Thermostat EasyStat™ Non Programmable 120V with GFCI 5mA
This support page provides publications, manuals, specifications, videos, support articles, and common support questions
Support Questions
Showing 10 of 21 questions
The breaker and wire sizes are selected based on the total amperage of the WarmlyYours heating system connected to a single thermostat. This information is on the WarmlyYours heating system's installation plan, electrical plan, or UL label. Based on guidelines from the National Electrical Code: loads up to 16 Amps may utilize 12 gauge wire with a 20-Amp breaker, and loads up to 12 Amps - 14 gauge wire with a 15-Amp breaker. Local code and/or other factors may change these guidelines.
In theory, it is possible, if no other options are available. We do not recommend it, but If the thermostat is controlling the floor temperature with a floor sensor, then it can go on an exterior wall. It is important that the floor sensor gets located in an area of the floor not hit by sunshine.
If the thermostat will be controlling the air temperature with the built-in ambient sensor, then it should go on an interior wall.
A GFCI/GFEP (Ground Fault Circuit Interrupter / Ground Fault Equipment Protection) works differently than a circuit breaker by specifically detecting a small imbalance in electrical current between the hot and neutral wires, which indicates a potential ground fault (like a person touching a live wire), and instantly shutting off the power to prevent shock, while a circuit breaker only trips when there's a significant overload in current flow on the circuit, like a short circuit or too many appliances plugged in.
Relays can fail due to excessive current or voltage. When a relay is exposed to too much current, the contacts can burn out. High voltage can also damage the coil. Other reasons include mechanical wear and tear, dust or dirt buildup, and moisture. These factors can cause the relay to malfunction or stop working entirely. Regular maintenance and using the relay within its specified limits can help prevent failures.
If your thermostat is blank, the first thing to do is to test to see if voltage is present at the rear of the thermostat. If no power is reaching the thermostat, please inspect the circuit breaker powering the thermostat in the breaker panel, and verify that the breaker is a non-GFCI type. If it is a GFCI breaker, replace it with a non-GFCI breaker. If there is power entering the thermostat and it is blank, it will need to be replaced.
No, a circuit breaker will NOT protect against a power surge; a circuit breakers primary function is to protect against excessive current flow (overload), while a surge protector is specifically designed to handle voltage spikes, which are what power surges are considered to be.
The flashing digits indicate that the actual (measured) floor temperature exceeds the thermostat temperature limit.
The temperature limit is set for either tile (104°F/40°C) or laminate (82°F/28°C) when the thermostat is first set up or re-configured.
For example: When the floor type (protection) is set to laminate, the limit defaults to 82°F/28°C. If the floor temperature goes above this - whether due to radiant floor heating or external heating sources, then the digits will flash and the heating is switched off.
Turning the temperature up or down will not affect the flashing digits. And leaving the thermostat alone with flashing digits does not harm the system.
Tip: To turn off the heated floor (ex. for months when it is not needed), on the outer edge of the thermostat, depress the lower right side button for 3-5 seconds. This will also turn it back on.
Yes. The floor never free-runs — the thermostat’s floor sensor governs output, and you set a maximum floor temperature limit in the thermostat itself. Most heated tile bathroom floors are set between 80°F and 85°F. Set that limit during commissioning and record it on the handoff sheet so the homeowner does not raise it past the flooring manufacturer’s rated maximum.
Yes, but the tear-out is the real risk. Scan the floor with thermal imaging before demo to map the existing hydronic tubing, and never fasten or drill into it. Keep the two systems on fully independent controls so they cannot fight each other, and do not place the electric floor sensor directly above a hydronic loop — the false-high reading will short-cycle the electric system. Call PRO technical support at 800-875-5285 to review the assembly before ordering.
No. Electric floor heating cable is listed for installation under floor coverings only, and NEC 424.38(A) does not permit heating cable to be installed in walls. Running it vertically voids both the UL listing and the warranty. For warm towels and a little extra room heat, specify a heated towel rack, which is designed and listed for wall mounting.
No separate GFCI breaker is required — every WarmlyYours thermostat has a built-in Class A (5mA) GFCI. Stacking a GFCI breaker on top of it is one of the most common causes of nuisance tripping. Run a dedicated breaker sized to the load at 80% continuous duty: a 15A circuit carries up to 1,440W at 120V, a 20A circuit up to 1,920W. Loads beyond the thermostat’s 15A rating need a power module or relay.
The best home features for cold climates include a simple gable roof to shed snow, covered entrances for protection, airtight triple-pane windows to prevent heat loss, and radiant heating systems. These features work together to maintain interior warmth, reduce energy bills by up to 25%, and ensure structural safety during harsh winters.
WarmlyYours controllers incorporate built-in Class A GFCI protection for all new floor heating systems. Class A GFCI provides personnel protection and trips when ground fault current exceeds 5 mA (milliamps). Class B GFCI protection is pretty much obsolete, but older systems may still require it. WarmlyYours controllers with built-in Class B GFCI provide equipment and circuit protection and operates when a fault to ground exceeds 15 mA.
GFCI can fail for various reasons, such as wear and tear, moisture, corrosion, power surges, faulty wiring, or improper installation. Some of these causes can be prevented by regular inspection and maintenance, while others may require professional assistance. It is important to note that GFCI devices (ex. thermostat, breakers, outlets) should be tested regularly as these do wear out over time.
A floor sensor measures floor temperature so a compatible thermostat can regulate comfort and enforce the flooring manufacturer’s temperature limit. Some thermostats, including nTrust 2.0, offer a regulator mode without a sensor, but that mode does not measure floor temperature. Use sensor-based temperature control whenever required by the flooring or heating-system instructions.
Documents
Operation Manuals
Wiring Diagrams
- SmartStat™, EasyStat™, Comfort Regulator, Power Module Wiring Diagram with TempZone™ Twin Conductor or Environ™ (120V or 240V) (English)
- SmartStat TH115 to TempZone Flex Wiring Diagram (English)
- SmartStat™, EasyStat™ Wiring Diagram with Multiple Environ™ using a Junction Box (English)
- SmartStat™, EasyStat™, Comfort Regulator, Power Module Wiring Diagram with Environ™ 120V or 240V Flat Lead (English)
- TempZone™ Custom & Standard Mat Wiring Diagram (English)
- WIRING DIAGRAM 120V & 240V Heating Products with PB112D-GA (English)
- Wiring Diagram for TempZone™ Cut & Turn Single Conductor (Multiple rolls) 120V & 240V with SmartStat™, EasyStat™ and Comfort Regulator (English)
- Wiring Diagram for TempZone™ Cut & Turn Twin Conductor (Multiple Rolls) 120V & 240V with SmartStat™, EasyStat™, Comfort Regulator and Power Modules (English)
- Wiring Diagram for TempZone™ Cut & Turn Twin Conductor 120V & 240V with SmartStat™ and EasyStat™ (English)
- Wiring Diagram for TempZone™ Cut & Turn Twin Conductor 120V & 240V with SmartStat™, EasyStat™ and Comfort Regulator (English)
Sell Sheets
Technical Information
Installation
Specifications
Electrical
| Connection | Single pole, 2 wires, hot & neutral |
| Connection Method | Hardwired |
| Maximum Load (Resistive Only) | 1800 W - 120 V, 15 A |
| Supply | 120 VAC, 50/60Hz |
| Voltage | 120 V |
Product Dimensions
| Depth | 2″ |
| Installed Depth | 0.75″ |
| Length | 4″ |
| Weight | 1 lbs |
| Width | 3″ |
Identifiers
| Ground Fault Protection (GFCI) | Class A, 5 mA |
| SKU | TH114-AF-120GA |
| UPC (GTIN-12) | 881308020637 |
Thermostat
| Has Floor Sensor | y |