The WarmlyYours 120 V Integration Kit connects your radiant floor heating system to third-party controls, giving you the ability to control your TempZone™ or Environ™ systems with the stand-alone thermostat or home automation system of your choice. The 120 V Integration Kit features an electric heating relay that operates at a resistive load of 22 amps at 120 V and includes a built-in 24V/1.2VA/Class 2 transformer. The epoxy-soundproofed relay ensures quiet operation and low current consumption. This 120 V Integration Kit features 3-wire, single-pole switching and a 12 AWG terminal wire. It includes a heating command indicator light to provide at-a-glance verification of relay operation and a terminal board connection to facilitate easy installation. The Integration Kit is C-UL-US Listed and carries a 3-year warranty against manufacturer defects.
Specifications
Electrical
| Connection | Single pole, 3 wires |
| Connection Method | Hardwired |
| Maximum Load (Resistive Only) | 22 amps |
| Transformer Ratings | 24 VAC / 1.2 VA / Class 2 |
| Voltage | 120 V |
Controls
| Control Signal | 24VAC / 40mA / 1.2VA |
Identifiers
| Ground Fault Protection (GFCI) | No |
| SKU | INTEGRATION-KIT-120V |
| UPC (GTIN-12) | 881308030216 |
Product Dimensions
| Length | 0.1″ |
| Weight | 0.8 lbs |
| Width | 0.1″ |
Warranty / Certifications
| Warranty | 3 years |
Frequently Asked Questions
Showing all 5 questions
While WarmlyYours electric radiant floor heating systems are typically installed by your floor covering contractor, a licensed electrician is recommended for the final thermostat hook-up. With every quote, we provide an Installation Plan layout, together with an electrical plan that has all the info required for the electrician.
The breaker and wire sizes are selected based on the total amperage of the WarmlyYours heating system connected to a single thermostat. This information is on the WarmlyYours heating system's installation plan, electrical plan, or UL label. Based on guidelines from the National Electrical Code: loads up to 16 Amps may utilize 12 gauge wire with a 20-Amp breaker, and loads up to 12 Amps - 14 gauge wire with a 15-Amp breaker. Local code and/or other factors may change these guidelines.
No, floor heating thermostats are not compatible with the towel warmers. We would also not recommend using both devices on the same control, as it does not take the same amount of time to reach the ideal temperature for each product, which could lead to one unit to overheat and the other to not function properly.