Splice Repair Kit Twin Conductor

Repair/Splice Kit (Twin Conductor)


Part Number: SP-TWIN
This support page provides publications, manuals, videos, and common support questions

Common Support Questions


Yes. Unlike the heating cable for electric floor heating, the cold lead wires can be trimmed.

18 people found this helpful.  Did you find this helpful? Yes No

One thermostat can control multiple heating mats/cables as long as all the heating elements are using less than 15 amps:

TempZone™ will cover aprx. 120 sq. ft. for 120V systems and 240 sq. ft. for 240V systems on one thermostat.

Environ™ will cover aprx. 150 sq. ft. for 120V systems and 300 sq. ft. for 240V systems on one thermostat.

Slab Heat will cover aprx. 90 sq. ft. for 120V systems and 180 sq. ft. for 240V systems on one thermostat.

5 people found this helpful.  Did you find this helpful? Yes No

Reflective insulation is not effective with conductive heating, which is how embedded floor heating and snow-melting systems transfer heat. To be effective, the reflective insulation surface needs to face an air space (air gap), which allows the reflected heat to be redirected.

An effective solution considers the insulating material's R-Value. This is the rating of a material's insulating properties. The "R" stands for "resistance" and refers to the material's resistance to heat flow, or temperature conduction.

1 person found this helpful.  Did you find this helpful? Yes No