by looking closely at the display, it will tell you what the alarm is for. If you want to clear the low current alarm so you can test the controller then go into the configuration menu and disable the Low Current Alarm.

Remember to re-enable the Low Current Alarm when you are done testing and ready to put the unit back into service.

Need more help? View support options

This would indicate that you have enabled the Low Temperature Alarm and that the current temperature the sensor is sensing is below the alarm setpoint. You can change the set point, wait for the heaters to warm the sensor, or disable the alarm.

Need more help? View support options


Publications and Manuals



Specifications


Electrical

Activation Temperature -99.9 to 999 °F
Connection Method Hardwired
Ground Fault Equipment Protection (GFEP) Self-test GFEP (Adjustable 1-300mA)
Maximum Load (Resistive Only) 30 A
Voltage 100 - 277 VAC

Warranty / Certifications

Approvals UL and CSA listed
Area of Use Non-hazardous locations
Ingress Protection (IPxx) Rating IP66
Warranty 2 years
Waterproofing NEMA 4X

Features

Built-in GFI Self-test GFEP (Adjustable 1-300mA)
Indicators 2.7″ Display
Temperature Setpoint Adjustable −99.9 °F to 999 °F

Logistics

Country of Origin (COO) United States of America

Product Dimensions

Depth 4.375″
Height 5.5″
Installed Depth 0.75″
Width 8.125″

Thermostat

Included Sensor 100k ohms, 20' lead

Identifiers

SKU PT-SINGLE
UPC (GTIN-12) 881308058319

Videos



Articles




Speak to a radiant heating expert


Can’t find what you’re looking for? Create a Support Request