Prodeso Membrane Roll 162 Sq. Ft. (3′ 3.4″ x 49′ 2.6″)

4.94
Based on 81 reviews



Request a Free Product Sample
Support Page

Features

  • Complete installations in a day

  • Holds TempZone Cable securely

  • Prevents cracks and extends floor life

  • Waterproof with ProBand accessories

  • Low profile for minimal height increase

Prodeso Cable Installation Membrane Description

The Prodeso Cable Installation Membrane is an uncoupling membrane that is designed to be used with TempZone electric floor heating cable*. This 161.59 sq. ft. roll of the membrane is great for use in larger projects. 

The unique design of the membrane allows for greatly accelerated installations of radiant floor heating—in fact, most floor heating installs with this membrane can be completed in a single day.

The polypropylene membrane features integrated channels are shaped to easily and securely hold the 3.7-watt TempZone Heating Cable. This makes it easy to maintain proper spacing throughout an entire project. The Prodeso membrane also provides uncoupling and crack isolation benefits, which can greatly extend the life of tile, marble, and stone floors. With the use of ProBand accessories, the membrane can also be waterproofed for high-moisture applications like kitchens or bathrooms. The low 7/32” profile of this membrane means its installation won’t significantly increase overall floor height. The membrane comes with a 10-year warranty.  

* TempZone electric floor heating cable sold separately. 

Specifications

Product Dimensions

Coverage 161.59 ft²
Length 49′ 2.6″
Stud Spacing 1¼″
Thickness 7/32″
Weight 34 lbs
Width 3′ 3.4″

Installation

Minimum Tile Size 2″ x 2″
Recommended Cable Spacing 3¾″, 5″

Identifiers

SKU TC-MEM-BL-162
UPC (GTIN-12) 881308051426

Appearance

Type Membrane

Warranty / Certifications

Warranty 10 years

Frequently Asked Questions

Showing all 5 questions

Waterproofing for the room is in the layer above the floor heating system. The layers for waterproofing this type of floor are:

  • subfloor
  • thinset
  • uncoupling membrane
  • tempzone heating cable
  • waterproofing tape for seams and corners
  • thinset or self leveling cement
  • tile floor
5 people found this helpful
Was this helpful?

Insulating underlayments and uncoupling membranes share some key characteristics like providing crack isolation benefits, but they are separated by their primary functions.

Insulating underlayments, like WarmlyYours ThermalSheet, provide a thermal break between a subfloor and the heating elements, which can help prevent the concrete from acting as a “heat sink” and increase energy efficiency. ThermalSheet has a 1.5 R-value, and it offers crack isolation of up to ¼”. This can be particularly beneficial if you are trying to heat a room above a cement slab or above an unheated garage. 

Uncoupling membranes, like the Prodeso membrane, are great for protecting relatively fragile floor coverings like tile from foundational movement. They also allow for faster installation times than many other types of floor heating.

4 people found this helpful
Was this helpful?

The height of the membrane itself is just about 1/4" (7/32").

3 people found this helpful
Was this helpful?

This membrane provides many benefits including speedy installation, uncoupling, crack isolation, vapor management, and load distribution.

1 person found this helpful
Was this helpful?

A decoupling membrane protects the installation from differential expansion/contraction between the substrate and the flooring, relieving almost all shear stresses. Crack isolation protects the installation by isolating the flooring from minor in-plane substrate cracking.