TempZone Flex Roll Kit 1.5 x 4 ft (6 sqft) with nTrust 2.0 Touch Nonprogrammable Thermostat, 120V, 0.75A
TempZone Flex Roll Kits with nTrust 2.0 LED Touch Thermostat Description
Specifications
Electrical (TRT120-1.5x04)
| Amps | 0.75 A |
| Cold Lead Wire Gauge | 17 AWG |
| Floor Load | 0.09 kW |
| Ohms | 160 Ω |
| Ohms Per Ft | 6.963 Ohm/ft |
| Thermal Power | 0.09 kW |
| Voltage | 120 V |
| Watts | 90 W |
| Watts Per Sq. Ft. | 15 Watts Per Sq. Ft. |
Warranty / Certifications (TRT120-1.5x04)
| Approvals | cULus listed |
| Warranty | 25 Year Warranty |
| Wet Location Listed | US, Canada |
Warranty / Certifications (UTN5-4999)
| Approvals | cULus listed |
| Ingress Protection (IPxx) Rating | IP20 |
| Warranty | Limited 3-year warranty and lifetime technical support |
Performance (TRT120-1.5x04)
| BTU Per Hour | 307 Btu |
Electrical (UTN5-4999)
Product Dimensions (TRT120-1.5x04)
| Cold Lead Length | 15′ |
| Coverage | 6 ft² |
| Heating Cable Length | 22.98′ |
| Heating Element Thickness | ⅛″ |
| Length | 4′ |
| Size | 1.5′ x 04′ |
| Weight | 1.8 lbs |
| Width | 1′ 6″ |
Appearance (TRT120-1.5x04)
| Color | Green |
Appearance (UTN5-4999)
| Color | White Acrylic |
| Display | LED Light Through |
Product Dimensions (UTN5-4999)
| Depth | 1.73″ |
| Installed Depth | 0.46″ |
| Length | 4.98″ |
| Weight | 0.6 lbs |
| Width | 3.09″ |
Thermostat (UTN5-4999)
| Floor Sensor Compatibility | 10k ohms or 12k ohms |
| Includes Floor Sensor | 10k ohms, 15′ lead |
| Maximum Ambient Temperature Setting | 77 °F |
| Maximum Floor Temperature Setting | 104 °F |
| Minimum Ambient Temperature Setting | 32 °F |
| Minimum Floor Temperature Setting | 41 °F |
Installation (TRT120-1.5x04)
| Floor Types | Commonly installed beneath tile and stone |
Logistics (TRT120-1.5x04)
| Package Contents | (1) TempZone Flex Roll 120V 1.5′ x 4′ 6 sq ft 0.8A (TRT120-1.5x04); 1x Floor Heating Sensor (FH-BACKUP-SENSOR) |
| UNSPSC Code | 40101830 |
Identifiers (TRT120-1.5x04)
| SKU | TRT120-1.5x04 |
| UPC (GTIN-12) | 881308021290 |
Identifiers (UTN5-4999)
| SKU | UTN5-4999 |
| UPC (GTIN-12) | 881308080426 |
Documents
Installation
- TempZone™ Flex Roll (Twin Conductor) Installation Manual (English)
- Manual de instalación de su Sistema de Calefacción Radiante Tempzone (Spanish)
- Setting Up the nTrust 2.0 UTN5-4999 (English)
- TempZone™ Flex Roll (Twin Conductor) Important Installation Information Summary (English)
- TempZone™ Flex Roll Cuts and Turns (English)
- TempZone™ Flex Roll Nailed-Down Hardwood Installation Overview (English)
- TempZone™ Floor Cross Section in Shower (English)
- nTrust 2.0 UTN5 Touch Nonprogrammable Thermostat Startup Guide (English, French)
- nTrust 2.0 UTN5 Touch Nonprogrammable Thermostat Startup Guide (English, Spanish)
Operation Manuals
- nTrust 2.0 UTN5 Touch Nonprogrammable Thermostat User Manual (English)
- nTrust 2.0 UTN5 Touch Nonprogrammable Thermostat User Manual (French)
- nTrust 2.0 UTN5 Touch Nonprogrammable Thermostat User Manual (Spanish)
Project Planners
- Floor Heating Request for Quotation Form (English)
- Calculating Project Dimensions (English)
- Floor Heating Project Planning Guide Form (English)
- Heated Tile Substrate Compatibility & Risk Map (English)
- TempZone Flex Rolls Materials And Tools Checklist (English)
Technical Information
- PRO Field Checklist: Electric Floor Heating Diagnostics & Troubleshooting (English)
- TempZone Twin Master Specification Sheet (English)
Wiring Diagrams
Warranties
Sell Sheets
- Radiant Heating Controls Comparison Chart USA (English)
- TempZone Flex Roll Sell Sheet (English)
- TempZone Floor Heating Comparison Chart USA (English)
- nTrust 2.0 UNT5 Touch Nonprogrammable Thermostat Sell Sheet USA (English)
Catalogs
Case Studies
- 5TH Avenue Condominiums - New York City, NY - TempZone™ Electric Radiant Floor Heating (English)
- Chicago Housing Authority Senior Living Apartment Building - Chicago, IL - TempZone™ Electric Radiant Floor Heating (English)
- Mandarin Oriental Hotel - Las Vegas, NV - TempZone™ Electric Radiant Floor Heating (English)
- Ocean House Hotel & Residences - Westerly, RI - TempZone™ Electric Radiant Floor Heating (English)
- Universal Design Living Laboratory - Columbus, OH - TempZone™ Electric Radiant Floor Heating (English)
Frequently Asked Questions
Showing all 5 questions
While WarmlyYours electric radiant floor heating systems are typically installed by your floor covering contractor, a licensed electrician is recommended for the final thermostat hook-up. With every quote, we provide an Installation Plan layout, together with an electrical plan that has all the info required for the electrician.
Our electric radiant floor heating systems have withstood rigorous safety testing and earned the UL listing. They produce much less EMF than common household appliances like your TV or vacuum cleaner. The EPRI (Electric Power Research Institute) tests all electrical devices and publishes the data. Many common household appliances are tested at a distance of 6 inches. The test results indicate that on average, the EMF emitted for the following appliances, measured in Milligauss (mG) units, is:
Vacuum Cleaner: 300 mG
Microwave: 200 mG
Portable Heater: 100 mG
Dishwasher: 20 mG
Washing Machine: 20 mG
WarmlyYours TempZone™ (Twin): 1.8 mG