Waterproof Outdoor Thermostat for Pipe Freeze Protection or Roof and Gutter Deicing Systems

Waterproof Outdoor Thermostat for Pipe Freeze Protection or Roof and Gutter Deicing Systems

Part Number: AIR-STAT
This support page provides publications, manuals, specifications, videos, support articles, and common support questions

Support Questions

Showing all 2 questions

GFEP is the National Electric Code (NEC) required protection for fixed outdoor deicing and snow-melting equipment, which may be accomplished by using circuit breakers equipped with ground-fault equipment protection (GFEP) of 30 mA. It is important to understand that this required equipment protection is NOT the same as a 5 mA GFCI used for personal protection.

11 people found this helpful Was this helpful? Yes No

A 2 pole single-phase 240V circuit works by continuously monitoring the current flowing through both hot wires of the circuit. If it detects even a slight imbalance between the current on each hot wire (indicating a ground fault), it will quickly trip, cutting off power to the circuit. Essentially, it compares each leg of the 240V circuit and trips if they are not precisely equal.

1 person found this helpful Was this helpful? Yes No


Specifications

Electrical

Activation Temperature 40 °F
Connection Method Hardwired
Maximum Load (Resistive Only) 22 A
Voltage 125, 250, and 480 VAC

Warranty / Certifications

Approvals UL and CSA listed
Area of Use Non-hazardous locations
Ingress Protection (IPxx) Rating IP66
Warranty 2 years
Waterproofing NEMA 4X

Product Dimensions

Depth 2½″
Height 3¼″
Installed Depth 0.75″
Weight 1.2 lbs
Width 5¼″

Thermostat

Included Sensor 1 capillary bulb, 3′ lead

Identifiers

SKU AIR-STAT
UPC (GTIN-12) 881308056018



Speak to a radiant heating expert


Can’t find what you’re looking for? Create a Support Request