Snow and Ice Melting Control Premium


Snow and Ice Melting Control Premium
Support Page
Also Available on Amazon

Affiliate disclosure: As an Amazon Associate, we may earn commissions from qualifying purchases from Amazon.com

Features

  • Voltage: 120/240 VAC; 50/60 hz, 24A

  • Features NEMA 3R enclosure

  • Supports up to 6 sensors (aerial, gutter, or pavement)

  • Automatic and manual override operator controls

  • 2-year warranty

Premium Snow & Ice Melt Control Description

The SCP-120 premium, automatic snow/ice melting control provides for easy installation and operation to minimize energy use. For use with WarmlyYours snow melting or roof and gutter deicing systems, it operates electrically- and mechanically-held contactors for pilot duty applications. 

The SCP-120 Premium Snow Melt Control includes an OT-Sensor (for use as an additional slab temperature sensor) and features a NEMA 3R wall-mounted enclosure (recommended for indoor installation). With an Energy Management Computer (EMC) interface and heater hold-on and test capabilities, the unit is rated for 120/240 VAC and supports up to six sensors (aerial, gutter, or pavement). cULus Listed for use in Canada and the U.S.

The maximum load for this control is 24 Amps. We do recommend that it is used in conjunction with a compatible relay panel.

Specifications

Features

Adjust After-Run Time true
Air Temp Sensor true
Automatic true
Moisture Sensor true
Outdoor Rated true
Slab Temp Sensor true

Warranty / Certifications

Approvals cULus listed
Area of Use Non-hazardous locations
Warranty 2 years
Waterproofing NEMA 3R

Installation

Best Use Best For Asphalt Projects

Electrical

Compatible Sensors and Accessories RCO, AIR-SS, AIR-SS-2, GTR-SS, SC-SS-PAV-6E-KIT
Connection Method Hardwired
Control Options Automatic with manual override
Max Number of Sensors 6
Maximum Current 24 A
Mounting Method Wall Mounted
Voltage 120/240 V

Product Dimensions

Depth 6.562 in / 167 mm
Height 9.125 in / 232 mm
Width 11.5 in / 292 mm

Identifiers

SKU SCP-120
UPC (GTIN-12) 881308020613

Customer Questions & Answers

Premium Snow & Ice Melt Control has 26 Questions and Answers.

Don't see the answer you're looking for? Post your question

How quickly do these systems melt the snow?

That depends on a number of variables (like the temperature outside) but generally speaking these snow melting systems are designed to melt 1" - 3" of snow per hour. Anything above 3" per hour is typically considered blizzard conditions. 

17 people found this helpful.  Did you find this helpful? Yes No

Is it okay to cut the snow melting cable if it is too long for the application for which it was designed?

Never cut the heating cable. A heating cable will not work if it has been cut. If the heating cable is too long, call WarmlyYours to consult with a technician who will guide you in utilizing the additional length of cable.

16 people found this helpful.  Did you find this helpful? Yes No

How does the electric snow melting system compare to hot water tubing (hydronic) systems?

The material costs are similar. However, electric systems are easier to install, with fewer components and significantly lower maintenance costs. Electric systems will run for a shorter period of time to give the same level of performance but with much higher energy efficiency (typically 95%-98% efficient). Controls and sensors required for the two types of systems are very similar. Electric systems do not usually require slab insulation and do not create the concerns typically associated with hydronic systems. These concerns include, but are not limited to, return temperatures, flue gas venting, waterway shrinkage and property damage caused by leaking pipes or tubes.

13 people found this helpful.  Did you find this helpful? Yes No

May I cross or overlap the WarmlyYours snow melt heating cable?

When installing outdoor WarmlyYours snow melting cables for your driveway, patio, walkway, terrace, stairs, ramp, etc. - NEVER cross, overlap, or allow the heating cables to touch each other. Doing so will quickly cause a circuit failure due to excessive heat build up. Always follow the installation instructions and/or design layout plan to ensure the cable is installed with the correct spacing required for proper operation.

12 people found this helpful.  Did you find this helpful? Yes No

Does the factory splice need to be completely embedded during installation?

Yes. The manufacturer's splice that connects the heating element to the cold lead should be entirely embedded in a noncombustible material (like asphalt, concrete, or mortar) within the outdoor surface that is being heated. 

11 people found this helpful.  Did you find this helpful? Yes No

View all 26 Questions and Answers

Customer Reviews

Premium Snow & Ice Melt Control achieved an average rating of 4.5 stars with 2 reviews by our customers.

Have you used this product before? Leave a review

Good product for the price

Mark G., Aston, PA on 01/02/2024

Other than some miscommunication on individual heat cable rolls versus pre-fabricated mats with cables already attached, the installation went pretty well. the control box I ordered was also backordered so needed to go with a more expensive model.

Super simple to use

Anonymous, Elmsdale, NS on 01/07/2021

The controls are super simple to use and I am very happy with the fact it can be remotely controlled using the EMC Interface.

View all customer reviews