No. They are not designed to be powered by DC voltage. They must be used with AC voltage.
Need more help? View support options
Electric-resistance heating cables and systems have no polarity. This includes all current WarmlyYours heating elements.
Need more help? View support options
By attaching a heating cable to the exterior of a pipe, it will transfer the heat to the pipe to prevent frozen pipes. And with the use of pipe insulation the heat will be evenly spread and won't dissipate as quickly.
Need more help? View support options
No, as long as it's properly installed. However, improper installation, use, and/or maintenance of electrical heating cable can cause fires, electric shock, and/ or frozen pipes.
Need more help? View support options
As the names imply, constant wattage cable uses fixed wattage output per linear foot and does not automatically adjust in response to temperature changes. Self-regulating cable is manufactured with a resistance matrix placed between its 2 buss wires that varies the ohms resistance per linear foot to automatically adjust in response to temperature changes. Learn more about this in our blog Self-Regulating vs. Constant Wattage Heating Cables.
Need more help? View support options
Heat trace, heat tape, or heating cable for pipes is typically an electric heating cable that can be attached to the pipe which helps keep non-flowing water pipes in poorly insulated perimeter walls flowing despite harsh winter temperatures.
Need more help? View support options
Unfortunately there's no set answer for this because it depends on many factors such as the diameter of the pipes, the installation density of the heating cables, the outdoor temperature, the installation of thermal insulation sleeves, etc.
Need more help? View support options
Amps | 4.17 A |
Benefits | Can be cut-to-length & overlapped |
Cable Type | Self Regulating |
Connection Method | Hardwired |
Voltage | 120 VAC |
Watts Per Ft. at 50°F/10°C | 10 W |
Approvals | cULus & cCSAus Listed |
Warranty | 10 years |
Cable Cross Section | 0.42″ x 0.23″ / 10.7mm x 5.84mm |
Cable Jacket | Waterproof thermoplastic |
Length | 50 ft |
Weight | 3.6 lbs |
Maximum Intermittent Exposure Temperature, 1000 Hours (Power On or Off) | 185ºF / 85ºC |
Maximum Maintain or Continuous Exposure Temperature (Power On) | 149ºF / 65ºC |
Minimum Bend Radius | 1.125″ / 28.6mm |
Minimum Installation Temperature | 0°F / -18°C |
SKU | PT-SR-120-10-0050 |
UPC (GTIN-12) | 881308067885 |