Wire, heating, ruler, .028 OPF, 120V 375, 240V 749
How Much Cable Will I Need?
| Coverage (sq. ft.) Based on Cable Spacing | ||||||
|---|---|---|---|---|---|---|
| Length | Voltage | 3" | 3.5" | 3.75" | 4" | 5" |
| 30′ | 120 | 7.5 | 8.8 | 9.4 | 10 | 12.5 |
| 40′ | 120 | 10 | 11.7 | 12.5 | 13.3 | 16.7 |
| 50′ | 120 | 12.5 | 14.6 | 15.6 | 16.7 | 20.8 |
| 55′ | 240 | 13.8 | 16 | 17.2 | 18.3 | 22.9 |
| 65′ | 240 | 16.3 | 19 | 20.3 | 21.7 | 27.1 |
| 70′ | 120 | 17.5 | 20.4 | 21.9 | 23.3 | 29.2 |
| 75′ | 240 | 18.8 | 21.9 | 23.4 | 25 | 31.3 |
| 90′ | 120 | 22.5 | 26.3 | 28.1 | 30 | 37.5 |
| 95′ | 240 | 23.8 | 27.7 | 29.7 | 31.7 | 39.6 |
| 115′ | 240 | 28.8 | 33.5 | 35.9 | 38.3 | 47.9 |
| 120′ | 120 | 30 | 35 | 37.5 | 40 | 50 |
| 150′ | 120 | 37.5 | 43.8 | 46.9 | 50 | 62.5 |
| 155′ | 240 | 38.8 | 45.2 | 48.4 | 51.7 | 64.6 |
| 180′ | 120 | 45 | 52.5 | 56.3 | 60 | 75 |
| 195′ | 240 | 48.8 | 56.9 | 60.9 | 65 | 81.3 |
| 220′ | 120 | 55 | 64.2 | 68.8 | 73.3 | 91.7 |
| 235′ | 240 | 58.8 | 68.5 | 73.4 | 78.3 | 97.9 |
| 260′ | 120 | 65 | 75.8 | 81.3 | 86.7 | 108.3 |
| 275′ | 240 | 68.8 | 80.2 | 85.9 | 91.7 | 114.6 |
| 300′ | 120 | 75 | 87.5 | 93.8 | 100 | 125 |
| 315′ | 240 | 78.8 | 91.9 | 98.4 | 105 | 131.3 |
| 340′ | 120 | 85 | 99.2 | 106.3 | 113.3 | 141.7 |
| 355′ | 240 | 88.8 | 103.5 | 110.9 | 118.3 | 147.9 |
| 375′ | 120 | 93.8 | 109.4 | 117.2 | 125 | 156.3 |
| 395′ | 240 | 98.8 | 115.2 | 123.4 | 131.7 | 164.6 |
| 432′ | 120 | 108 | 126 | 135 | 144 | 180 |
| 435′ | 240 | 108.8 | 126.9 | 135.9 | 145 | 181.3 |
| 515′ | 240 | 128.8 | 150.2 | 160.9 | 171.7 | 214.6 |
| 595′ | 240 | 148.8 | 173.5 | 185.9 | 198.3 | 247.9 |
| 675′ | 240 | 168.8 | 196.9 | 210.9 | 225 | 281.3 |
| 749′ | 240 | 187.3 | 218.5 | 234.1 | 249.7 | 312.1 |
| 864′ | 240 | 216 | 252 | 270 | 288 | 360 |
The amount of cable you'll need depends on the heat output and amount of heating coverage you want, both of which are impacted by the spacing of the heating cable. The spacing of the heating elements is dictated by how the cable is installed and WarmlyYours offers two different installation methods: with Fixing Strips or with our Prodeso Membrane.
Fixing Strips
An economical option, requires more work than the membrane.
Ideal spacing for installing TempZone 3.7-watt Cable:
- 3" (14.8-watts per sq. ft.)
Other spacing options:
- 4" (11.1-watts per sq. ft.)
- 5" (8.88-watts per sq. ft.)
Prodeso Membrane
Costlier than strips, speeds up installation and provides uncoupling benefits
Ideal spacing for installing TempZone 3.7-watt Cable:
- 3.75" (11.84-watts per sq. ft.)
Other spacing options:
- 5" (8.88-watts per sq. ft.)
You can use our quote tool to get a rough estimate of the amount of cable you'll need for a project.
Or contact us for help:
You can also submit a drawing of your project (with dimensions) and we'll provide you with a free installation plan with the exact amount of cable you'll need. Get started
Features
-
Built-in ruler markings for precise, repeatable spacing
-
Ideal for large areas requiring consistent coverage
-
Flexible, durable cable for clean turns and complex layouts
-
Comes with easy-to-read hash marks at every half-inch, inch, and foot increment on the cable
-
Can be used to heat some of the most popular floor coverings like tile, stone, marble, luxury vinyl tile, and more
TempZone™ Floor Heating Ruler Cable Description
Wire, heating, ruler, .028 OPF, 120V 375, 240V 749
Specifications
Electrical
Warranty / Certifications
| Approvals | cULus |
| Warranty | 25 Year Warranty |
| Wet Location Listed | US, Canada |
Product Dimensions
| Cold Lead Length | 12′ |
| Cold Lead Thickness | 0.22″ |
| Factory Splice Thickness | 0.41″ |
| Heating Element Thickness | 3/16″ |
| Weight | 0.038 lbs |
Appearance
| Color | Yellow |
Installation
| Floor Types | Tile, Marble, Stone, Vinyl, LVT, LVP |
| Ideal Cable Spacing with Fixing Strips | 4″ |
| Ideal Cable Spacing with Prodeso Membrane | 3.75″ |
Logistics
| Package Contents | (1) Wire heating ruler .028 OPF 120V 375 240V 749 (WR028); 1x Floor Heating Sensor (FH-BACKUP-SENSOR) |
| UNSPSC Code | 40101830 |
Identifiers
| SKU | WR028 |
| UPC (GTIN-12) | 881308084530 |
Installation Plans
This is a real example of an installation plan that uses this product. If you want to design your own room or have any questions, please contact us.
Tile, Marble or Stone Subfloor
Unconfirmed/Other Voltage
120V Operating Cost
13 cents per hour
This Installation Plan Includes:
Documents
Installation
Project Planners
- Floor Heating Request for Quotation Form (English)
- Calculating Project Dimensions (English)
- Floor Heating Project Planning Guide Form (English)
- Heated Tile Substrate Compatibility & Risk Map (English)
- TempZone Cable Materials And Tools Checklist (English)
Wiring Diagrams
Warranties
Sell Sheets
- TempZone Floor Heating Comparison Chart USA (English)
- TempZone Floor Heating Ruler Cable Sell Sheet USA (English)
Catalogs
Case Studies
- 5TH Avenue Condominiums - New York City, NY - TempZone™ Electric Radiant Floor Heating (English)
- Chicago Housing Authority Senior Living Apartment Building - Chicago, IL - TempZone™ Electric Radiant Floor Heating (English)
- Mandarin Oriental Hotel - Las Vegas, NV - TempZone™ Electric Radiant Floor Heating (English)
- Ocean House Hotel & Residences - Westerly, RI - TempZone™ Electric Radiant Floor Heating (English)
- Universal Design Living Laboratory - Columbus, OH - TempZone™ Electric Radiant Floor Heating (English)
Frequently Asked Questions
Showing all 5 questions
Our electric radiant floor heating systems have withstood rigorous safety testing and earned the UL listing. They produce much less EMF than common household appliances like your TV or vacuum cleaner. The EPRI (Electric Power Research Institute) tests all electrical devices and publishes the data. Many common household appliances are tested at a distance of 6 inches. The test results indicate that on average, the EMF emitted for the following appliances, measured in Milligauss (mG) units, is:
Vacuum Cleaner: 300 mG
Microwave: 200 mG
Portable Heater: 100 mG
Dishwasher: 20 mG
Washing Machine: 20 mG
WarmlyYours TempZone™ (Twin): 1.8 mG
WarmlyYours’ TempZone™ product is most commonly installed under tile, stone, and marble flooring, but can also be installed under many other popular floor covering options such as hardwood, vinyl and linoleum. We also have our Environ system, which is an electric floor heating product as well and is specially designed for installation under carpet (in the U.S. only), laminate and floating wood. WarmlyYours can accommodate any flooring type with either of the electric radiant floor heating products that we offer. If your flooring type isn't listed here, just give us a call at (800) 875-5285 and we will be happy to discuss it with you.