Common Support Questions


To prevent any melting, ensure that the heating wire is at least 4” from the toilet wax ring.

15 people found this helpful.  Did you find this helpful? Yes No

Yes, but any furniture that may trap heat, such as pieces with an enclosed bottom, should be avoided. Furniture on legs with a clearance of at least 3" is permissible.

13 people found this helpful.  Did you find this helpful? Yes No

The subfloor will need to be prepared as per the instructions of the self-leveling cement (SLC) used. Please note that most self-leveling products require the use of a primer as specified by the SLC company.

9 people found this helpful.  Did you find this helpful? Yes No

One thermostat can control multiple heating mats/cables as long as all the heating elements are using less than 15 amps:

TempZone™ will cover aprx. 120 sq. ft. for 120V systems and 240 sq. ft. for 240V systems on one thermostat.

Environ™ will cover aprx. 150 sq. ft. for 120V systems and 300 sq. ft. for 240V systems on one thermostat.

Slab Heat will cover aprx. 90 sq. ft. for 120V systems and 180 sq. ft. for 240V systems on one thermostat.

5 people found this helpful.  Did you find this helpful? Yes No

No. A bathroom floor would be installed in the same way. Our TempZone floor heating systems are wet-location listed and ideal for bathroom floors.

3 people found this helpful.  Did you find this helpful? Yes No

Yes, Luxury Vinyl Tile (LVT) is typically installed over the embedded heating element using self-leveling cement (SLC). Many people choose to use SLC when installing tile over floor heating.

We do not suggest using thinset to encase the heating wires with LVT, as it is very difficult to get thinset completely flat.

3 people found this helpful.  Did you find this helpful? Yes No

We suggest the heating product be embedded in a minimum of 3/8" of self-leveling cement (SLC). Always check with the manufacturer for specific recommendations.

2 people found this helpful.  Did you find this helpful? Yes No

Yes, if the flooring manufacturer recommends this installation method. In most cases, the heating element will still need to be embedded in self-leveling cement before the flooring is installed.

1 person found this helpful.  Did you find this helpful? Yes No

There are heating systems designed for floating floors, such as our Environ system. However, the flooring must be rigid enough so it does not mold itself to the heating cables over time.

Check the flooring manufacturer's floor heating recommendations. In most cases, the heating system will need to be embedded beneath the flooring. Check for all "flatness" requirements for the flooring you choose. The flattest floors utilize self-leveling cement when installed correctly.

1 person found this helpful.  Did you find this helpful? Yes No

Self-Leveling (SLC) Cement is not recommended for use over Prodeso. Contact WarmlyYours if self-leveling underlayment is required.

1 person found this helpful.  Did you find this helpful? Yes No

Install membrane over entire floor first, then heating cable, then do the tiles 1 or 2 at a time. Never cover the Prodeso entirely with thin-set first. Only apply as much thin-set as needed to lay a couple of tiles at a time.

1 person found this helpful.  Did you find this helpful? Yes No

Waterproofing is recommended under and around tubs/showers. It’s also recommended wherever the tile could possibly be exposed to considerable amounts of water. Prodeso is naturally waterproof, but the corners and seams need to be treated with waterproofing tape and thin-set. (Use Pro WP Waterproofing Band 5“ - Soft polyethylene tape – to seal seams.)

1 person found this helpful.  Did you find this helpful? Yes No

Reflective insulation is not effective with conductive heating, which is how embedded floor heating and snow-melting systems transfer heat. To be effective, the reflective insulation surface needs to face an air space (air gap), which allows the reflected heat to be redirected.

An effective solution considers the insulating material's R-Value. This is the rating of a material's insulating properties. The "R" stands for "resistance" and refers to the material's resistance to heat flow, or temperature conduction.

1 person found this helpful.  Did you find this helpful? Yes No

Not a good choice for mosaic tile work, Prodeso requires 2“ x 2“ or larger tiles.

Did you find this helpful? Yes No

Prodeso installation membrane does not eliminate the need for expansion joints (adhere to local codes).

Did you find this helpful? Yes No

Unroll the membrane the day before installation to flatten it and avoid any potential ‘memory’ due to environmental conditions.

Did you find this helpful? Yes No

When laying Prodeso installation membranes adjacent to each other, align the square relief pegs for the later heating element cable runs.

Did you find this helpful? Yes No

1.25"

Did you find this helpful? Yes No

The wire spacing in the Prodeso Cable Installation Membrane is 3.75“, or every 3rd peg.

Did you find this helpful? Yes No

Publications and Manuals



Specifications


Identifiers

SKU TC-MEM-BL-CNR-OUT
UPC (GTIN-12) 881308051051

Warranty / Certifications

Warranty 10 years

Product Dimensions

Weight 0.04 lbs

Videos



Similar Items




Speak to a radiant heating expert


Can’t find what you’re looking for? Create a Support Request