Contact Us After Hours

Loading...

Loading contact options...

Sign In

Loading...

Loading...


Snow and Ice Melting Control Premium (SCP-120)

Snow and Ice Melting Control Premium (SCP-120)

Part Number: SCP-120
This support page provides publications, manuals, specifications, videos, support articles, and common support questions

Notices

Quebec Repairability Notice

Avis important pour les consommateurs du Québec:

WarmlyYours ne fournit ni services de réparation ni pièces de rechange pour ce produit. Si votre thermostat de chauffage de sol intérieur tombe en panne pendant la période de garantie, nous remplacerons l'unité complète conformément à notre politique de garantie. Notre équipe de soutien technique est disponible par téléphone 24h/24 et 7j/7 pour l'assistance à l'installation et au dépannage. Pour tous les détails, veuillez consulter notre Politique de Retour. Cet avis est fourni conformément à l'article 39 de la Loi sur la protection du consommateur du Québec (telle que modifiée en 2025).

Important Notice for Québec Consumers:

WarmlyYours does not provide repair services or replacement parts for this product. If your indoor floor heating thermostat fails within the warranty period, we will replace the entire unit according to our warranty policy. Our technical support team is available 24/7 by phone for installation and troubleshooting assistance. For full details, see our Return Policy. This notice is provided in accordance with Québec’s Consumer Protection Act, section 39 (as amended in 2025).


Support Questions

Showing 10 of 11 questions

Our systems can handle low temperatures, but many controls come equipped with a Low-Temperature Lockout Feature. This feature prevents the system from running in very low temperatures. At very low temperatures it can become difficult for the system to effectively melt the snow. It is however possible to turn off this feature should you need the system to keep running during such low temperatures.

14 people found this helpful Was this helpful? Yes No

All of our automatic controllers have a Hold-on time feature after the initial warming up of the snow melt system. This feature ensures that all the snow is melted from the surface, and also that the system continues to operate and evaporate the surface water without it refreezing.

9 people found this helpful Was this helpful? Yes No

When the design requirement's amp draw exceeds the selected controller's capacity.

5 people found this helpful Was this helpful? Yes No

Once you've decided what type of heating system (manual vs. automatic), you'll need to choose a control, which may or may not utilize a sensor. You may need a relay panel(s) depending on the size of the system, and a snow melt plaque which is required by the National Electric Code. Junction box(es) may be optional depending on the distance of heating cable from the indoor power location.

2 people found this helpful Was this helpful? Yes No

It depends on how the system is intended to operate. If the expectation is manual operation (ex. WiFi or Timer Control), then no sensors are required. If the expectation is automatic operation, then the system will require at least one snow sensor.

2 people found this helpful Was this helpful? Yes No

Ground fault equipment protection (GFEP) is intended to provide protection for equipment against damaging line-to-ground currents by disconnecting all ungrounded conductors of the faulted circuit.

2 people found this helpful Was this helpful? Yes No

No, a sensor is not required with the snow melt system. However, certain automatic controllers require a temperature/moisture sensor to sense atmospheric conditions and may also require an in-slab, high temperature limit sensor to be installed (notably, asphalt installations).

1 person found this helpful Was this helpful? Yes No

It can go outdoors provided weatherproof fittings are used.  The optional RCO switch should be considered for remote operation from an indoor location.

1 person found this helpful Was this helpful? Yes No

A 2 pole single-phase 240V circuit works by continuously monitoring the current flowing through both hot wires of the circuit. If it detects even a slight imbalance between the current on each hot wire (indicating a ground fault), it will quickly trip, cutting off power to the circuit. Essentially, it compares each leg of the 240V circuit and trips if they are not precisely equal.

1 person found this helpful Was this helpful? Yes No

This feature prevents the snow melting system from running, by default, in temperatures below 17°F (–8.33°C), or as set by the user. At temperatures this low, it becomes difficult for the system to effectively melt the snow. It is, however, possible to turn off this feature should the system be required to keep running during these low temperatures.

1 person found this helpful Was this helpful? Yes No

The AIR-SS-2 can be mounted at a distance up to 500 feet away from the controller using 22-gauge wires and up to 1000 feet using 18-gauge wires.

Was this helpful? Yes No


Specifications

Warranty / Certifications

Approvals cULus listed
Area of Use Non-hazardous locations
Warranty 2 years
Waterproofing NEMA 3R

Installation

Best Use Best For Asphalt Projects

Electrical

Building Automation Interface Dry relay contacts: Override On and Override Off inputs; Supply, Snow, Heat and High Temperature outputs
Compatible Sensors and Accessories RCO, AIR-SS, AIR-SS-2, GTR-SS, SC-SS-PAV-6E-KIT
Connection Method Hardwired
Control Options Automatic with manual override
Max Number of Sensors 6
Max Sensor Wire Length 500 ft (152 m) with 18 AWG 3-wire jacketed cable
Maximum Current 24 A
Mounting Method Wall Mounted
Voltage 120 V

Product Dimensions

Depth 6.562 in / 167 mm
Height 9.125 in / 232 mm
Weight 9 lbs
Width 11.5 in / 292 mm

Construction

Operating Temperature Range -40°F to 160°F (-40°C to 71°C)

Logistics

Package Contents SCP-120 control panel (Qty 1), high-limit temperature sensor with 20′ lead (Qty 1)

Identifiers

SKU SCP-120
UPC (GTIN-12) 881308020613




Speak to a radiant heating expert


Can’t find what you’re looking for? Create a Support Request