WarmlyYours self-regulating roof and gutter de-icing cable can be used on rubber or EPDM (Ethylene Propylene Diene terpolyMer) roofs.

The primer that WarmlyYours sells is specifically for adhering clips to EPDM or rubber roofing.

1 person found this helpful Was this helpful? Yes No

A 2 pole single-phase 240V circuit works by continuously monitoring the current flowing through both hot wires of the circuit. If it detects even a slight imbalance between the current on each hot wire (indicating a ground fault), it will quickly trip, cutting off power to the circuit. Essentially, it compares each leg of the 240V circuit and trips if they are not precisely equal.

1 person found this helpful Was this helpful? Yes No

No.  Aluminum 3-prong clips can cause rapid galvanic corrosion if they come in direct contact with copper.  WarmlyYours recommends using our Self-Regulating roof & gutter cable fastened with 3-prong Copper clips (ET-CL-CU-P25) and double-sided adhesive pads (ET-VHB-PAD-P25) for this application.

Was this helpful? Yes No