Waterproof Outdoor Thermostat Support
Support Questions
Showing 10 of 16 questions
Heat tape is electrical equipment: improper installation, damaged cable, or misuse can cause fire or electric shock. Select cable approved for your pipe and location, follow its layout and insulation requirements, provide the specified electrical protection, and inspect it before each cold season. Do not use damaged equipment or overlap cable unless the exact product instructions permit it.
Pipe heat tape is intended for freeze prevention, not as a guaranteed way to thaw an already frozen pipe. A frozen pipe may be damaged. Have the plumbing assessed and thawed safely by a qualified professional; never use an open flame. Before future cold weather, verify cable selection, thermostat placement, insulation, and electrical protection.
Cable temperature depends on the product, surrounding conditions, installation, and controls. Do not assume a universal surface-temperature range. Follow the exact cable and pipe manufacturers’ limits, particularly for plastic pipe, and use the specified insulation and thermostat placement.
Pipe heat tape electricity use depends on cable length, power output, run time, and controls. For a fixed-output cable, watts = length in feet × W/ft. A 30-foot, 7 W/ft kit draws 210 watts while energized; eight energized hours uses 1.68 kWh. Multiply by your local rate for cost. Thermostat duty cycle and self-regulating output change actual consumption.
Never spiral heating cable around pipes. Attach self regulating cable in straight runs at the 8 o'clock position, or if two runs are required (pipes greater than 12“ diameter) attach the cable at the 8 o'clock and the 4 o'clock positions. Please refer to the installation manual for further information.
WarmlyYours offers a conversion kit (SR-PLUG-KIT) to enable a plug-in requirement. This kit includes ground fault equipment protection (GFEP). The receptacle must be 120V, grounded, and approved for wet locations if located outside. The self regulating cable must not exceed 140‘ in length.
No. Only install pipe heat (heat trace cable) in accessible locations. Do not install this self regulating cable in walls or any place where the cable is hidden. Do not run it through walls, ceilings, or floors. The cable must be installed 10“ away from combustible surfaces, such as wood, and it should not be embedded in insulation or roofing material.
Do not wrap self regulating cable around the pipe in a coiled or spiral fashion, and do not use electric tape to attach it. WarmlyYours recommends attaching the cable in a straight run and to use aluminum or fiberglass tape, pipe straps, or plastic zip ties to attach the cable. Then cover the assembly with fire-resistant insulation and assure it is waterproof. Place electrical heating cable WARNING labels every 10‘, and where the label will be clearly visible.
Documents
Installation
- Pro Tect Pipe Freeze Protection Self Regulating Heating Cable Install Manual (English)
- SR-PLUG-KIT Plug-in Conversion Kit with Ground Fault Equipment Protection (GFEP) Installation Manual (English)
- Roof And Gutter Cable Installation Manual (French)
- Roof And Gutter Cable Installation Manual (Spanish)
- SR-PWR-Kit Power Connection Kit Installation Manual (English)
Project Planners
Technical Information
- PRO-Tect Pipe Freeze Protection Self Regulating Heating Cable Power Connection Kit Spec Sheet (English)
- Self-Regulating Pipe Freeze Protection Controls Comparison Chart USA (English)
- AIR-STAT Outdoor Thermostat Spec Sheet (English)
Technical Specifications
- PRO-Tect Pipe Freeze Protection Self Regulating Heating Cable End Seal Termination Kit Spec Sheet (English)
- PRO-Tect Self-Regulating Heat Tape for Pipes In-Line Splice Kit Spec Sheet (English)
- PRO-Tect Self-Regulating Heat Tape for Pipes T-Splice Kit Spec Sheet (English)
Sell Sheets
- PRO-Tect Self-Regulating Heat Tape for Pipes Sell Sheet USA (English)
- Air Stat Sell Sheet A (English)