ThermalSheet Insulating Underlayment (2′ x 3′) - 6 Sq. Ft. - 1 Sheet

ThermalSheet Insulating Underlayment (2′ x 3′) - 6 Sq. Ft. - 1 Sheet

Part Number: TS-SH6MM-24x36
This support page provides publications, manuals, specifications, videos, support articles, and common support questions

Notices

Quebec Repairability Notice

Avis important pour les consommateurs du Québec:

WarmlyYours n’offre pas de services de réparation pour ce produit. Les seules pièces de rechange disponibles sont les kits de raccordement (splice kits) ; l’élément chauffant lui-même n’est pas offert comme pièce de rechange. Si votre système de chauffage par le sol intérieur tombe en panne pendant la période de garantie, nous remplacerons l’unité complète conformément à notre politique de garantie. Notre équipe d’assistance technique est disponible 24h/24 et 7j/7 par téléphone pour toute aide à l’installation ou au dépannage. Pour plus de détails, consultez notre politique de retour. Cet avis est fourni conformément à la Loi sur la protection du consommateur du Québec, article 39 (telle qu’amendée en 2025).

Important Notice for Québec Consumers:

WarmlyYours does not provide repair services for this product. The only replacement parts available are splice kits; the heating element itself is not available as a replacement part. If your indoor floor heating system fails within the warranty period, we will replace the entire unit according to our warranty policy. Our technical support team is available 24/7 by phone for installation and troubleshooting assistance. For full details, see our Return Policy. This notice is provided in accordance with Québec’s Consumer Protection Act, section 39 (as amended in 2025).


Support Questions

Showing 10 of 12 questions

No, for the installation of an Environ heating system with a floating floor like laminate, it is not necessary to adhere the ThermalSheet underlayment to the subfloor. The underlayment should instead be allowed to float freely on the subfloor. Make sure to stagger adjacent sheets of underlayment and tape them together to prevent any overlaps, ensuring a flat and even layer beneath your flooring. This method helps accommodate the natural expansion and contraction of the floating floor.

1 person found this helpful Was this helpful? Yes No

Yes, unlike natural cork, ThermalSheet will not expand from self leveling cement (SLC).

1 person found this helpful Was this helpful? Yes No

ThermalSheet Insulating Underlayment is a synthetic cork, a lightweight thermal barrier made of hemi-crystalline thermoplastic.

WarmlyYours recommends ThermalSheet underlayment when installing a floor heating system over a concrete slab to prevent heat loss and protect against moisture. It will not rot, support mold and mildew, or absorb moisture.

- ThermalSheet synthetic cork underlayment (6mm) has a 1.5 R-value, crack isolation up to 1/4“, reduces sound by up to 22 dB, and is Robinson tested (TCNA) and rated for residential loads.

- Cork (6mm) has a .72 R-value, crack isolation up to 1/32“, reduces sound by up to 23 dB, and is Robinson tested (TCNA) and rated for residential loads.

Was this helpful? Yes No

Yes. The floor never free-runs — the thermostat’s floor sensor governs output, and you set a maximum floor temperature limit in the thermostat itself. Most heated tile bathroom floors are set between 80°F and 85°F. Set that limit during commissioning and record it on the handoff sheet so the homeowner does not raise it past the flooring manufacturer’s rated maximum.

Was this helpful? Yes No

No. Put a skim coat of SLC (Self-Leveling Cement), or even plywood over it first. Then, the vinyl flooring product can be installed.

Was this helpful? Yes No

Yes, but the tear-out is the real risk. Scan the floor with thermal imaging before demo to map the existing hydronic tubing, and never fasten or drill into it. Keep the two systems on fully independent controls so they cannot fight each other, and do not place the electric floor sensor directly above a hydronic loop — the false-high reading will short-cycle the electric system. Call PRO technical support at 800-875-5285 to review the assembly before ordering.

Was this helpful? Yes No

No. Electric floor heating cable is listed for installation under floor coverings only, and NEC 424.38(A) does not permit heating cable to be installed in walls. Running it vertically voids both the UL listing and the warranty. For warm towels and a little extra room heat, specify a heated towel rack, which is designed and listed for wall mounting.

Was this helpful? Yes No

Yes, all pressure-sensitive adhesives are fine.

Was this helpful? Yes No

Yes, ThermalSheet should be bonded to the subfloor with any high quality modified thin-set, or with a bond coat adhesive. Further installation information can be found in the installation manual. 

Was this helpful? Yes No

No separate GFCI breaker is required — every WarmlyYours thermostat has a built-in Class A (5mA) GFCI. Stacking a GFCI breaker on top of it is one of the most common causes of nuisance tripping. Run a dedicated breaker sized to the load at 80% continuous duty: a 15A circuit carries up to 1,440W at 120V, a 20A circuit up to 1,920W. Loads beyond the thermostat’s 15A rating need a power module or relay.

Was this helpful? Yes No

ThermalSheet does not have a “shiny” side vs. non-shiny side.  It is uniform synthetic XPS foam underlayment board with a cementitious facing on both sides.  Either side can face up or down. 

Was this helpful? Yes No

The best home features for cold climates include a simple gable roof to shed snow, covered entrances for protection, airtight triple-pane windows to prevent heat loss, and radiant heating systems. These features work together to maintain interior warmth, reduce energy bills by up to 25%, and ensure structural safety during harsh winters.

Was this helpful? Yes No


Specifications

Insulation Specification

Acoustic testing on 6" slab, no ceiling IIC 52 wood construction. FIIC 59 - 7.5″ concrete slab. ΔIIC 20 - 6″ concrete slab
Compressive Strength 41 psi at 25% strain, 54 psi at 50% strain, and 110 psi at 75% strain
Material Expanded Polypropylene (EPP)
Thermal Insulation 1.5 R-Value

Product Dimensions

Coverage 6 ft²
Depth 0.24″
Length 36″
Weight 0.4 lbs
Width 24″

Identifiers

SKU TS-SH6MM-24x36
UPC (GTIN-12) 881308077037

Warranty / Certifications

TCNA Robinson test Residential
Warranty 5 years