Jessica was extremely helpful in helping decide which items were needed for
installation
Contact Us After Hours
Loading contact options...
Sign In
Loading...
The PT-DUAL is a control that can be used with WarmlyYours PRO-Tect Self-Regulating Heat Tape for Pipes for most commercial (non-hazardous) and residential applications that require 2 independent heater-control circuits. This control can be used for pipe freeze protection or process heating applications. Because this control comes with 2 temperature sensors and 2 built-in relays, it can independently or jointly control 2 resistive loads of up to 30-amps apiece. Another added benefit of this control is that the integrated Ground Fault Equipment Protection (GFEP) in each of the heating circuits eliminates the need for GFEP protection in a circuit panel, which can significantly save on cost. The temperature set-points for the control are adjustable from −99.9 °F to 999 °F (note: please confirm the separate temperature rating of the heating element/s you use with the control) though the included sensors have an operating range of −40 °F to 230 °F. There are 2 temperature sensor inputs and the heating circuits can operate independently or from 1 sensor.
| Activation Temperature | -99.9 to 999 °F |
| Connection Method | Hardwired |
| Ground Fault Equipment Protection (GFEP) | Self-test GFEP (Adjustable 1-300mA) |
| Maximum Load (Resistive Only) | 2 x 30 A |
| Voltage | 100 - 277 VAC |
| Approvals | UL and CSA listed |
| Area of Use | Non-hazardous locations |
| Ingress Protection (IPxx) Rating | IP66 |
| Warranty | 2 years |
| Waterproofing | NEMA 4X |
| Depth | 5.9″ |
| Height | 12.8″ |
| Installed Depth | 0.75″ |
| Weight | 5.8 lbs |
| Width | 9″ |
| Included Sensor | 2 x 100k ohms, 20′ lead |
| SKU | PT-DUAL |
| UPC (GTIN-12) | 881308058302 |
Showing all 5 questions
At a minimum: a PRO-Tect Pipe Freeze Protection Self-Regulating Cable, an End Seal kit, and a Power Connection Kit. However, we also strongly recommend a control. All of these components are directly available from WarmlyYours (along with other accessories).
Use of another manufacturer’s components will void the warranty.
WarmlyYours offers four thermostat and controller options for PRO-Tect pipe freeze protection heating systems:
All controls include the sensor, feature NEMA 4X weatherproof enclosures, and are rated for non-hazardous locations. Contact our radiant experts for help selecting the right control for your project.
GFEP stands for Ground Fault Equipment Protection. It is a safety circuit that continuously monitors the current flowing through your heating cable. If a ground fault is detected (current leaking to ground, which can indicate damaged cable insulation), the GFEP trips the circuit and shuts the system off.
GFEP is important for pipe freeze protection systems because:
The PT-ECONOMY includes a fixed 30mA GFEP. The PT-SINGLE and PT-DUAL have adjustable GFEP (1–300mA) so you can set a sensitivity level appropriate for your installation. The AIR-STAT does not include GFEP.
If your installation is in a wet or damp location, WarmlyYours recommends choosing a control with built-in GFEP for maximum protection.
The correct temperature setpoint depends on which control you have and where the sensor is installed:
Air Sensing Thermostat (AIR-STAT) — Fixed setpoint of 40°F. The system activates when air temperature drops to this level and shuts off when it warms up. No adjustment needed.
Economy Thermostat (PT-ECONOMY) — Four preset options: 30°F, 38°F, 45°F, or 50°F. For most pipe freeze protection applications, 38°F or 40°F is a good starting point—it activates the cable before pipes reach freezing temperatures.
Digital Thermostats (PT-SINGLE / PT-DUAL) — Fully adjustable. A common recommendation is to set the activation point between 35°F and 40°F if measuring air temperature near the pipes, or slightly higher (45°F–50°F) if the sensor is measuring pipe surface temperature directly.
For specific guidance on setpoint and sensor placement for your installation, contact our radiant experts—we can help you set up the system correctly for your climate and pipe location.
You need the PT-DUAL dual-zone thermostat when your pipe freeze protection installation has two independent heating circuits that you want to control from a single enclosure.
Common scenarios that require dual-zone control:
The PT-DUAL includes two sensors and two independent sets of controls in one NEMA 4X enclosure. Each zone can have its own temperature setpoint and operates independently.
If you only have one heating circuit, the PT-SINGLE is sufficient. If you are unsure how many circuits your installation requires, our free system design service will tell you exactly what you need.
Chat with us
We'll reply by email
Your recent conversations
Email you this conversation?
We couldn't confirm your browser, so the message wasn't sent — an ad blocker or privacy extension is the usual cause. Please try again, or call us on the number at the top of the page.