Transformer 500VA 33sqft Q-Tran (TR-500VA-Q)
This product is discontinued.
This support page provides publications, manuals, specifications, videos, support articles, and common support questions
Support Questions
Showing all 5 questions
A GFCI/GFEP (Ground Fault Circuit Interrupter / Ground Fault Equipment Protection) works differently than a circuit breaker by specifically detecting a small imbalance in electrical current between the hot and neutral wires, which indicates a potential ground fault (like a person touching a live wire), and instantly shutting off the power to prevent shock, while a circuit breaker only trips when there's a significant overload in current flow on the circuit, like a short circuit or too many appliances plugged in.
Relays can fail due to excessive current or voltage. When a relay is exposed to too much current, the contacts can burn out. High voltage can also damage the coil. Other reasons include mechanical wear and tear, dust or dirt buildup, and moisture. These factors can cause the relay to malfunction or stop working entirely. Regular maintenance and using the relay within its specified limits can help prevent failures.
If your floor is not heating and your thermostat is functioning properly, test to see if proper voltages are present at the transformer. If 24 VAC is not being returned by the transformer, then it either needs to be replaced or checked to ensure that the internal secondary circuit breakers have not been tripped and are functioning properly. Contact WarmlyYours technical support at 1-800-875-5285 for further assistance.
GFCI can fail for various reasons, such as wear and tear, moisture, corrosion, power surges, faulty wiring, or improper installation. Some of these causes can be prevented by regular inspection and maintenance, while others may require professional assistance. It is important to note that GFCI devices (ex. thermostat, breakers, outlets) should be tested regularly as these do wear out over time.
Documents
Installation
Wiring Diagrams
Technical Information
Specifications
Electrical
| Breaker Amperage | 25 Amps |
| Connection Method | Hardwired |
| Output Wattage | 500 Watts |
| Power | 120V |
| Voltage (Output) | 24 VAC |
Product Dimensions
| Depth | 7″ |
| Height | 11″ |
| Weight | 17.55 lbs |
| Width | 4.5“ |
Identifiers
| SKU | TR-500VA-Q |
| UPC (GTIN-12) | 881308010676 |
Videos
Articles
- Choosing wood flooring for electric radiant heating
- Electric radiant heat under LVT, vinyl and resilient flooring
- ETI Floorstat FWT-3: operation and replacement considerations
- Extending floor-heater cold leads and sensor wiring
- Finding LVT products compatible with electric floor heating
- Floor heating and implanted pacemakers: checking compatibility
- FLOR carpet tiles over radiant floor heating
- How to reduce winter gaps in wood flooring