Contact Us After Hours

Loading...

Loading contact options...

Sign In

Loading...

Loading...



TempZone™ Floor Heating Cable (Twin) 120V, (3W/ft.), 468 ft., 11.7A




Get an Instant Quote
Support Page

Features

  • 25 Year Warranty

  • Ul listed and Gfci protected

  • Loose cable offers the freedom and flexibility to fit any room shape

TempZone™ Cable with Strips Description

WarmlyYoursTempZone™ Floor Heating Cable (Twin) brings radiant warmth and comfort to anyroom. This free-form cable provides the ultimate in flexibility, makinginstallation ideal for rooms of unusual size and shape. The TempZone™ FloorHeating Cable (Twin) also provides an alternative for installers who prefer theflexibility and freedom of working with loose cable. Just 1/8 inch thick, the TempZone™ Floor Heating Cable (Twin) features a twin conductorthat is ultra-low EMF by design and includes 15’ cold lead. The 120 V 468 ft. heating cable provides3 watts/lineal foot andcan be installed at 3” or 4” intervals depending on the needs of yourinstallation. 

Specifications

Electrical

Amps 11.7 A
Cold Lead Wire Gauge 14 AWG
Floor Load 1.4 kW
Ohms 10.2564 Ω
Ohms Per Ft 0.022 Ohm/ft
Thermal Power 1.4 kW
Voltage 120 V
Watts 1404 W

Warranty / Certifications

Approvals cULus listed
Warranty 25 Year Warranty
Wet Location Listed US, Canada

Performance

BTU Per Hour 4791 Btu

Product Dimensions

Cable Thickness ⅛″
Cold Lead Length 15′
Coverage 117 ft²
Heating Cable Length 468′
Length 468′
Weight 8.5 lbs

Installation

Fixing Strips at 3 inch spacing 100
Fixing Strips at 4 inch spacing 120
Fixing Strips at 5 inch spacing 160
Floor Types At 3 inch spacing: tile, stone, laminate, and carpet*. At 4 inch spacing: hardwood, engineered wood, laminate, carpet*. * Note: carpet installations approved in US only when embedded in self-leveling underlayment

Cabling Specs

Ideal Cable Spacing 3″

Logistics

Package Contents (1) TempZone Floor Heating Cable Twin 120V 3W/ft 468 ft 11.7A (TCT120-3W-468); 1x Floor Heating Sensor (FH-BACKUP-SENSOR)
UNSPSC Code 40101830

Identifiers

SKU TCT120-3W-468
UPC (GTIN-12) 881308031237

Frequently Asked Questions

Showing all 5 questions

While WarmlyYours electric radiant floor heating systems are typically installed by your floor covering contractor, a licensed electrician is recommended for the final thermostat hook-up. With every quote, we provide an Installation Plan layout, together with an electrical plan that has all the info required for the electrician.

41 people found this helpful Was this helpful? Yes No

Our electric radiant floor heating systems have withstood rigorous safety testing and earned the UL listing. They produce much less EMF than common household appliances like your TV or vacuum cleaner. The EPRI (Electric Power Research Institute) tests all electrical devices and publishes the data. Many common household appliances are tested at a distance of 6 inches. The test results indicate that on average, the EMF emitted for the following appliances, measured in Milligauss (mG) units, is:

Vacuum Cleaner: 300 mG

Microwave: 200 mG

Portable Heater: 100 mG

Dishwasher: 20 mG

Washing Machine: 20 mG

WarmlyYours TempZone™ (Twin): 1.8 mG

32 people found this helpful Was this helpful? Yes No

The floor heating systems are offered in both 120 volt and 240 volt for the North American market. A 208 volt breaker panel can also accommodate our 240 volt floor heating system. It is important to note that the energy consumption will be the same: a 240 volt system will not cost more to operate than a 120 volt system. You are billed in kilowatts, and the 120 volt and 240 volt systems use the same amount of kilowatts. WarmlyYours often specifies a 120 volt system in smaller projects while a 240 volt system is typically recommended for larger projects (120 square feet of electric floor heating coverage or more). The benefit of switching to a 240 volt system is the reduction in amperage. Our programmable thermostat can control a radiant floor system up to 15 amps. The 120 volt system will reach 15 amps at 120 square feet of electric floor heating coverage. However, the 240 volt system will reach 15 amps at 240 square feet of electric floor heating coverage, allowing a much larger system to be connected to the thermostat. For installations over 240 square feet, a relay contactor or power modules are needed.

26 people found this helpful Was this helpful? Yes No

WarmlyYours’ TempZone™ product is most commonly installed under tile, stone, and marble flooring, but can also be installed under many other popular floor covering options such as hardwood, vinyl and linoleum. We also have our Environ system, which is an electric floor heating product as well and is specially designed for installation under carpet (in the U.S. only), laminate and floating wood. WarmlyYours can accommodate any flooring type with either of the electric radiant floor heating products that we offer. If your flooring type isn't listed here, just give us a call at (800) 875-5285 and we will be happy to discuss it with you.

29 people found this helpful Was this helpful? Yes No

Yes. Unlike the heating cable for electric floor heating, the cold lead wires can be trimmed.

22 people found this helpful Was this helpful? Yes No