Snow Melt PowerMat 120V, 3 x 15 ft., 45 sq.ft., 18.75A
Features
-
Maximum Heat Output: Approximately 50-watts per sq. ft with 3″ cable spacing for fastest snow melting
-
Best for Heavy Snowfall: Recommended for regions with 60+ inches of annual snowfall or when rapid melting is critical
-
Even Heating: Pre-attached heating elements in a serpentine pattern with consistent 3″ spacing ensures uniform coverage
-
Fast and Easy Installation: Cut-and-turn design makes installation faster than cables while providing maximum heat density
-
Installation Support: Free SmartPlan™ installation plans, 24/7 phone support, and a 10-year limited warranty
Notices
Quebec Repairability Notice
Avis important pour les consommateurs du Québec:
WarmlyYours n’offre pas de services de réparation pour ce produit. Les seules pièces de rechange disponibles sont les kits de raccordement (splice kits) pour les câbles et les tapis de déglaçage ; aucune pièce de rechange n’est offerte pour les contrôleurs (snow melting controls). Si votre système de déglaçage (câbles, tapis ou contrôleurs) tombe en panne pendant la période de garantie, nous remplacerons l’unité complète conformément à notre politique de garantie. Notre équipe d’assistance technique est disponible 24h/24 et 7j/7 par téléphone pour toute aide à l’installation ou au dépannage. Pour plus de détails, consultez notre politique de retour. Cet avis est fourni conformément à la Loi sur la protection du consommateur du Québec, article 39 (telle qu’amendée en 2025).
Important Notice for Québec Consumers:
WarmlyYours does not provide repair services for this product. The only replacement parts available are splice kits for snow melting cables and mats; no spare parts are available for snow melting controls. If your snow melting system (cables, mats, or controls) fails within the warranty period, we will replace the entire unit according to our warranty policy. Our technical support team is available 24/7 by phone for installation and troubleshooting assistance. For full details, see our Return Policy. This notice is provided in accordance with Québec’s Consumer Protection Act, section 39 (as amended in 2025).
Snow Melt PowerMat Description
Eliminate the risk of falls on snowy or icy surfaces byadding a WarmlyYours snow melting system to your home or business. With45 ft² of radiant heat to efficiently melt snow and ice, the 3 x15 ft. 120 V snow melting mats are composed of a durable,corrosion-resistant, twin-conductor heating element affixed to a polypropylenemesh backing for even distribution of heat in asphalt, concrete or mortar underneathpaver applications.
Safe,CSA certified, for outdoor use in the U.S. and Canada, WarmlyYourssnow melting mats generate 50 watts per square foot for optimal snow meltingperformance.A 20-foot (6m) coldlead is included to adapt to your installation requirements.
Learn more about snow melting systems. Perfect for heated driveways, patios, walkways and paths, accessibility ramps, or even stairs.
Specifications
Electrical
| Amps | 18.75 A |
| Ohms | 6.4 Ω |
| Voltage | 120 V |
| Watts | 2250 W |
| Watts Per Sq. Ft. | 50 |
Warranty / Certifications
| Approvals | cCSAus Listed |
| Warranty | 10 years |
Performance
| BTU Per Hour | 7677 Btu |
| Heated Coverage | 48.75 ft² |
Product Dimensions
| Cold Lead Length | 20′ |
| Coverage | 45 ft² |
| Depth | 15′ |
| Heating Element Spacing | 3″ |
| Heating Element Thickness | 5/16″ |
| Height | 5/16″ |
| Length | 15′ |
| Size | 3′ x 15′ |
| Size and Power | 3x15 ft - 50 W/sq.ft. |
| Weight | 12 lbs |
| Width | 3′ |
Appearance
| Color | Green |
Identifiers
| Product Line Name | PowerMat |
| SKU | WHMA-120-0315 |
| UPC (GTIN-12) | 881308020576 |
Installation
| Surface Types | Asphalt, concrete or in mortar under pavers |
Logistics
| UNSPSC Code | 40101842 |
Installation Plans
This is a real example of an installation plan that uses this product. If you want to design your own room or have any questions, please contact us.
Concrete (new) Subfloor
N/A Voltage
240V Operating Cost
343 cents per hour
This Installation Plan Includes:
Documents
Installation
- Snow Melting Installation Manual (English)
- Manual de Instalación para Sistemas de Derretimiento de Nieve (Spanish)
- Retrofit Snow Melting System Application Guide (English)
- Snow Melting & Slab Heating Application Cross Sections (Spanish)
- Snow Melting & Slab Heating Application Cross Sections (French)
- Snow Melting Application Cross Sections (English)
- Snow Melting Installation Manual (French)
Project Planners
- Asphalt Snow Melt Planning Worksheet (English)
- Snow Melting Project Planning Guide Form (English)
- Snow Melting Request Quotation Form (English)
- WarmlyYours Snow Melting Field Pocket Guide - Quick Field Troubleshooting Checklist (English)
Warranties
Sell Sheets
- Outdoor Display Program Sell Sheet for Canada (English)
- Snow Melt Controller Comparison Sheet (French)
- Snow Melting Mat Sell Sheet CAD (English)
Catalogs
Frequently Asked Questions
Showing all 5 questions
Power requirements are measured in Amps and based on three factors: the watts per sq. ft. of the snow melting cable or mat, the area powered and the voltage used for the application. Our PowerMat product is rated at approximately 50 watts per sq. ft. (with 3" cable spacing), so that is a constant factor. Most snowmelt projects are powered with 240V AC – not all, but most. The one factor that is always variable is the area to be heated/powered. That is based on your project. For a point of reference, let's use the example of a 350 sq. ft. concrete patio.
The formula is (50 W/sq. ft. x area of 350 sq. ft.) / V (240V) = Amps, so 17,500 / 240V = 72.9 Amps
That depends on a number of variables (like the temperature outside) but generally speaking these snow melting systems are designed to melt 1" - 3" of snow per hour. Anything above 3" per hour is typically considered blizzard conditions.
Never cut the heating cable. A heating cable will not work if it has been cut. If the heating cable is too long, call WarmlyYours to consult with a technician who will guide you in utilizing the additional length of cable.
When installing outdoor WarmlyYours snow melting cables for your driveway, patio, walkway, terrace, stairs, ramp, etc. - NEVER cross, overlap, or allow the heating cables to touch each other. Doing so will quickly cause a circuit failure due to excessive heat build up. Always follow the installation instructions and/or design layout plan to ensure the cable is installed with the correct spacing required for proper operation.
Our systems can handle low temperatures, but many controls come equipped with a Low-Temperature Lockout Feature. This feature prevents the system from running in very low temperatures. At very low temperatures it can become difficult for the system to effectively melt the snow. It is however possible to turn off this feature should you need the system to keep running during such low temperatures.