Prodeso Preformed Outside Corner 6″ x 6″ for Membrane (Each)
Part Number: TC-MEM-BL-CNR-OUT This support page provides publications, manuals, specifications, videos, support articles, and common support questions
Waterproofing for the room is in the layer above the floor heating system. The layers for waterproofing this type of floor are:
subfloor
thinset
uncoupling membrane
tempzone heating cable
waterproofing tape for seams and corners
thinset or self leveling cement
tile floor
5 people found this helpful
Was this helpful?
Self-Leveling (SLC) Cement is not recommended for use over Prodeso. Contact WarmlyYours if self-leveling underlayment is required.
2 people found this helpful
Was this helpful?
Install membrane over entire floor first, then heating cable, then do the tiles 1 or 2 at a time. Never cover the Prodeso entirely with thin-set first. Only apply as much thin-set as needed to lay a couple of tiles at a time.
2 people found this helpful
Was this helpful?
Waterproofing is recommended under and around tubs/showers. It’s also recommended wherever the tile could possibly be exposed to considerable amounts of water. Prodeso is naturally waterproof, but the corners and seams need to be treated with waterproofing tape and thin-set. (Use Pro WP Waterproofing Band 5“ - Soft polyethylene tape – to seal seams.)
2 people found this helpful
Was this helpful?
Prodeso installation membrane does not eliminate the need for expansion joints (adhere to local codes).
1 person found this helpful
Was this helpful?
Unroll the membrane the day before installation to flatten it and avoid any potential ‘memory’ due to environmental conditions.
1 person found this helpful
Was this helpful?
1.25"
1 person found this helpful
Was this helpful?
The wire spacing in the Prodeso Cable Installation Membrane is 3.75“, or every 3rd peg.
1 person found this helpful
Was this helpful?
Yes, we offer several options to help make your floor heating system water resistant or waterproof. Our TempZone product line is designed for wet areas - making it completely safe for rooms that will have water on the floor at times or may experience leaks or flooding. We also offer waterproofing bands for our TempZone Cable + Prodeso Uncoupling Membrane system. Allowing you to waterproof all seams and the perimeters of the wall - guaranteeing that your floor heating system stays safe and prevents water from leaking to areas below.
Was this helpful?
Not a good choice for mosaic tile work, Prodeso requires 2“ x 2“ or larger tiles.
Was this helpful?
Yes, but the tear-out is the real risk. Scan the floor with thermal imaging before demo to map the existing hydronic tubing, and never fasten or drill into it. Keep the two systems on fully independent controls so they cannot fight each other, and do not place the electric floor sensor directly above a hydronic loop — the false-high reading will short-cycle the electric system. Call PRO technical support at 800-875-5285 to review the assembly before ordering.
Was this helpful?
When laying Prodeso installation membranes adjacent to each other, align the square relief pegs for the later heating element cable runs.
Questions about heated floors, sizing or an order? Ask away — a real person will answer.