Transformer 500VA 33sqft Q-Tran (TR-500VA-Q)

Transformer 500VA 33sqft Q-Tran (TR-500VA-Q)

Part Number: TR-500VA-QPast Model
This product is discontinued.
This support page provides publications, manuals, specifications, videos, support articles, and common support questions

Support Questions

Showing all 5 questions

A GFCI/GFEP (Ground Fault Circuit Interrupter / Ground Fault Equipment Protection) works differently than a circuit breaker by specifically detecting a small imbalance in electrical current between the hot and neutral wires, which indicates a potential ground fault (like a person touching a live wire), and instantly shutting off the power to prevent shock, while a circuit breaker only trips when there's a significant overload in current flow on the circuit, like a short circuit or too many appliances plugged in.

3 people found this helpful Was this helpful? Yes No

Relays can fail due to excessive current or voltage. When a relay is exposed to too much current, the contacts can burn out. High voltage can also damage the coil. Other reasons include mechanical wear and tear, dust or dirt buildup, and moisture. These factors can cause the relay to malfunction or stop working entirely. Regular maintenance and using the relay within its specified limits can help prevent failures.

2 people found this helpful Was this helpful? Yes No

If your floor is not heating and your thermostat is functioning properly, test to see if proper voltages are present at the transformer.  If 24 VAC is not being returned by the transformer, then it either needs to be replaced or checked to ensure that the internal secondary circuit breakers have not been tripped and are functioning properly.  Contact WarmlyYours technical support at 1-800-875-5285 for further assistance.

Was this helpful? Yes No

Poor maintenance, overheating, insulation breakdown, and vermin damage are common causes.

Was this helpful? Yes No

GFCI can fail for various reasons, such as wear and tear, moisture, corrosion, power surges, faulty wiring, or improper installation. Some of these causes can be prevented by regular inspection and maintenance, while others may require professional assistance. It is important to note that GFCI devices (ex. thermostat, breakers, outlets) should be tested regularly as these do wear out over time.

Was this helpful? Yes No


Specifications

Electrical

Breaker Amperage 25 Amps
Connection Method Hardwired
Output Wattage 500 Watts
Power 120V
Voltage (Output) 24 VAC

Product Dimensions

Depth 7″
Height 11″
Weight 17.55 lbs
Width 4.5“

Identifiers

SKU TR-500VA-Q
UPC (GTIN-12) 881308010676