Power Module w/GFCI 120V (CT230-120GA)

Power Module w/GFCI 120V (CT230-120GA)

Part Number: CT230-120GAPast Model
This support page provides publications, manuals, specifications, videos, support articles, and common support questions

Support Questions

Showing 10 of 22 questions

When the ground fault protection mechanism trips, the TEST light is On (red). To reset the ground fault protection, switch the thermostat to Off and back to On. The TEST light will turn off.

3 people found this helpful Was this helpful? Yes No

In theory, it is possible, if no other options are available. We do not recommend it, but If the thermostat is controlling the floor temperature with a floor sensor, then it can go on an exterior wall. It is important that the floor sensor gets located in an area of the floor not hit by sunshine.

If the thermostat will be controlling the air temperature with the built-in ambient sensor, then it should go on an interior wall.

3 people found this helpful Was this helpful? Yes No

A GFCI/GFEP (Ground Fault Circuit Interrupter / Ground Fault Equipment Protection) works differently than a circuit breaker by specifically detecting a small imbalance in electrical current between the hot and neutral wires, which indicates a potential ground fault (like a person touching a live wire), and instantly shutting off the power to prevent shock, while a circuit breaker only trips when there's a significant overload in current flow on the circuit, like a short circuit or too many appliances plugged in.

3 people found this helpful Was this helpful? Yes No

Relays can fail due to excessive current or voltage. When a relay is exposed to too much current, the contacts can burn out. High voltage can also damage the coil. Other reasons include mechanical wear and tear, dust or dirt buildup, and moisture. These factors can cause the relay to malfunction or stop working entirely. Regular maintenance and using the relay within its specified limits can help prevent failures.

2 people found this helpful Was this helpful? Yes No

The manufacturer reversed the wiring pattern between the LOAD side and the LINE side on newly minted controllers, verify that your wiring matches the new wiring schematic stamped on the backplate of the new controller.

1 person found this helpful Was this helpful? Yes No

No, a circuit breaker will NOT protect against a power surge; a circuit breakers primary function is to protect against excessive current flow (overload), while a surge protector is specifically designed to handle voltage spikes, which are what power surges are considered to be.

1 person found this helpful Was this helpful? Yes No

No. The Honeywell CT230 must be controlled by a Honeywell Master Thermostat.

Was this helpful? Yes No

Yes. The floor never free-runs — the thermostat’s floor sensor governs output, and you set a maximum floor temperature limit in the thermostat itself. Most heated tile bathroom floors are set between 80°F and 85°F. Set that limit during commissioning and record it on the handoff sheet so the homeowner does not raise it past the flooring manufacturer’s rated maximum.

Was this helpful? Yes No

Yes, but the tear-out is the real risk. Scan the floor with thermal imaging before demo to map the existing hydronic tubing, and never fasten or drill into it. Keep the two systems on fully independent controls so they cannot fight each other, and do not place the electric floor sensor directly above a hydronic loop — the false-high reading will short-cycle the electric system. Call PRO technical support at 800-875-5285 to review the assembly before ordering.

Was this helpful? Yes No

No. Electric floor heating cable is listed for installation under floor coverings only, and NEC 424.38(A) does not permit heating cable to be installed in walls. Running it vertically voids both the UL listing and the warranty. For warm towels and a little extra room heat, specify a heated towel rack, which is designed and listed for wall mounting.

Was this helpful? Yes No

No separate GFCI breaker is required — every WarmlyYours thermostat has a built-in Class A (5mA) GFCI. Stacking a GFCI breaker on top of it is one of the most common causes of nuisance tripping. Run a dedicated breaker sized to the load at 80% continuous duty: a 15A circuit carries up to 1,440W at 120V, a 20A circuit up to 1,920W. Loads beyond the thermostat’s 15A rating need a power module or relay.

Was this helpful? Yes No

The Master Thermostat must operate on 12 VDC and is powered by one of the linked CT230 units.

Was this helpful? Yes No

Up to ten (10) CT230 linked units can be used in a given system.

Was this helpful? Yes No

Three (3) wires; Ground, Drive, and 12 Volt DC.

Was this helpful? Yes No

Two (2) wires; just the ground and the drive wires.

Was this helpful? Yes No

Verify that the master thermostat is calling for heat. If it is and the light does not illuminate, this means that the test has failed. Cut power to the heating system at the main electrical panel, have a qualified electrician verify the installation and, if necessary, replace the CT230.

Was this helpful? Yes No

No. The nJoin power module is not compatible with a Honeywell system.

Was this helpful? Yes No

To reset the ground fault protection, switch the CT230 OFF and back ON, or cycle the circuit breaker off and on. The TEST light will turn off if the ground fault protection is functioning properly. If the TEST light comes back on, contact WarmlyYours at 1-800-875-5285 and speak to a technical support representative to help further troubleshoot your system.

Was this helpful? Yes No

The best home features for cold climates include a simple gable roof to shed snow, covered entrances for protection, airtight triple-pane windows to prevent heat loss, and radiant heating systems. These features work together to maintain interior warmth, reduce energy bills by up to 25%, and ensure structural safety during harsh winters.

Was this helpful? Yes No

The wire distance between the master thermostat and each CT230 unit must not exceed 500 ft. (150 m). 20-AWG wires are recommended.

Was this helpful? Yes No

The Master Thermostat.

Was this helpful? Yes No

GFCI can fail for various reasons, such as wear and tear, moisture, corrosion, power surges, faulty wiring, or improper installation. Some of these causes can be prevented by regular inspection and maintenance, while others may require professional assistance. It is important to note that GFCI devices (ex. thermostat, breakers, outlets) should be tested regularly as these do wear out over time.

Was this helpful? Yes No


Specifications

Electrical

Amps 15 A
Connection 4 wires, double pole
Connection Method Hardwired
Ground Fault Protection (GFCI) Class A, 5 mA
Maximum Load (Resistive Only) 1800 W - 120 V, 15 A / 3600 W - 240 V, 15 A
Voltage 120 V
Watts 1440 W

Product Dimensions

Length 4″
Weight 1 lbs
Width 3″

Identifiers

SKU CT230-120GA

Warranty / Certifications

Warranty Limited 3-year warranty and lifetime technical support