ZoneBraker Touchscreen Multi-Zone Snow and Ice Melting Controller

ZoneBraker Touchscreen Multi-Zone Snow and Ice Melting Controller

Part Number: SC-MZ-TOUCH
This support page provides publications, manuals, videos, support articles, and common support questions

Support Questions

Showing 10 of 26 questions

GFEP is the National Electric Code (NEC) required protection for fixed outdoor deicing and snow-melting equipment, which may be accomplished by using circuit breakers equipped with ground-fault equipment protection (GFEP) of 30 mA. It is important to understand that this required equipment protection is NOT the same as a 5 mA GFCI used for personal protection.

11 people found this helpful Was this helpful? Yes No

When the design requirement's amp draw exceeds the selected controller's capacity.

5 people found this helpful Was this helpful? Yes No

Each zone may be activated for any length of time. No two applications are the same. You can start with 10 minutes and adjust up to 59 minutes per zone, and through trial and error, find the optimum zone durations for the best operation of your system.

5 people found this helpful Was this helpful? Yes No

The most common spacing for snow melting systems is 3“ from wire to wire. However, we can design snow melting systems based on your local climate and weather expectations that might have different cable spacings to ensure the most efficient system possible. We also offer snow melting mats with 3" and 4" spacing.

3 people found this helpful Was this helpful? Yes No

In an area free of obstruction and able to detect rain or snow, yet low enough so that it is easily accessible if service is needed. Atop a fence post or on an 'L' bracket on the side of a building are common.

3 people found this helpful Was this helpful? Yes No

Pavement Snow and Ice Sensor Kit (SIT–6E Sensor + Housing) and Snow Melt Aerial Sensor (AIR-SS-2).

3 people found this helpful Was this helpful? Yes No

The system may be shut off by pressing the OFF/CONFIG tab on the screen.

2 people found this helpful Was this helpful? Yes No

Yes. When more than one sensor is used, any positive activation by either of the sensors will activate the controller.

For example, the AIR-SS-2 aerial sensor and the SC-SS-PAV-6E-KIT slab sensor can be connected simultaneously for increased reliability.

2 people found this helpful Was this helpful? Yes No

If the “SNOW SENSOR OVERRIDE” button is pressed, the system will run for the set amount of time which was programmed in to the user defined “AFTER RUN” field.  To cancel the “SNOW SENSOR OVERRIDE” you must turn the system “OFF”.

Page 4 of https://www.warmlyyours.com/en-US/publications/ZONEBRAKER-TOUCHSCREEN-MULTI-ZONE-SNOW-MELTING-CONTROLLER-MANUAL-A.pdf

2 people found this helpful Was this helpful? Yes No

This control is capable of controlling up to 4 separate zones.

2 people found this helpful Was this helpful? Yes No

The electrician must route the cold lead(s) through rigid metal conduit(s) or other approved means, to get back to an accessible weatherproof junction box(s). Care must be taken by the electrician so that none of the heated section of Cable enters the conduit(s).

2 people found this helpful Was this helpful? Yes No

It depends on how the system is intended to operate. If the expectation is manual operation (ex. WiFi or Timer Control), then no sensors are required. If the expectation is automatic operation, then the system will require at least one snow sensor.

2 people found this helpful Was this helpful? Yes No

Minimum is 1.5“ and Maximum is 2.5“

2 people found this helpful Was this helpful? Yes No

No, you may vary the times for each zone as necessary.

2 people found this helpful Was this helpful? Yes No

Ground fault equipment protection (GFEP) is intended to provide protection for equipment against damaging line-to-ground currents by disconnecting all ungrounded conductors of the faulted circuit.

2 people found this helpful Was this helpful? Yes No

No, a sensor is not required with the snow melt system. However, certain automatic controllers require a temperature/moisture sensor to sense atmospheric conditions and may also require an in-slab, high temperature limit sensor to be installed (notably, asphalt installations).

1 person found this helpful Was this helpful? Yes No

The "Max Slab Temp" sensor value should be set to 50 degrees F, and adjusted as necessary to optimize operation.

1 person found this helpful Was this helpful? Yes No

This control does not incorporate a built in GFEP protection. GFEP protection must be supplied by GFEP breakers.

1 person found this helpful Was this helpful? Yes No

No, the RCO can only be used with the SCA-DUAL or the SCP-120 snow-melting controllers.

1 person found this helpful Was this helpful? Yes No

No. multiple sensors can be used, but when they activate, the entire installation activates and the control will start controlling the entire installation (all zones attached to the control).

1 person found this helpful Was this helpful? Yes No

Ensure that all the zones have a time value set for run-time operation. If a time value is not set for a particular zone, it will not activate.

1 person found this helpful Was this helpful? Yes No

A 2 pole single-phase 240V circuit works by continuously monitoring the current flowing through both hot wires of the circuit. If it detects even a slight imbalance between the current on each hot wire (indicating a ground fault), it will quickly trip, cutting off power to the circuit. Essentially, it compares each leg of the 240V circuit and trips if they are not precisely equal.

1 person found this helpful Was this helpful? Yes No

This feature prevents the snow melting system from running, by default, in temperatures below 17°F (–8.33°C), or as set by the user. At temperatures this low, it becomes difficult for the system to effectively melt the snow. It is, however, possible to turn off this feature should the system be required to keep running during these low temperatures.

1 person found this helpful Was this helpful? Yes No

Priority leaves off where it last ended. So if the controller shuts off in PRI3, that's where it will start again when the snow continues, or it is manually triggered. It will pick up exactly where it left off. Same zone. Same remaining time and after run time.

1 person found this helpful Was this helpful? Yes No

The best home features for cold climates include a simple gable roof to shed snow, covered entrances for protection, airtight triple-pane windows to prevent heat loss, and radiant heating systems. These features work together to maintain interior warmth, reduce energy bills by up to 25%, and ensure structural safety during harsh winters.

Was this helpful? Yes No

The AIR-SS-2 can be mounted at a distance up to 500 feet away from the controller using 22-gauge wires and up to 1000 feet using 18-gauge wires.

Was this helpful? Yes No





Speak to a radiant heating expert


Can’t find what you’re looking for? Create a Support Request