ICE Shield Plug-In Heat Tape Kit for Roofs & Gutters — 60 ft, 5 W/ft, 120V

ICE Shield Plug-In Heat Tape Kit for Roofs & Gutters — 60 ft, 5 W/ft, 120V

Part Number: ETC120-5W-060-WY
This support page provides publications, manuals, specifications, videos, support articles, and common support questions

Support Questions

Showing 10 of 12 questions

Electric-resistance heating cables and systems have no polarity. This includes all current WarmlyYours heating elements.

14 people found this helpful Was this helpful? Yes No

GFEP is the National Electric Code (NEC) required protection for fixed outdoor deicing and snow-melting equipment, which may be accomplished by using circuit breakers equipped with ground-fault equipment protection (GFEP) of 30 mA. It is important to understand that this required equipment protection is NOT the same as a 5 mA GFCI used for personal protection.

11 people found this helpful Was this helpful? Yes No

WarmlyYours does not recommend installing de-icing cable to remove existing ice dams or heavy snow accumulation. These systems are designed for prevention—maintaining open drainage pathways for meltwater before freezing occurs. Installing heating cables over pre-existing ice blocks is dangerous, inefficient, and will not clear the roof effectively. For best results, install your de-icing system in early fall before freezing weather begins.

5 people found this helpful Was this helpful? Yes No

NEVER use an extension cord with roof and gutter de-icing cables. Extension cords degrade in harsh outdoor environments, leading to electrical shorts, power loss, and fire hazards. De-icing cables must plug directly into an appropriately rated outdoor outlet with ground-fault equipment protection. If your setup lacks a nearby GFEP/GFCI outlet, contact a licensed electrician to install one safely before operating your heating system.

2 people found this helpful Was this helpful? Yes No

A 2 pole single-phase 240V circuit works by continuously monitoring the current flowing through both hot wires of the circuit. If it detects even a slight imbalance between the current on each hot wire (indicating a ground fault), it will quickly trip, cutting off power to the circuit. Essentially, it compares each leg of the 240V circuit and trips if they are not precisely equal.

1 person found this helpful Was this helpful? Yes No

ICE Shield self-regulating roof cable carries a 10-year warranty; plug-in roof heat tape kits carry a 3-year warranty. Service life depends on installation, exposure, and maintenance. Inspect the cable, attachments, and protection devices before each heating season and stop using damaged equipment. Warranty duration is not a guaranteed operating life.

1 person found this helpful Was this helpful? Yes No

WarmlyYours does not recommend installing de-icing systems on ribbed metal roofs. Ribbed and corrugated panel designs typically lack the flat surface area required to properly adhere standard mounting pads and clips. Without a flush mounting surface, heating cables cannot be safely secured to the roof structure. Always evaluate your roof profile and material compatibility before purchasing your de-icing cable.

Was this helpful? Yes No

No.  Aluminum 3-prong clips can cause rapid galvanic corrosion if they come in direct contact with copper.  WarmlyYours recommends using our Self-Regulating roof & gutter cable fastened with 3-prong Copper clips (ET-CL-CU-P25) and double-sided adhesive pads (ET-VHB-PAD-P25) for this application.

Was this helpful? Yes No

Do NOT use WarmlyYours constant wattage ice shield roof and gutter cable on rubber or rubber-membrane roofs.

Was this helpful? Yes No

Triangles are spaced 15" apart.

Was this helpful? Yes No

No, typically leaf guards need to be removed for the deicing cable to be installed in the gutter to work effectively.

Was this helpful? Yes No

Two good reasons for this:  

  1. Constant Wattage cables maintain a consistent heat output regardless of the surrounding temperature. Metal roofs, being highly conductive, can cause rapid temperature fluctuations which can lead to overheating and potential damage to the cable's insulation, potentially causing a fire hazard.
  2. The UL approved installation method requires self-regulating cable for metal roofs.  If not installed per UL guidelines, there is no listing and thus no warranty.
Was this helpful? Yes No


Specifications

Electrical

Amps 2.5 A
Cable Construction Twin conductor
Cable Type Constant Wattage
Conductor Insulation XLPE
Connection Method Plug-in
Ohms 48 Ω
Outer Insulation PVC
Plug-Type NEMA 5-15 (Type B)
Plug-in Cord Length 6′
Watts 300 W
Watts Per Ft. 5 W

Warranty / Certifications

Approvals cUL Listed, CSA Listed, and cETLus Listed
Warranty 2 Year Warranty

Product Dimensions

Cable Cross Section 1/4" x 3/16"
Cold Lead Length 6′
Heating Cable Length 60′
Height 0.1875″
Length 720″
Weight 2.6 lbs
Width 0.25″

Installation

Minimum Bend Radius 1″
Minimum Installation Temperature 15°F (-10°C)

Identifiers

SKU ETC120-5W-060-WY
UPC (GTIN-12) 881308053895